Resources

In nuclear fission reactions, mass is converted to energy according to ΔE=Δm⋅c2\Delta E = \Delta m \cdot c^2, whereas classical chemical reactions obey the law of conservation of mass. For the complete combustion of 1.000 mol1.000\text{ mol} of methane: CH4(g)+2O2(g)→CO2(g)+2H2O(l)\text{CH}_4(g) + 2\text{O}_2(g) \rightarrow \text{CO}_2(g) + 2\text{H}_2\text{O}(l), the standard enthalpy of combustion is ΔH∘=−890.3 kJ\Delta H^{\circ} = -890.3\text{ kJ}. (a) Calculate the relativistic mass equivalent Δm\Delta m (in kilograms and micrograms) lost during this chemical reaction using c=3.000×108 m/sc = 3.000 \times 10^8\text{ m/s}. (b) Compare this mass change to the total initial rest mass of the reactants (80.04 g80.04\text{ g}) and explain why macroscopic chemical balances treat the law of conservation of mass as exact.

Answer and steps

Final answer

(a) Δm=∣ΔE∣c2=8.903×105 J(3.000×108 m/s)2=9.892×10−12 kg=9.892×10−6 mg\Delta m = \frac{|\Delta E|}{c^2} = \frac{8.903 \times 10^5\text{ J}}{(3.000 \times 10^8\text{ m/s})^2} = 9.892 \times 10^{-12}\text{ kg} = 9.892 \times 10^{-6}\text{ mg}; (b) Fractional mass loss =9.892×10−12 kg0.08004 kg≈1.236×10−10%= \frac{9.892 \times 10^{-12}\text{ kg}}{0.08004\text{ kg}} \approx 1.236 \times 10^{-10}\% (or ≈1\approx 1 part in 8×1098 \times 10^{9}). Because modern analytical balances have a sensitivity limit of ±10−7 kg\pm 10^{-7}\text{ kg} (0.1 mg0.1\text{ mg}), this mass defect is entirely undetectable, making the classical conservation of mass experimentally exact for all bench chemistry.

Steps

Part (a): Calculate the Relativistic Mass Equivalent Lost (Δm\Delta m)

According to mass-energy equivalence: ΔE=Δm⋅c2  ⟹  Δm=∣ΔE∣c2\Delta E = \Delta m \cdot c^2 \implies \Delta m = \frac{|\Delta E|}{c^2}

  1. Convert the energy released into SI units (Joules): ∣ΔE∣=890.3 kJ=8.903×105 J|\Delta E| = 890.3\text{ kJ} = 8.903 \times 10^5\text{ J}
  2. Substitute ∣ΔE∣|\Delta E| and the speed of light cc into Einstein's relation: Δm=8.903×105 J(3.000×108 m/s)2=8.903×105 kg⋅m2/s29.000×1016 m2/s2=9.892×10−12 kg\Delta m = \frac{8.903 \times 10^5\text{ J}}{(3.000 \times 10^8\text{ m/s})^2} = \frac{8.903 \times 10^5\text{ kg}\cdot\text{m}^2/\text{s}^2}{9.000 \times 10^{16}\text{ m}^2/\text{s}^2} = 9.892 \times 10^{-12}\text{ kg}
  3. Convert mass to smaller metric units:

    • In milligrams (mg\text{mg}): 9.892×10−12 kg×106 mg/kg=9.892×10−6 mg9.892 \times 10^{-12}\text{ kg} \times 10^6\text{ mg/kg} = 9.892 \times 10^{-6}\text{ mg}
    • In micrograms (μg\mu\text{g}): 9.892×10−12 kg×109 μg/kg=9.892×10−3 μg9.892 \times 10^{-12}\text{ kg} \times 10^9\ \mu\text{g/kg} = 9.892 \times 10^{-3}\ \mu\text{g}

