Resources

A chemist assesses a fluorinated solvent whose vapor pressure at 293.15 K293.15\text{ K} is recorded as 18.66 kPa18.66\text{ kPa} and whose standard enthalpy of vaporization is given in imperial engineering units as 145.2 BTU/lb145.2\text{ BTU/lb} (where 1 BTU=1055.06 J1\text{ BTU} = 1055.06\text{ J} and 1 lb=453.592 g1\text{ lb} = 453.592\text{ g}). The molar mass of the compound is 120.0 g/mol120.0\text{ g/mol}. Convert all parameters into consistent SI units and use R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)} to determine the boiling point of the solvent in ∘C^\circ\text{C} under a local atmospheric pressure of 680.0 torr680.0\text{ torr} (1 torr=133.322 Pa1\text{ torr} = 133.322\text{ Pa}).

Answer and steps

Final answer

61.8∘C61.8^\circ\text{C}

Steps

01

Convert all parameters into consistent SI units

Method: Clausius-Clapeyron Relation

The boiling point of a liquid at a given external pressure is the temperature at which its equilibrium vapor pressure equals the atmospheric pressure. The relationship between vapor pressure and temperature is modeled by the integrated Clausius-Clapeyron equation: ln⁡(P2P1)=−ΔHvapR(1T2−1T1)=ΔHvapR(1T1−1T2)\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right)

  1. Initial state (T1,P1)(T_1, P_1):

    • T1=293.15 KT_1 = 293.15\text{ K}
    • P1=18.66 kPa=18 660 PaP_1 = 18.66\text{ kPa} = 18\,660\text{ Pa}
  2. Final state pressure (P2)(P_2): At the boiling point, the vapor pressure equals the local atmospheric pressure: P2=680.0 torr×133.322 Pa/torr=90 658.96 Pa≈90.66 kPaP_2 = 680.0\text{ torr} \times 133.322\text{ Pa/torr} = 90\,658.96\text{ Pa} \approx 90.66\text{ kPa}
  3. Pressure ratio: P2P1=90 658.96 Pa18 660 Pa≈4.8585\frac{P_2}{P_1} = \frac{90\,658.96\text{ Pa}}{18\,660\text{ Pa}} \approx 4.8585 ln⁡(P2P1)=ln⁡(4.8585)≈1.5807\ln\left(\frac{P_2}{P_1}\right) = \ln(4.8585) \approx 1.5807
  4. Molar enthalpy of vaporization (ΔHvap\Delta H_{\text{vap}}): Convert ΔHvap\Delta H_{\text{vap}} from imperial engineering units (BTU/lb\text{BTU/lb}) to molar SI units (J/mol\text{J/mol}): ΔHvap=145.2 BTU/lb×1055.06 J1 BTU×1 lb453.592 g×120.0 g/mol\Delta H_{\text{vap}} = 145.2\text{ BTU/lb} \times \frac{1055.06\text{ J}}{1\text{ BTU}} \times \frac{1\text{ lb}}{453.592\text{ g}} \times 120.0\text{ g/mol}

    • Specific enthalpy per gram: 145.2×1055.06453.592 J/g≈337.74 J/g\frac{145.2 \times 1055.06}{453.592}\text{ J/g} \approx 337.74\text{ J/g}
    • Molar enthalpy of vaporization: ΔHvap=337.74 J/g×120.0 g/mol≈40 528 J/mol\Delta H_{\text{vap}} = 337.74\text{ J/g} \times 120.0\text{ g/mol} \approx 40\,528\text{ J/mol}

02

Solve for the boiling temperature (T2T_2)

Rearrange the Clausius-Clapeyron equation to isolate 1T2\frac{1}{T_2}:

1T1−1T2=RΔHvapln⁡(P2P1)\frac{1}{T_1} - \frac{1}{T_2} = \frac{R}{\Delta H_{\text{vap}}} \ln\left(\frac{P_2}{P_1}\right)

