Resources

A concentration cell consists of two identical silver electrodes, each immersed in an Ag+(aq)\text{Ag}^+(aq) solution at 298 K298\text{ K}: Ag+(aq)+e−→Ag(s)E∘=+0.800 V\text{Ag}^+(aq) + e^- \rightarrow \text{Ag}(s) \quad E^\circ = +0.800\text{ V} The cathode compartment has a fixed concentration of [Ag+]cathode=1.00 M[\text{Ag}^+]_{\text{cathode}} = 1.00\text{ M}. The anode compartment is prepared by severe asymptotic serial dilution such that the added salt yields a formal silver concentration approaching zero: [Ag+]added=1.00×10−10 M[\text{Ag}^+]_{\text{added}} = 1.00 \times 10^{-10}\text{ M}. (a) Express EcellE_{\text{cell}} as a function of the anode silver ion concentration using the Nernst equation (n=1n = 1). (b) Calculate EcellE_{\text{cell}} when [Ag+]anode=1.00×10−10 M[\text{Ag}^+]_{\text{anode}} = 1.00 \times 10^{-10}\text{ M}. (c) What physical barrier prevents EcellE_{\text{cell}} from increasing asymptotically toward infinity as [Ag+]added→0 M[\text{Ag}^+]_{\text{added}} \rightarrow 0\text{ M} in pure water?

Answer and steps

Final answer

(a) Ecell=−0.0592 Vlog⁡[Ag+]anodeE_{\text{cell}} = -0.0592\text{ V} \log[\text{Ag}^+]_{\text{anode}}; (b) Ecell=+0.592 VE_{\text{cell}} = +0.592\text{ V}; (c) As [Ag+]added→0[\text{Ag}^+]_{\text{added}} \rightarrow 0, the trace dissolution/corrosion of the metallic silver electrode and the finite autodissociation/redox potential of water establish a non-zero thermodynamic lower bound on silver ion concentration, preventing [extAg+]anode[ ext{Ag}^+]_{\text{anode}} from reaching absolute zero and capping the maximum cell voltage.

Steps

01

Formulate the Concentration Cell Reaction

A concentration cell generates an electric potential due to the concentration gradient of the same chemical species across two half-cells.

The two half-reactions are:

  • Cathode (reduction): AgX+(aq,cathode)+eX−→Ag(s)\ce{Ag+(aq, cathode) + e- -> Ag(s)}
  • Anode (oxidation): Ag(s)→AgX+(aq,anode)+eX−\ce{Ag(s) -> Ag+(aq, anode) + e-}

Adding both half-reactions yields the overall cell reaction: AgX+(aq,cathode)→AgX+(aq,anode)\ce{Ag+(aq, cathode) -> Ag+(aq, anode)}

Because both compartments use identical Ag/AgX+\ce{Ag/Ag+} electrodes, the standard reduction potentials cancel out: Ecell∘=Ecathode∘−Eanode∘=0.800 V−0.800 V=0 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = 0.800\text{ V} - 0.800\text{ V} = 0\text{ V}

The reaction quotient QQ for this process is: Q=[AgX+]anode[AgX+]cathodeQ = \frac{[\ce{Ag+}]_{\text{anode}}}{[\ce{Ag+}]_{\text{cathode}}}

Given that [AgX+]cathode=1.00 M[\ce{Ag+}]_{\text{cathode}} = 1.00\text{ M}, this simplifies to: Q=[AgX+]anodeQ = [\ce{Ag+}]_{\text{anode}}


02

Derive the Expression for EcellE_{\text{cell}} (Part a)

Apply the Nernst equation at T=298 KT = 298\text{ K} with n=1n = 1: Ecell=Ecell∘−0.0592 Vnlog⁡QE_{\text{cell}} = E^\circ_{\text{cell}} - \frac{0.0592\text{ V}}{n} \log Q