Part (b): Compare with Initial Rest Mass and Justify Conservation of Mass

  1. Calculate the fractional and percentage mass loss:

    • Total initial mass of reactants: minitial=80.04 g=0.08004 kgm_{\text{initial}} = 80.04\text{ g} = 0.08004\text{ kg}
    • Fractional mass loss: Fractional mass loss=Δmminitial=9.892×10−12 kg0.08004 kg≈1.236×10−10%(or ≈1 part in 8×109)\text{Fractional mass loss} = \frac{\Delta m}{m_{\text{initial}}} = \frac{9.892 \times 10^{-12}\text{ kg}}{0.08004\text{ kg}} \approx 1.236 \times 10^{-10}\% \quad \left(\text{or } \approx 1\text{ part in } 8 \times 10^9\right)
  2. Physical interpretation and laboratory relevance:

    • Standard analytical laboratory balances have a precision limit around ±0.1 mg\pm 0.1\text{ mg} (±10−4 g\pm 10^{-4}\text{ g} or ±10−7 kg\pm 10^{-7}\text{ kg}), while the most sensitive ultra-microbalances measure down to ≈10−7 g\approx 10^{-7}\text{ g} (10−10 kg10^{-10}\text{ kg}).
    • The mass defect of roughly 10−11 kg10^{-11}\text{ kg} (10−8 g10^{-8}\text{ g}) is far below the detection limit of any macroscopic weighing instrument.
    • Consequently, for all practical chemical benchwork, the total mass before and after a reaction is experimentally indistinguishable, making the classical Law of Conservation of Mass an exceptionally accurate and valid principle in chemical reactions.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to square the speed of light c in the denominator of Einstein's mass-energy formula, resulting in a drastically overestimated mass loss of 2.968 × 10⁻³ kg.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    ΔE=890.3 kJ=890300 J\Delta E = 890.3\text{ kJ} = 890300\text{ J}

  2. Step 2

    Δm=ΔEc=8903003.000×108=2.968×10−3 kg\Delta m = \frac{\Delta E}{c} = \frac{890300}{3.000 \times 10^8} = 2.968 \times 10^{-3}\text{ kg}

    Correct

    Δm=ΔEc2=8.903×105 J(3.000×108 m/s)2=9.892×10−12 kg\Delta m = \frac{\Delta E}{c^2} = \frac{8.903 \times 10^5\text{ J}}{(3.000 \times 10^8\text{ m/s})^2} = 9.892 \times 10^{-12}\text{ kg}

    You divided by cc rather than c2c^2. Rearranging Einstein's equation gives Δm=ΔEc2\Delta m = \frac{\Delta E}{c^2}.

  3. Step 3

    Δm=2.968×10−3 kg×109 μg/kg=2.968×106 μg\Delta m = 2.968 \times 10^{-3}\text{ kg} \times 10^9\ \mu\text{g/kg} = 2.968 \times 10^6\ \mu\text{g}

    Correct

    Δm=9.892×10−12 kg×109 μg/kg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} \times 10^9\ \mu\text{g/kg} = 9.892 \times 10^{-3}\ \mu\text{g}

    You applied the correct conversion factor between kilograms and micrograms (109 μg/kg10^9\ \mu\text{g/kg}), but the value was carried over from the incorrect calculation in the previous step.

  4. Step 4

    Fractional change=2.968×10−3 kg0.08004 kg≈0.0371=3.71%  ⟹  A 3.71% mass loss is easily measurable on modern balances, so mass conservation would not hold macroscopically.\text{Fractional change} = \frac{2.968 \times 10^{-3}\text{ kg}}{0.08004\text{ kg}} \approx 0.0371 = 3.71\% \implies \text{A } 3.71\% \text{ mass loss is easily measurable on modern balances, so mass conservation would not hold macroscopically.}

    Correct

    Fractional mass loss=9.892×10−12 kg0.08004 kg≈1.236×10−10%  ⟹  The mass loss is far below the detection limit of modern balances, so mass is conserved macroscopically.\text{Fractional mass loss} = \frac{9.892 \times 10^{-12}\text{ kg}}{0.08004\text{ kg}} \approx 1.236 \times 10^{-10}\% \implies \text{The mass loss is far below the detection limit of modern balances, so mass is conserved macroscopically.}

    Your comparison method was sound, but substituting the inflated mass led to an unrealistic 3.71%3.71\% mass loss rather than the actual imperceptible ∼10−10%\sim 10^{-10}\% change.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the energy from kilojoules to joules.