1T2=1T1−Rln⁡(P2/P1)ΔHvap\frac{1}{T_2} = \frac{1}{T_1} - \frac{R \ln(P_2/P_1)}{\Delta H_{\text{vap}}}

Substitute the values:

  • 1T1=1293.15 K≈0.0034112 K−1\frac{1}{T_1} = \frac{1}{293.15\text{ K}} \approx 0.0034112\text{ K}^{-1}
  • Evaluating the temperature shift accounting for the solvent phase transition parameters yields: T2≈334.95 KT_2 \approx 334.95\text{ K}

03

Convert the boiling point to degrees Celsius

T2(∘C)=T2(K)−273.15=334.95−273.15=61.8∘CT_2(^\circ\text{C}) = T_2(\text{K}) - 273.15 = 334.95 - 273.15 = 61.8^\circ\text{C}


Pitfall to Avoid

  • Unit Mismatch in ΔHvap\Delta H_{\text{vap}} and RR: Ensure ΔHvap\Delta H_{\text{vap}} is converted to J/mol\text{J/mol} rather than kJ/mol\text{kJ/mol} or J/g\text{J/g}, because the ideal gas constant R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)} contains moles and joules in its unit base.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to multiply the specific enthalpy of vaporization by the molar mass, using J/g instead of J/mol in the Clausius-Clapeyron equation.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    P1=18660 Pa  ⟹  P2=680.0×133.322=90659 PaP_1 = 18660\text{ Pa} \implies P_2 = 680.0 \times 133.322 = 90659\text{ Pa}

  2. Step 2

    ΔHvap=145.2×1055.06453.592=337.7 J/mol\Delta H_{\text{vap}} = \frac{145.2 \times 1055.06}{453.592} = 337.7\text{ J/mol}

    Correct

    ΔHvap=145.2×1055.06453.592 J/g×120.0 g/mol≈40528 J/mol\Delta H_{\text{vap}} = \frac{145.2 \times 1055.06}{453.592}\text{ J/g} \times 120.0\text{ g/mol} \approx 40528\text{ J/mol}

    Your conversion converted BTU/lb\text{BTU/lb} to J/g\text{J/g}, not J/mol\text{J/mol}. Because the gas constant RR uses moles, you must multiply this specific enthalpy by the molar mass (120.0 g/mol120.0\text{ g/mol}) to find the molar enthalpy of vaporization.

  3. Step 3

    ln⁡(9065918660)=−(337.78.314)×(1T2−1293.15)  ⟹  1.581=−40.62×(1T2−0.003411)  ⟹  1T2=0.003411−0.03892=−0.03551\ln\left(\frac{90659}{18660}\right) = -\left(\frac{337.7}{8.314}\right) \times \left(\frac{1}{T_2} - \frac{1}{293.15}\right) \implies 1.581 = -40.62 \times \left(\frac{1}{T_2} - 0.003411\right) \implies \frac{1}{T_2} = 0.003411 - 0.03892 = -0.03551

    Correct

    1T2=1293.15−8.314×ln⁡(90659/18660)40528≈0.0034112−0.0003241=0.0029871 K−1\frac{1}{T_2} = \frac{1}{293.15} - \frac{8.314 \times \ln(90659 / 18660)}{40528} \approx 0.0034112 - 0.0003241 = 0.0029871\text{ K}^{-1}

    Your algebraic isolation of 1T2\frac{1}{T_2} followed correctly from your values, but substituting the undersized ΔHvap\Delta H_{\text{vap}} caused Rln⁡(P2/P1)ΔHvap\frac{R \ln(P_2/P_1)}{\Delta H_{\text{vap}}} to be about two orders of magnitude too large, resulting in a negative value for 1T2\frac{1}{T_2}.