Substituting Ecell∘=0 VE^\circ_{\text{cell}} = 0\text{ V}, n=1n = 1, and Q=[AgX+]anodeQ = [\ce{Ag+}]_{\text{anode}}: Ecell=−0.0592 Vlog⁡[AgX+]anodeE_{\text{cell}} = -0.0592\text{ V} \log[\ce{Ag+}]_{\text{anode}}


03

Calculate the Potential at [AgX+]anode=1.00×10−10 M[\ce{Ag+}]_{\text{anode}} = 1.00 \times 10^{-10}\text{ M} (Part b)

Substitute [AgX+]anode=1.00×10−10 M[\ce{Ag+}]_{\text{anode}} = 1.00 \times 10^{-10}\text{ M} into the derived Nernst equation: Ecell=−0.0592 Vlog⁡(1.00×10−10)E_{\text{cell}} = -0.0592\text{ V} \log(1.00 \times 10^{-10})

Since log⁡(1.00×10−10)=−10\log(1.00 \times 10^{-10}) = -10: Ecell=−0.0592 V×(−10)=+0.592 VE_{\text{cell}} = -0.0592\text{ V} \times (-10) = +0.592\text{ V}


04

Identify the Physical Limitation on Maximum Potential (Part c)

Mathematically, as [AgX+]anode→0 M[\ce{Ag+}]_{\text{anode}} \to 0\text{ M}, log⁡[AgX+]anode→−∞\log[\ce{Ag+}]_{\text{anode}} \to -\infty, suggesting that Ecell→+∞E_{\text{cell}} \to +\infty.

However, this infinite voltage cannot occur physically due to chemical constraints:

  1. Metallic Silver Dissolution: Solid metallic silver (Ag(s)\ce{Ag(s)}) in contact with pure water will undergo spontaneous trace dissolution and oxidation (corrosion) until a dynamic balance is reached.
  2. Redox Window of Water: Dissolved oxygen, residual hydronium ions, and the autodissociation of water provide thermodynamic pathways that oxidize trace amounts of Ag(s)\ce{Ag(s)} into AgX+(aq)\ce{Ag+(aq)}.

Consequently, these processes enforce an intrinsic, non-zero thermodynamic floor on [AgX+]anode[\ce{Ag+}]_{\text{anode}}, preventing the concentration from ever reaching absolute zero and thus capping the maximum cell voltage at a finite value.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student inverts the ratio of concentrations in the reaction quotient Q by placing cathode over anode.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Ecell∘=0 V  ⟹  Q=[AgX+]cathode[AgX+]anode  ⟹  Ecell=0.0592log⁡([AgX+]anode) VE^\circ_{\text{cell}} = 0\text{ V} \implies Q = \frac{[\ce{Ag+}]_{\text{cathode}}}{[\ce{Ag+}]_{\text{anode}}} \implies E_{\text{cell}} = 0.0592 \log([\ce{Ag+}]_{\text{anode}})\text{ V}

    Correct

    Q=[AgX+]anode[AgX+]cathode=[AgX+]anode  ⟹  Ecell=−0.0592 Vlog⁡([AgX+]anode)Q = \frac{[\ce{Ag+}]_{\text{anode}}}{[\ce{Ag+}]_{\text{cathode}}} = [\ce{Ag+}]_{\text{anode}} \implies E_{\text{cell}} = -0.0592\text{ V} \log([\ce{Ag+}]_{\text{anode}})

    In a galvanic cell, oxidation takes place at the anode (producing AgX+(aq,anode)\ce{Ag+(aq, anode)}) and reduction takes place at the cathode (consuming AgX+(aq,cathode)\ce{Ag+(aq, cathode)}). Therefore, the overall reaction is AgX+(aq,cathode)→AgX+(aq,anode)\ce{Ag+(aq, cathode) -> Ag+(aq, anode)}, making Q=[AgX+]anode[AgX+]cathodeQ = \frac{[\ce{Ag+}]_{\text{anode}}}{[\ce{Ag+}]_{\text{cathode}}}. Inverting this ratio changed the sign of the Nernst log term.