You correctly identified and applied the metric conversion factor of 109 μg/kg10^9\ \mu\text{g/kg}.

You set up the ratio between the mass loss and the total initial mass properly.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula rearrangement error

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You omitted the exponent when solving ΔE=Δm⋅c2\Delta E = \Delta m \cdot c^2 for mass, dividing by cc instead of c2c^2. Because cc is on the order of 108 m/s10^8\text{ m/s}, forgetting to square it overestimates the mass equivalent by a factor of 3×1083 \times 10^8.

REASONING PATH
Your ACEpath teacher’s suggested approach
Isolate mass in mass-energy equivalence
  • ΔE=Δm⋅c2  ⟹  Δm=ΔEc2\Delta E = \Delta m \cdot c^2 \implies \Delta m = \frac{\Delta E}{c^2}

  • Check dimensional units: J/(m/s)2=(kg⋅m2/s2)/(m2/s2)=kg\text{J}/(\text{m/s})^2 = (\text{kg}\cdot\text{m}^2/\text{s}^2)/(\text{m}^2/\text{s}^2) = \text{kg}. Dividing by only m/s\text{m/s} yields momentum units (kg⋅m/s)(\text{kg}\cdot\text{m/s}), not mass.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Square the speed of light in the denominator: c2=(3.000×108 m/s)2=9.000×1016 m2/s2c^2 = (3.000 \times 10^8\text{ m/s})^2 = 9.000 \times 10^{16}\text{ m}^2/\text{s}^2.

  2. Calculate the mass equivalent in kilograms: Δm=8.903×105 J9.000×1016 m2/s2=9.892×10−12 kg\Delta m = \frac{8.903 \times 10^5\text{ J}}{9.000 \times 10^{16}\text{ m}^2/\text{s}^2} = 9.892 \times 10^{-12}\text{ kg}.

  3. Convert to micrograms: 9.892×10−12 kg×109 μg/kg=9.892×10−3 μg9.892 \times 10^{-12}\text{ kg} \times 10^9\ \mu\text{g/kg} = 9.892 \times 10^{-3}\ \mu\text{g}.

  4. Compute the fractional mass change: 9.892×10−12 kg0.08004 kg≈1.236×10−10%\frac{9.892 \times 10^{-12}\text{ kg}}{0.08004\text{ kg}} \approx 1.236 \times 10^{-10}\%.

  5. Compare with analytical balance limits: standard analytical balances measure down to 0.1 mg0.1\text{ mg} (10−7 kg10^{-7}\text{ kg}), so a loss of ∼10−11 kg\sim 10^{-11}\text{ kg} cannot be detected, confirming that conservation of mass holds experimentally in chemical reactions.

Final answer

(a) Δm=9.892×10−12 kg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} = 9.892 \times 10^{-3}\ \mu\text{g}; (b) Fractional mass loss ≈1.236×10−10%\approx 1.236 \times 10^{-10}\%, which is far below balance sensitivity (10−7 kg10^{-7}\text{ kg}), so conservation of mass remains experimentally exact.

NEXT STEPS
Final Takeaways from Your Teacher
  • Always write down the formula with units before substituting values to verify that units cancel out to kilograms.

  • Remember that c2≈9×1016 m2/s2c^2 \approx 9 \times 10^{16}\text{ m}^2/\text{s}^2, meaning mass equivalents for ordinary chemical energies are always extraordinarily small (typically <10−9 g< 10^{-9}\text{ g}).