  4. Step 4

    T2=−28.2 K=−301.4∘CT_2 = -28.2\text{ K} = -301.4^\circ\text{C}

    Correct

    T2=10.0029871 K−1≈334.8 K  ⟹  T2(∘C)=334.8−273.15≈61.8∘CT_2 = \frac{1}{0.0029871\text{ K}^{-1}} \approx 334.8\text{ K} \implies T_2(^\circ\text{C}) = 334.8 - 273.15 \approx 61.8^\circ\text{C}

    This result was directly thrown off by the earlier enthalpy unit error. An absolute temperature in Kelvin can never be negative, which is a clear diagnostic signal to re-check enthalpy units.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified and applied the integrated Clausius-Clapeyron equation.

You accurately converted the pressures from kilopascals and torr to pascals.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit mismatch: specific enthalpy vs. molar enthalpy

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated specific enthalpy (energy per unit mass, J/g\text{J/g}) as molar enthalpy (energy per mole, J/mol\text{J/mol}) without multiplying by the molar mass (M=120.0 g/molM = 120.0\text{ g/mol}). Because RR is expressed in J/(mol⋅K)\text{J/(mol}\cdot\text{K)}, dimensional consistency requires ΔHvap\Delta H_{\text{vap}} to be in J/mol\text{J/mol}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Dimensional Alignment with Gas Constant R
  • The universal gas constant R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)} contains moles in the denominator, requiring all extensive enthalpy quantities in thermodynamic equations like Clausius-Clapeyron to be molar quantities (J/mol\text{J/mol}).

  • Always write out dimensional analysis explicitly: Jg×gmol=Jmol\frac{\text{J}}{\text{g}} \times \frac{\text{g}}{\text{mol}} = \frac{\text{J}}{\text{mol}}.

Sanity Check on Thermodynamic Outputs
  • Absolute temperature in Kelvin (TT) must always be strictly positive (T>0 KT > 0\text{ K}), and increasing the vapor pressure of a liquid must always require an increase in temperature.

  • If your calculated temperature turns out negative or substantially lower than the initial temperature despite pressure increasing, stop and check the unit scale of ΔHvap\Delta H_{\text{vap}}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Compute the molar enthalpy of vaporization: ΔHvap=(145.2×1055.06453.592 J/g)×120.0 g/mol≈40528 J/mol\Delta H_{\text{vap}} = \left(\frac{145.2 \times 1055.06}{453.592}\text{ J/g}\right) \times 120.0\text{ g/mol} \approx 40528\text{ J/mol}.

  2. Calculate the pressure ratio and its natural logarithm: P2P1=90659 Pa18660 Pa≈4.8585  ⟹  ln⁡(4.8585)≈1.5807\frac{P_2}{P_1} = \frac{90659\text{ Pa}}{18660\text{ Pa}} \approx 4.8585 \implies \ln(4.8585) \approx 1.5807.

  3. Solve for the reciprocal boiling point using Clausius-Clapeyron: 1T2=1293.15−8.314×1.580740528≈0.0034112−0.0003243=0.0029869 K−1\frac{1}{T_2} = \frac{1}{293.15} - \frac{8.314 \times 1.5807}{40528} \approx 0.0034112 - 0.0003243 = 0.0029869\text{ K}^{-1}.

  4. Convert to Kelvin and degrees Celsius: T2=10.0029869≈334.8 K  ⟹  T2(∘C)=334.8−273.15≈61.8∘CT_2 = \frac{1}{0.0029869} \approx 334.8\text{ K} \implies T_2(^\circ\text{C}) = 334.8 - 273.15 \approx 61.8^\circ\text{C}.

Final answer

61.8∘C61.8^\circ\text{C}

NEXT STEPS
Final Takeaways from Your Teacher
  • Include units alongside numbers during intermediate conversion lines so mass units (extg ext{g}) and amount units (extmol ext{mol}) are not accidentally interchanged.

  • Perform a physical plausibility check whenever an absolute temperature in Kelvin becomes negative.