  2. Step 2

    Ecell=0.0592×log⁡(1.00×10−10)  ⟹  Ecell=0.0592×(−10)=−0.592 VE_{\text{cell}} = 0.0592 \times \log(1.00 \times 10^{-10}) \implies E_{\text{cell}} = 0.0592 \times (-10) = -0.592\text{ V}

    Correct

    Ecell=−0.0592 V×log⁡(1.00×10−10)=+0.592 VE_{\text{cell}} = -0.0592\text{ V} \times \log(1.00 \times 10^{-10}) = +0.592\text{ V}

    Your arithmetic evaluation was carried out correctly following your formula from part (a), but the sign is negative due to the inverted reaction quotient. A spontaneous galvanic cell must yield Ecell>0E_{\text{cell}} > 0.

  3. Step 3

    The electrode dissolves slightly to set a minimum silver ion concentration in the anode.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recognized that the standard potential Ecell∘E^\circ_{\text{cell}} for identical concentration half-cells is 0 V0\text{ V}.

You accurately identified that trace dissolution of the solid silver electrode creates a physical lower bound on the silver ion concentration in part (c).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted reaction quotient in Nernst equation

You accidentally placed cathode over anode in the reaction quotient QQ, leading to a flipped sign.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing products and reactants when formulating QQ for a concentration cell. Remember that the anode is the site of oxidation (producing ions, so it goes in the numerator/products), while the cathode is the site of reduction (consuming ions, so it goes in the denominator/reactants).

REASONING PATH
Your ACEpath teacher’s suggested approach
Formulate Net Cell Reaction
  • Anode oxidizes metal to aqueous ions; cathode reduces aqueous ions to metal: MXn+(cathode)→MXn+(anode)\ce{M^{n+}(cathode) -> M^{n+}(anode)}.

  • Write the net ionic equation explicitly to verify which concentration is the product and which is the reactant.

Sanity Check Galvanic Cell Potential
  • A spontaneous concentration cell always drives ions from high concentration to low concentration, requiring Ecell>0E_{\text{cell}} > 0.

  • If your calculated EcellE_{\text{cell}} is negative when [ion]anode<[ion]cathode[\ce{ion}]_{\text{anode}} < [\ce{ion}]_{\text{cathode}}, recheck the orientation of QQ in the Nernst equation.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the overall cell reaction: AgX+(aq,cathode)→AgX+(aq,anode)\ce{Ag+(aq, cathode) -> Ag+(aq, anode)}.

  2. Express the reaction quotient: Q=[AgX+]anode[AgX+]cathode=[AgX+]anode1.00=[AgX+]anodeQ = \frac{[\ce{Ag+}]_{\text{anode}}}{[\ce{Ag+}]_{\text{cathode}}} = \frac{[\ce{Ag+}]_{\text{anode}}}{1.00} = [\ce{Ag+}]_{\text{anode}}.

  3. Apply the Nernst equation: Ecell=E∘−0.05921log⁡Q=0−0.0592log⁡[AgX+]anode=−0.0592log⁡[AgX+]anodeE_{\text{cell}} = E^\circ - \frac{0.0592}{1}\log Q = 0 - 0.0592\log[\ce{Ag+}]_{\text{anode}} = -0.0592\log[\ce{Ag+}]_{\text{anode}}.

  4. Substitute [AgX+]anode=1.00×10−10 M[\ce{Ag+}]_{\text{anode}} = 1.00 \times 10^{-10}\text{ M}: Ecell=−0.0592×(−10)=+0.592 VE_{\text{cell}} = -0.0592 \times (-10) = +0.592\text{ V}.

Final answer

(a) Ecell=−0.0592 Vlog⁡[AgX+]anodeE_{\text{cell}} = -0.0592\text{ V} \log[\ce{Ag+}]_{\text{anode}}; (b) Ecell=+0.592 VE_{\text{cell}} = +0.592\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice deriving QQ directly from the two balanced half-reactions rather than memorizing formulas.