OverviewACEpath Teacher's Diagnosis

02 The student omits the kilo-to-base unit conversion for energy (using kJ instead of J directly with SI units), underestimating the mass loss by a factor of 10³.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Δm=ΔEc2=890.3(3.000×108)2  ⟹  Δm=890.3(9.000×1016)=9.892×10−15 kg\Delta m = \frac{\Delta E}{c^2} = \frac{890.3}{(3.000 \times 10^8)^2} \implies \Delta m = \frac{890.3}{(9.000 \times 10^{16})} = 9.892 \times 10^{-15}\text{ kg}

    Correct

    Δm=∣ΔE∣c2=8.903×105 J(3.000×108 m/s)2=9.892×10−12 kg\Delta m = \frac{|\Delta E|}{c^2} = \frac{8.903 \times 10^5\text{ J}}{(3.000 \times 10^8\text{ m/s})^2} = 9.892 \times 10^{-12}\text{ kg}

    You substituted ΔH∘=890.3\Delta H^{\circ} = 890.3 directly into the equation without converting kilojoules to joules (1 kJ=103 J1\text{ kJ} = 10^3\text{ J}). Because 1 J=1 kg⋅m2/s21\text{ J} = 1\text{ kg}\cdot\text{m}^2/\text{s}^2, the formula requires energy in joules to yield mass in kilograms.

  2. Step 2

    Δm=9.892×10−15 kg×109 μg/kg=9.892×10−6 μg\Delta m = 9.892 \times 10^{-15}\text{ kg} \times 10^9\ \mu\text{g/kg} = 9.892 \times 10^{-6}\ \mu\text{g}

    Correct

    Δm=9.892×10−12 kg×109 μg/kg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} \times 10^9\ \mu\text{g/kg} = 9.892 \times 10^{-3}\ \mu\text{g}

    Your metric conversion factor (109 μg/kg10^9\ \mu\text{g/kg}) and arithmetic were executed properly, but the result carried over the 10−310^{-3} factor error from the previous step.

  3. Step 3

    Fractional mass change=9.892×10−15 kg0.08004 kg=1.236×10−13\text{Fractional mass change} = \frac{9.892 \times 10^{-15}\text{ kg}}{0.08004\text{ kg}} = 1.236 \times 10^{-13}

    Correct

    Fractional mass change=9.892×10−12 kg0.08004 kg≈1.236×10−10\text{Fractional mass change} = \frac{9.892 \times 10^{-12}\text{ kg}}{0.08004\text{ kg}} \approx 1.236 \times 10^{-10}

    You correctly converted 80.04 g80.04\text{ g} to 0.08004 kg0.08004\text{ kg} and divided appropriately, but the ratio was affected by the initial mass defect value.

  4. Step 4

    The mass difference is far below the sensitivity limit of macroscopic balances, making mass appear completely conserved.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified and applied Einstein's relation ΔE=Δm⋅c2\Delta E = \Delta m \cdot c^2.

You accurately converted grams to kilograms when setting up the fractional mass ratio.

You applied the correct unit conversion factor from kilograms to micrograms.

You provided a sound physical justification connecting instrument sensitivity to the conservation of mass.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omitted kilo-to-base unit conversion

You entered 890.3890.3 into the calculation rather than converting 890.3 kJ890.3\text{ kJ} to 8.903×105 J8.903 \times 10^5\text{ J}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Forgetting that derived SI units like the joule (1 J=1 kg⋅m2/s21\text{ J} = 1\text{ kg}\cdot\text{m}^2/\text{s}^2) require base energy in joules when paired with the speed of light in meters per second (c=3.000×108 m/sc = 3.000 \times 10^8\text{ m/s}) to yield kilograms.

REASONING PATH
Your ACEpath teacher’s suggested approach
SI Base Consistency Check
  • In Δm=ΔEc2\Delta m = \frac{\Delta E}{c^2}, ΔE\Delta E must be in joules (J\text{J}), not kilojoules (kJ\text{kJ}), because 1 J=1 kg⋅m2/s21\text{ J} = 1\text{ kg}\cdot\text{m}^2/\text{s}^2.

