Resources
An industrial bio-ethanol distillation column processes a fermented broth stream fed at a rate of . The analytical assay of the feed indicates an ethanol concentration of with a broth density of . The distillation overhead stream recovers of the total feed ethanol at a commercial purity of ethanol (density ). The reboiler supplies saturated process steam at an energy intensity of per kilogram of recovered pure ethanol. Determine: (a) the volumetric flow rate of the recovered commercial ethanol product in , and (b) the thermal power requirement of the reboiler expressed in megawatts ().
Answer and steps
Final answer
(a) ; (b) .
Steps
Calculate the Mass Flow Rate of Ethanol in the Feed Stream
The feed stream enters at a volumetric flow rate of:
With an analytical concentration of , the mass flow rate of pure ethanol entering the column, , is:
(Note: The total broth density is provided as background physical property data, but it is not needed here because the ethanol content is already specified per unit volume).
Determine the Mass and Volume of Recovered Ethanol Product (Part a)
The distillation column achieves a recovery efficiency of for ethanol:
The overhead product is not anhydrous; it contains ethanol. Therefore, the total mass flow rate of the commercial overhead stream, , is:
Using the product density , the volumetric flow rate of the product stream is:
Determine the Reboiler Thermal Power Requirement (Part b)
The reboiler requires of thermal energy per kilogram of pure ethanol recovered.
Calculate the total hourly energy demand:
Convert this energy rate into thermal power (megawatts, where ):
Typical errors
01 The student misinterprets 95.6 wt% as volume percent and directly multiplies the recovered ethanol volume by 0.956 instead of dividing the mass by the mass fraction.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
Because ethanol makes up of the commercial product, the total product stream must weigh more than the pure ethanol it contains. By definition, , which means you must divide by rather than multiply.
- Step 4Correct
Your formula for converting product mass flow rate to volumetric flow rate using density was correct, but the numerical answer was affected by the mass flow rate calculated in Step 3.
- Step 5
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the feed mass flow rate of pure ethanol using the feed volume and analytical concentration.
You applied the distillation recovery factor correctly to get the recovered pure ethanol mass flow rate.
You calculated the reboiler thermal power in part (b) with perfect unit conversions.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou set instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the part-to-whole relationship when working with mass fractions. A mixture containing an impure component always has a total mass greater than or equal to the mass of the pure component.
REASONING PATH
Your ACEpath teacher’s suggested approach- Sanity Check Mixture vs. Pure Mass
For any component with mass fraction , .
Whenever you solve for total stream mass from a pure component mass, divide by the weight fraction: .
CORRECTED PATH
ACEpath Teacher's Demonstration(a) ; (b)
02 The student calculates the reboiler thermal duty using the total feed ethanol mass rate instead of the recovered pure ethanol mass rate.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3
- Step 4
3712.5, = 3712.5, 3.25, = 12065.625, = 12065.625, / 3600, = 3.35,
Correct\dot{Q} = 3.15,
You based the energy demand on the total feed ethanol () rather than the recovered pure ethanol () as specified in the problem statement.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly computed the volumetric feed rate and the entering ethanol mass flow rate.
You accurately calculated the recovered mass of pure ethanol using the separation recovery factor.
You correctly accounted for the commercial purity and stream density to find the product volumetric flow rate.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou selected the feed mass flow rate instead of the recovered product mass flow rate as the basis for the specific energy consumption metric. Industrial energy intensity figures are usually defined per unit of target product recovered or produced unless explicitly stated on a raw-feed basis.
REASONING PATH
Your ACEpath teacher’s suggested approach- Verify Specific Energy Basis
Specific energy metrics () must be multiplied by the exact reference stream specified in the problem (e.g., product stream vs. feed stream).
Highlight the denominator units in the energy intensity statement (here, 'per kilogram of recovered pure ethanol') before selecting the mass flow rate to multiply.
CORRECTED PATH
ACEpath Teacher's DemonstrationMultiply the specific energy intensity () by the recovered pure ethanol rate: .
Convert the hourly thermal duty into megawatts: .
(a) ; (b)
03 The student omits the 94.0% recovery factor when determining the overhead ethanol stream, assuming 100% recovery.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You assumed 100% of the fed ethanol is recovered in the overhead product. The column achieves a 94.0% recovery efficiency, so you need to multiply the feed ethanol mass flow rate by .
- Step 3Correct
Your formulas for converting pure component mass to commercial product mass and then to volumetric flow rate are completely correct, but the numerical result is affected by using instead of .
- Step 4Correct
Your method for calculating hourly thermal energy demand and converting it to megawatts is sound, but this step carries forward the unadjusted feed ethanol rate.
WHAT YOU DID WELL
Compliments from Your TeacherYou accurately converted to and computed the feed ethanol mass rate.
You correctly used the weight fraction to relate pure component mass to total product stream mass.
You converted units of energy per hour to megawatts correctly by dividing by .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou equated the recovered ethanol mass directly to the feed ethanol mass.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisIn industrial separations, fractional recovery (yield to overhead) and product purity (concentration in overhead) are distinct parameters; recovery determines how much of the target component exits in that stream before purity is applied.
REASONING PATH
Your ACEpath teacher’s suggested approach- Distinguish Recovery from Purity
Always multiply the entering target mass by the specified split or recovery factor before dividing by the product weight fraction.
CORRECTED PATH
ACEpath Teacher's Demonstration(a) ; (b)
Lock it in
How do you calculate total mixture mass () when given pure component mass () and weight fraction ()?
. The whole is always larger than the part, so dividing by increases the value.
Similar question
A crystallization process recovers of pure citric acid in a wet cake stream that contains citric acid. What is the total mass flow rate of the wet cake stream?
Answer
.
A bio-refinery stream contains of recovered isopropanol. It is formulated as an aqueous disinfectant containing isopropanol with a density of . Calculate the volumetric flow rate of the disinfectant in .
Answer
- Total mass flow rate: .\n2. Volumetric flow rate: .
A fermentation broth of has a lactic acid concentration of . A membrane separation unit recovers of the lactic acid as an commercial aqueous solution (density ). Determine the volumetric flow rate of the commercial lactic acid product in .
Answer
- Lactic acid fed: .\n2. Pure lactic acid recovered: .\n3. Total product mass: .\n4. Volumetric flow rate: .