  • Always perform a quick sign check: when diluting the anode compartment relative to the cathode, EcellE_{\text{cell}} must be positive.

OverviewACEpath Teacher's Diagnosis

02 The student uses the standard reduction potential of the silver electrode (+0.800 V) instead of zero as E°cell for the identical-electrode concentration cell.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Ecell∘=0.800 V  ⟹  Ecell=Ecell∘−0.0592×log⁡([Ag+]anode1.00)  ⟹  Ecell=0.800−0.0592×log⁡([Ag+]anode) VE^\circ_{\text{cell}} = 0.800\text{ V} \implies E_{\text{cell}} = E^\circ_{\text{cell}} - 0.0592 \times \log\left(\frac{[\text{Ag}^+]_{\text{anode}}}{1.00}\right) \implies E_{\text{cell}} = 0.800 - 0.0592 \times \log([\text{Ag}^+]_{\text{anode}})\text{ V}

    Correct

    Ecell∘=Ecathode∘−Eanode∘=0.800 V−0.800 V=0 V  ⟹  Ecell=−0.0592 Vlog⁡[Ag+]anodeE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = 0.800\text{ V} - 0.800\text{ V} = 0\text{ V} \implies E_{\text{cell}} = -0.0592\text{ V} \log[\text{Ag}^+]_{\text{anode}}

    You correctly set up the reaction quotient Q=[Ag+]anode[Ag+]cathode=[Ag+]anodeQ = \frac{[\text{Ag}^+]_{\text{anode}}}{[\text{Ag}^+]_{\text{cathode}}} = [\text{Ag}^+]_{\text{anode}}, but in a concentration cell both half-cells consist of the same Ag/Ag+\text{Ag}/\text{Ag}^+ couple. Therefore, the standard cell potential is Ecell∘=Ecathode∘−Eanode∘=0.800 V−0.800 V=0 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = 0.800\text{ V} - 0.800\text{ V} = 0\text{ V}, not 0.800 V0.800\text{ V}.

  2. Step 2

    Ecell=0.800−0.0592×log⁡(1.00×10−10)  ⟹  Ecell=0.800−0.0592×(−10)  ⟹  Ecell=0.800+0.592=1.392 VE_{\text{cell}} = 0.800 - 0.0592 \times \log(1.00 \times 10^{-10}) \implies E_{\text{cell}} = 0.800 - 0.0592 \times (-10) \implies E_{\text{cell}} = 0.800 + 0.592 = 1.392\text{ V}

    Correct

    Ecell=0−0.0592 V×(−10)=+0.592 VE_{\text{cell}} = 0 - 0.0592\text{ V} \times (-10) = +0.592\text{ V}

    Your logarithmic evaluation and arithmetic were executed correctly, but the result is offset by +0.800 V+0.800\text{ V} due to using the incorrect standard cell potential from Step 1.

  3. Step 3

    Dissolution of the silver electrode prevents [Ag+] from reaching zero.\text{Dissolution of the silver electrode prevents }[\text{Ag}^+]\text{ from reaching zero.}

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly expressed the reaction quotient as Q=[Ag+]anode/[Ag+]cathode=[Ag+]anodeQ = [\text{Ag}^+]_{\text{anode}} / [\text{Ag}^+]_{\text{cathode}} = [\text{Ag}^+]_{\text{anode}}.

You evaluated log⁡(1.00×10−10)=−10\log(1.00 \times 10^{-10}) = -10 and handled the negative signs accurately.

You identified the physical limitation in part (c) regarding electrode dissolution.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Standard Potential of Concentration Cells

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You used the standard reduction potential of an individual silver electrode (E∘=+0.800 VE^\circ = +0.800\text{ V}) as the overall standard cell potential Ecell∘E^\circ_{\text{cell}}, forgetting that identical electrodes cancel out so that Ecell∘=Ecathode∘−Eanode∘=0 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = 0\text{ V} for any concentration cell.