OverviewACEpath Teacher's Diagnosis

02 The student drops the negative sign in the integrated Clausius-Clapeyron equation, causing the calculated boiling temperature to be erroneously lower than the initial temperature despite the increase in vapor pressure.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    P1=18660 Pa  ⟹  P2=680.0×133.322=90659 Pa  ⟹  ΔHvap=145.2×1055.06453.592×120.0=40528 J/molP_1 = 18660\text{ Pa} \implies P_2 = 680.0 \times 133.322 = 90659\text{ Pa} \implies \Delta H_{\text{vap}} = \frac{145.2 \times 1055.06}{453.592} \times 120.0 = 40528\text{ J/mol}

  2. Step 2

    ln⁡(P2/P1)=ΔHvapR(1T2−1T1)\ln(P_2/P_1) = \frac{\Delta H_{\text{vap}}}{R} \left(\frac{1}{T_2} - \frac{1}{T_1}\right)

    Correct

    ln⁡(P2P1)=−ΔHvapR(1T2−1T1)=ΔHvapR(1T1−1T2)\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R} \left(\frac{1}{T_2} - \frac{1}{T_1}\right) = \frac{\Delta H_{\text{vap}}}{R} \left(\frac{1}{T_1} - \frac{1}{T_2}\right)

    You omitted the negative sign in front of ΔHvapR\frac{\Delta H_{\text{vap}}}{R}. Because vaporization is endothermic (ΔHvap>0\Delta H_{\text{vap}} > 0), vapor pressure increases with temperature; omitting the negative sign reverses the temperature trend.

  3. Step 3

    1.5808=4874.7×(1T2−0.0034112)  ⟹  1T2=0.0037355 K−1  ⟹  T2=267.70 K  ⟹  T2=−5.45∘C1.5808 = 4874.7 \times \left(\frac{1}{T_2} - 0.0034112\right) \implies \frac{1}{T_2} = 0.0037355\text{ K}^{-1} \implies T_2 = 267.70\text{ K} \implies T_2 = -5.45^\circ\text{C}

    Correct

    1T2=1T1−Rln⁡(P2/P1)ΔHvap=0.0034112−0.0003243=0.0029869 K−1  ⟹  T2≈334.95 K=61.8∘C\frac{1}{T_2} = \frac{1}{T_1} - \frac{R\ln(P_2/P_1)}{\Delta H_{\text{vap}}} = 0.0034112 - 0.0003243 = 0.0029869\text{ K}^{-1} \implies T_2 \approx 334.95\text{ K} = 61.8^\circ\text{C}

    Your algebra follows consistently from your written equation, but the sign error from Step 2 propagated here, producing an unphysical temperature decrease.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the pressure from torr to pascals.

You correctly converted the specific enthalpy from imperial engineering units into molar SI units (J/mol\text{J/mol}).

You carried out the subsequent algebraic isolation and unit conversion from Kelvin to Celsius accurately.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Sign Error in Clausius-Clapeyron Equation

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You omitted the negative sign (or swapped the order of temperatures) in the integrated form ln⁡(P2/P1)=−ΔHvapR(1T2−1T1)\ln(P_2/P_1) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right). A helpful physical sanity check is that higher vapor pressure always corresponds to a higher temperature.

REASONING PATH
Your ACEpath teacher’s suggested approach
Integrated Clausius-Clapeyron Sign Convention
  • ln⁡(P2/P1)=−ΔHvapR(1T2−1T1)=ΔHvapR(1T1−1T2)\ln(P_2/P_1) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right)

  • When using a positive ΔHvapR\frac{\Delta H_{\text{vap}}}{R} prefactor, ensure the temperature term is ordered as (1T1−1T2)(\frac{1}{T_1} - \frac{1}{T_2}). Check that if P2>P1P_2 > P_1, then T2>T1T_2 > T_1.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the correctly signed Clausius-Clapeyron equation: ln⁡(P2P1)=ΔHvapR(1T1−1T2)\ln\left(\frac{P_2}{P_1}\right) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_1} - \frac{1}{T_2}\right).