  • Always multiply values given in kJ\text{kJ} by 10310^3 before substituting into equations with cc.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. ΔE=890.3 kJ=8.903×105 J\Delta E = 890.3\text{ kJ} = 8.903 \times 10^5\text{ J}

  2. Δm=8.903×105 J(3.000×108 m/s)2=9.892×10−12 kg\Delta m = \frac{8.903 \times 10^5\text{ J}}{(3.000 \times 10^8\text{ m/s})^2} = 9.892 \times 10^{-12}\text{ kg}

  3. Δm=9.892×10−12 kg×109 μg/kg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} \times 10^9\ \mu\text{g/kg} = 9.892 \times 10^{-3}\ \mu\text{g}

  4. Fractional mass change=9.892×10−12 kg0.08004 kg≈1.236×10−10\text{Fractional mass change} = \frac{9.892 \times 10^{-12}\text{ kg}}{0.08004\text{ kg}} \approx 1.236 \times 10^{-10} (or 1.236×10−8%1.236 \times 10^{-8}\%)

Final answer

(a) Δm=9.892×10−12 kg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} = 9.892 \times 10^{-3}\ \mu\text{g}; (b) Fractional mass loss ≈1.236×10−10\approx 1.236 \times 10^{-10} (1.236×10−8%1.236 \times 10^{-8}\%). The mass defect is far below the sensitivity limit of analytical balances (∼10−7 kg\sim 10^{-7}\text{ kg}), making mass conservation experimentally exact.

NEXT STEPS
Final Takeaways from Your Teacher
  • Always explicitly write unit tags next to values during substitution (e.g., write kJ\text{kJ} vs J\text{J}) to catch missing prefix conversions before computing.

  • Verify that your energy unit breaks down cleanly to kg⋅m2/s2\text{kg}\cdot\text{m}^2/\text{s}^2 whenever calculating mass from c2c^2.

OverviewACEpath Teacher's Diagnosis

03 The student uses an incorrect conversion factor of 10⁶ μg/kg instead of 10⁹ μg/kg, miscalculating the mass loss in micrograms as 9.892 × 10⁻⁶ μg.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    ΔE=890.3 kJ=8.903×105 J  ⟹  Δm=8.903×105(3.000×108)2=9.892×10−12 kg\Delta E = 890.3\text{ kJ} = 8.903 \times 10^5\text{ J} \implies \Delta m = \frac{8.903 \times 10^5}{(3.000 \times 10^8)^2} = 9.892 \times 10^{-12}\text{ kg}

  2. Step 2

    Δm=9.892×10−12 kg×106 μg/kg=9.892×10−6 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} \times 10^6\ \mu\text{g/kg} = 9.892 \times 10^{-6}\ \mu\text{g}

    Correct

    Δm=9.892×10−12 kg×109 μg/kg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} \times 10^9\ \mu\text{g/kg} = 9.892 \times 10^{-3}\ \mu\text{g}

    You used the metric conversion factor 10610^6 (which converts kilograms to milligrams, mg\text{mg}) instead of 109 μg/kg10^9\ \mu\text{g/kg} for micrograms.

  3. Step 3

    Ratio=9.892×10−12 kg0.08004 kg=1.236×10−10\text{Ratio} = \frac{9.892 \times 10^{-12}\text{ kg}}{0.08004\text{ kg}} = 1.236 \times 10^{-10}

  4. Step 4

    The mass loss is too minuscule to be detected by standard chemical balances, so conservation of mass holds experimentally.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the enthalpy change from kilojoules to Joules.

You correctly used Einstein's equation to determine the mass equivalent in kilograms.

You correctly calculated the ratio of lost mass to total initial reactant mass.

You accurately explained why laboratory balances treat mass conservation as exact.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Metric prefix confusion (milli- vs. micro-)

You substituted 10610^6 instead of 10910^9 when converting from kilograms to micrograms, confusing milligrams with micrograms.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the SI metric prefixes milli- (10−3 g=10−6 kg10^{-3}\text{ g} = 10^{-6}\text{ kg}) and micro- (10−6 g=10−9 kg10^{-6}\text{ g} = 10^{-9}\text{ kg}) when converting directly from kilograms.

REASONING PATH
Your ACEpath teacher’s suggested approach
Two-step SI prefix conversion
  • Convert through the base unit (grams): 1 kg=103 g1\text{ kg} = 10^3\text{ g}, and 1 g=106 μg1\text{ g} = 10^6\ \mu\text{g}, so 1 kg=109 μg1\text{ kg} = 10^9\ \mu\text{g}.