REASONING PATH
Your ACEpath teacher’s suggested approach
Standard Cell Potential in Concentration Cells
  • For any concentration cell where cathode and anode share the same half-reaction, Ecell∘=Ered∘(cathode)−Ered∘(anode)=0 VE^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) - E^\circ_{\text{red}}(\text{anode}) = 0\text{ V}.

  • Always set Ecell∘=0 VE^\circ_{\text{cell}} = 0\text{ V} before writing out the Nernst equation for concentration cells.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set Ecell∘=0 VE^\circ_{\text{cell}} = 0\text{ V} because both half-cells use identical silver electrodes.

  2. Write the Nernst equation: Ecell=0−0.0592 Vlog⁡[Ag+]anode=−0.0592 Vlog⁡[Ag+]anodeE_{\text{cell}} = 0 - 0.0592\text{ V} \log[\text{Ag}^+]_{\text{anode}} = -0.0592\text{ V} \log[\text{Ag}^+]_{\text{anode}}.

  3. Substitute [Ag+]anode=1.00×10−10 M[\text{Ag}^+]_{\text{anode}} = 1.00 \times 10^{-10}\text{ M}: Ecell=−0.0592 V×(−10)=+0.592 VE_{\text{cell}} = -0.0592\text{ V} \times (-10) = +0.592\text{ V}.

Final answer

(a) Ecell=−0.0592 Vlog⁡[Ag+]anodeE_{\text{cell}} = -0.0592\text{ V} \log[\text{Ag}^+]_{\text{anode}}; (b) Ecell=+0.592 VE_{\text{cell}} = +0.592\text{ V}; (c) Trace dissolution of the silver electrode prevents [Ag+][\text{Ag}^+] from reaching zero.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review why Ecell∘=0 VE^\circ_{\text{cell}} = 0\text{ V} for all concentration cells.

  • Practice calculating voltages for concentration cells with different metal ion couples.

  • Remember that the driving force of a concentration cell comes entirely from the entropic gradient (−RT/nFln⁡Q-RT/nF \ln Q), not standard reduction potential differences.

OverviewACEpath Teacher's Diagnosis

03 The student attributes the limit on cell potential to water autoionization producing H+ and OH- ions rather than electrode dissolution maintaining a minimum [Ag+].

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Ecell∘=0 V  ⟹  Ecell=−0.0592×log⁡([Ag+]anode) VE^\circ_{\text{cell}} = 0\text{ V} \implies E_{\text{cell}} = -0.0592 \times \log([\text{Ag}^+]_{\text{anode}})\text{ V}

  2. Step 2

    Ecell=−0.0592×log⁡(1.00×10−10)  ⟹  Ecell=+0.592 VE_{\text{cell}} = -0.0592 \times \log(1.00 \times 10^{-10}) \implies E_{\text{cell}} = +0.592\text{ V}

  3. Step 3

    Water autodissociates into H+\text{H}^+ and OH−\text{OH}^- with Kw=1.0×10−14K_w = 1.0 \times 10^{-14}. The 1.0×10−7 M H+1.0 \times 10^{-7}\text{ M }\text{H}^+ ions compete at the electrode and prevent EcellE_{\text{cell}} from increasing further.

    Correct

    Spontaneous trace dissolution and corrosion of the solid silver electrode in aqueous solution establish a non-zero thermodynamic floor on [Ag+]anode[\text{Ag}^+]_{\text{anode}}, preventing it from reaching absolute zero and capping EcellE_{\text{cell}}.

    You attributed the potential limit to H+\text{H}^+ competition, but the actual physical constraint is that solid silver metal immersed in water undergoes spontaneous trace dissolution (oxidation), ensuring that the true [Ag+][\text{Ag}^+] cannot drop to absolute zero.