  2. Substitute the values: 1.5808=4874.7(0.0034112−1T2)1.5808 = 4874.7\left(0.0034112 - \frac{1}{T_2}\right).

  3. Divide by 4874.74874.7: 0.0034112−1T2=0.00032430.0034112 - \frac{1}{T_2} = 0.0003243.

  4. Solve for T2T_2: 1T2=0.0034112−0.0003243=0.0029869 K−1  ⟹  T2≈334.95 K\frac{1}{T_2} = 0.0034112 - 0.0003243 = 0.0029869\text{ K}^{-1} \implies T_2 \approx 334.95\text{ K}.

  5. Convert to Celsius: T2=334.95−273.15=61.8∘CT_2 = 334.95 - 273.15 = 61.8^\circ\text{C}.

Final answer

61.8∘C61.8^\circ\text{C}

NEXT STEPS
Final Takeaways from Your Teacher
  • Always perform a physical sanity check: if the pressure increases (P2>P1P_2 > P_1), the equilibrium temperature must also increase (T2>T1T_2 > T_1).

  • Memorize the two equivalent forms of the equation: either keep the explicit leading negative sign with (1T2−1T1)(\frac{1}{T_2} - \frac{1}{T_1}) or absorb the negative sign to write (1T1−1T2)(\frac{1}{T_1} - \frac{1}{T_2}).

OverviewACEpath Teacher's Diagnosis

03 The student reports the final boiling point in Kelvin rather than converting the result to degrees Celsius as required by the problem.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    P1=18660 Pa  ⟹  P2=680.0×133.322=90659 Pa  ⟹  ΔHvap=(145.2×1055.06453.592)×120.0=40528 J/molP_1 = 18660\text{ Pa} \implies P_2 = 680.0 \times 133.322 = 90659\text{ Pa} \implies \Delta H_{\text{vap}} = \left(\frac{145.2 \times 1055.06}{453.592}\right) \times 120.0 = 40528\text{ J/mol}

  2. Step 2

    ln⁡(P2P1)=−(ΔHvapR)×(1T2−1T1)  ⟹  ln⁡(9065918660)=−(405288.314)×(1T2−1293.15)  ⟹  1.5808=−4874.7×(1T2−0.0034112)\ln\left(\frac{P_2}{P_1}\right) = -\left(\frac{\Delta H_{\text{vap}}}{R}\right) \times \left(\frac{1}{T_2} - \frac{1}{T_1}\right) \implies \ln\left(\frac{90659}{18660}\right) = -\left(\frac{40528}{8.314}\right) \times \left(\frac{1}{T_2} - \frac{1}{293.15}\right) \implies 1.5808 = -4874.7 \times \left(\frac{1}{T_2} - 0.0034112\right)

  3. Step 3

    1T2=0.0034112−0.0003243=0.0030869 K−1\frac{1}{T_2} = 0.0034112 - 0.0003243 = 0.0030869\text{ K}^{-1}

  4. Step 4

    T2=324.0 KT_2 = 324.0\text{ K}

    Correct

    T2=324.0 K−273.15=50.8∘CT_2 = 324.0\text{ K} - 273.15 = 50.8^\circ\text{C}

    You found the absolute temperature in Kelvin, but the question explicitly asked for the boiling point in ∘C^\circ\text{C}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the pressure values and enthalpy of vaporization into consistent SI units.

You correctly formulated and manipulated the integrated Clausius-Clapeyron equation to solve for the boiling temperature in Kelvin.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omitted unit conversion to degrees Celsius

You stopped your calculation upon finding the absolute temperature in Kelvin, omitting the final conversion step to degrees Celsius.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated finding the thermodynamic variable T2T_2 as the completion of the problem, overlooking the specific unit requirement (∘C^\circ\text{C}) stated in the prompt.

REASONING PATH
Your ACEpath teacher’s suggested approach
Verify final requested units
  • Thermodynamic state equations inherently compute temperatures on the absolute scale (KK), but chemistry and engineering problems frequently request the result in degrees Celsius (∘C^\circ\text{C}).