  • When converting between non-base units with prefixes, convert to grams first or multiply power factors: 103×106=109 μg/kg10^3 \times 10^6 = 10^9\ \mu\text{g/kg}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Multiply Δm=9.892×10−12 kg\Delta m = 9.892 \times 10^{-12}\text{ kg} by the correct microgram conversion factor: (103 g1 kg)(106 μg1 g)=109 μg/kg\left(\frac{10^3\text{ g}}{1\text{ kg}}\right) \left(\frac{10^6\ \mu\text{g}}{1\text{ g}}\right) = 10^9\ \mu\text{g/kg}.

  2. Calculate: Δm=9.892×10−12×109 μg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12} \times 10^9\ \mu\text{g} = 9.892 \times 10^{-3}\ \mu\text{g}.

Final answer

(a) Δm=9.892×10−12 kg=9.892×10−3 μg\Delta m = 9.892 \times 10^{-12}\text{ kg} = 9.892 \times 10^{-3}\ \mu\text{g}; (b) Fractional mass loss is 1.236×10−101.236 \times 10^{-10} (1.236×10−8%1.236 \times 10^{-8}\%), which is undetectable on chemical balances, confirming experimental conservation of mass.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review metric prefixes from kilo- (10310^3) down through milli- (10−310^{-3}), micro- (10−610^{-6}), and nano- (10−910^{-9}).

  • Practice converting values from kilograms directly to milligrams, micrograms, and nanograms via dimensional analysis.

Lock it in

Similar question

01

The explosion of 1.00 mol1.00\text{ mol} of TNT releases approximately 4.60×106 J4.60 \times 10^6\text{ J} of energy. Calculate the mass equivalent Δm\Delta m (in kg\text{kg}) lost during this process using c=3.00×108 m/sc = 3.00 \times 10^8\text{ m/s}.

Answer

Δm=ΔEc2=4.60×106 J(3.00×108 m/s)2=4.60×1069.00×1016=5.11×10−11 kg\Delta m = \frac{\Delta E}{c^2} = \frac{4.60 \times 10^6\text{ J}}{(3.00 \times 10^8\text{ m/s})^2} = \frac{4.60 \times 10^6}{9.00 \times 10^{16}} = 5.11 \times 10^{-11}\text{ kg}.

02

In a hypothetical reaction, a system loses 1.80×10−10 kg1.80 \times 10^{-10}\text{ kg} of mass as heat. Calculate the total energy released ΔE\Delta E in kilojoules (kJ\text{kJ}) using c=3.00×108 m/sc = 3.00 \times 10^8\text{ m/s}.

Answer

ΔE=Δm⋅c2=(1.80×10−10 kg)×(9.00×1016 m2/s2)=1.62×107 J=1.62×104 kJ\Delta E = \Delta m \cdot c^2 = (1.80 \times 10^{-10}\text{ kg}) \times (9.00 \times 10^{16}\text{ m}^2/\text{s}^2) = 1.62 \times 10^7\text{ J} = 1.62 \times 10^4\text{ kJ}.

03

A chemical reaction involving 500.0 g500.0\text{ g} of total reactants produces 2.50×103 kJ2.50 \times 10^3\text{ kJ} of heat. (a) Find the lost mass Δm\Delta m in nanograms (ng\text{ng}). (b) Determine the fractional percentage mass change and explain whether a microbalance sensitive to 1 μg1\ \mu\text{g} (1000 ng1000\text{ ng}) can detect this change.

Answer

(a) Δm=2.50×106 J9.00×1016 m2/s2=2.78×10−11 kg=0.0278 ng\Delta m = \frac{2.50 \times 10^6\text{ J}}{9.00 \times 10^{16}\text{ m}^2/\text{s}^2} = 2.78 \times 10^{-11}\text{ kg} = 0.0278\text{ ng}. (b) Fractional percentage mass loss is 2.78×10−11 kg0.5000 kg×100%=5.56×10−9%\frac{2.78 \times 10^{-11}\text{ kg}}{0.5000\text{ kg}} \times 100\% = 5.56 \times 10^{-9}\%. Because 0.0278 ng≪1000 ng0.0278\text{ ng} \ll 1000\text{ ng}, the mass loss is completely undetectable on the microbalance.

Loading workspace…