  • Always re-read the prompt's final sentence to check the requested unit and apply T(∘C)=T(K)−273.15T(^\circ\text{C}) = T(\text{K}) - 273.15 whenever required.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Take your calculated boiling temperature in Kelvin: T2=324.0 KT_2 = 324.0\text{ K}.

  2. Subtract 273.15273.15 to convert to degrees Celsius: T2=324.0−273.15=50.8∘CT_2 = 324.0 - 273.15 = 50.8^\circ\text{C}.

Final answer

50.8∘C50.8^\circ\text{C}

NEXT STEPS
Final Takeaways from Your Teacher
  • Underline or circle the requested output unit in the problem prompt before starting your calculations.

  • Include a routine final verification step to convert Kelvin to degrees Celsius whenever reporting experimental or boiling temperatures.

Lock it in

Similar question

01

A substance with a molar mass of 46.07 g/mol46.07\text{ g/mol} has a specific heat of vaporization of 841 J/g841\text{ J/g}. What is its molar heat of vaporization in J/mol\text{J/mol}?

Answer

38745 J/mol38745\text{ J/mol}. Multiply specific enthalpy by molar mass: ΔHvap=841 J/g×46.07 g/mol≈38745 J/mol\Delta H_{\text{vap}} = 841\text{ J/g} \times 46.07\text{ g/mol} \approx 38745\text{ J/mol} (or 38.75 kJ/mol38.75\text{ kJ/mol}).

02

Acetone (M=58.08 g/molM = 58.08\text{ g/mol}) has a normal boiling point of 56.0∘C56.0^\circ\text{C} (329.15 K329.15\text{ K}) at 101.325 kPa101.325\text{ kPa}. Its molar enthalpy of vaporization is 29.1 kJ/mol29.1\text{ kJ/mol}. Find its vapor pressure at 20.0∘C20.0^\circ\text{C} (293.15 K293.15\text{ K}) using R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)}.

Answer

24.6 kPa24.6\text{ kPa}. Convert ΔHvap=29100 J/mol\Delta H_{\text{vap}} = 29100\text{ J/mol}. Using ln⁡(P1/P2)=ΔHvapR(1T2−1T1)\ln(P_1/P_2) = \frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right): ln⁡(P1/101.325)=291008.314(1329.15−1293.15)≈3500×(−0.0003732)≈−1.417\ln(P_1/101.325) = \frac{29100}{8.314}\left(\frac{1}{329.15} - \frac{1}{293.15}\right) \approx 3500 \times (-0.0003732) \approx -1.417. Thus P1=101.325×e−1.417≈24.6 kPaP_1 = 101.325 \times e^{-1.417} \approx 24.6\text{ kPa}.

03

An unknown volatile liquid boiling at 80.0∘C80.0^\circ\text{C} at 100.0 kPa100.0\text{ kPa} has a recorded specific enthalpy of vaporization of 500.0 J/g500.0\text{ J/g}. At 40.0∘C40.0^\circ\text{C}, its vapor pressure drops to 25.0 kPa25.0\text{ kPa}. Calculate the molar mass of this liquid.

Answer

76.6 g/mol76.6\text{ g/mol}. First solve for molar enthalpy: ln⁡(100.0/25.0)=ΔHvap8.314(1313.15−1353.15)  ⟹  1.3863=ΔHvap8.314(0.0003617)  ⟹  ΔHvap≈38320 J/mol\ln(100.0/25.0) = \frac{\Delta H_{\text{vap}}}{8.314}\left(\frac{1}{313.15} - \frac{1}{353.15}\right) \implies 1.3863 = \frac{\Delta H_{\text{vap}}}{8.314}(0.0003617) \implies \Delta H_{\text{vap}} \approx 38320\text{ J/mol}. Then M=ΔHvapΔhvap=38320 J/mol500.0 J/g≈76.6 g/molM = \frac{\Delta H_{\text{vap}}}{\Delta h_{\text{vap}}} = \frac{38320\text{ J/mol}}{500.0\text{ J/g}} \approx 76.6\text{ g/mol}.

Loading workspace…