WHAT YOU DID WELL
Compliments from Your Teacher

You recognized that identical half-cells produce a standard cell potential of zero.

You formulated the correct logarithmic dependence of cell potential on the dilute ion concentration.

You calculated the cell voltage accurately for the 1.00×10−10 M1.00 \times 10^{-10}\text{ M} solution.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Misidentifying the physical limitation on concentration cell potential

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You assumed that the solvent's autodissociated ions act as a competing redox couple rather than recognizing that an insoluble metal electrode itself undergoes trace dissolution/corrosion, which thermodynamically enforces a non-zero concentration floor for its own cation.

REASONING PATH
Your ACEpath teacher’s suggested approach
Evaluate the Electrode-Solution Interface
  • A solid metal immersed in pure water is never at absolute zero dissolved metal ion concentration; trace oxidation occurs until dynamic equilibrium is reached.

  • Consider whether the electrode material itself can dissolve into solution to maintain a baseline ion concentration before looking for external competing species.

Analyze the Logarithmic Singularity in the Nernst Equation
  • As [Mn+]→0[\text{M}^{n+}] \to 0, Ecell→∞E_{\text{cell}} \to \infty, which violates conservation of energy and real thermodynamic equilibria.

  • Identify the chemical process that prevents [Mn+][\text{M}^{n+}] from mathematically reaching zero in an open or aqueous system.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. The Nernst expression predicts Ecell→+∞E_{\text{cell}} \to +\infty only if [Ag+]anode→0 M[\text{Ag}^+]_{\text{anode}} \to 0\text{ M}.

  2. When solid metallic silver (Ag(s)\text{Ag}(s)) is placed in contact with water containing no initial silver ions, a chemical driving force causes spontaneous trace dissolution/corrosion: Ag(s)⇌Ag+(aq)+e−\text{Ag}(s) \rightleftharpoons \text{Ag}^+(aq) + e^-, driven by trace oxidants like dissolved oxygen or the water redox window.

  3. This spontaneous release establishes a non-zero thermodynamic lower bound on [Ag+][\text{Ag}^+], preventing the argument of the logarithm from reaching zero.

Final answer

Trace dissolution of the solid silver electrode establishes an intrinsic non-zero lower bound for [Ag+]anode[\text{Ag}^+]_{\text{anode}}, preventing the concentration from reaching zero and capping EcellE_{\text{cell}} at a finite value.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review how corrosion and metal-water phase equilibria establish minimum equilibrium ion activities.

  • Distinguish between parallel competing electrode reactions (overpotentials) and chemical equilibria that buffer ion concentrations at an electrode surface.

Lock it in

Similar question

01

A copper concentration cell consists of two Cu/CuX2+\ce{Cu/Cu^2+} half-cells at 298 K298\text{ K} (n=2n = 2). The cathode has [CuX2+]=2.0 M[\ce{Cu^2+}] = 2.0\text{ M} and the anode has [CuX2+]=2.0×10−4 M[\ce{Cu^2+}] = 2.0 \times 10^{-4}\text{ M}. Calculate EcellE_{\text{cell}}.

Answer

Ecell=+0.118 VE_{\text{cell}} = +0.118\text{ V}. Key steps: E∘=0 VE^\circ = 0\text{ V}, Q=[CuX2+]anode[CuX2+]cathode=2.0×10−42.0=1.0×10−4Q = \frac{[\ce{Cu^2+}]_{\text{anode}}}{[\ce{Cu^2+}]_{\text{cathode}}} = \frac{2.0 \times 10^{-4}}{2.0} = 1.0 \times 10^{-4}. Ecell=−0.05922log⁡(10−4)=−0.0296×(−4)=+0.118 VE_{\text{cell}} = -\frac{0.0592}{2}\log(10^{-4}) = -0.0296 \times (-4) = +0.118\text{ V}.

02

A concentration cell is constructed with two identical nickel electrodes: Ni(s) ∣ NiX2+(aq,?M) ∣∣ NiX2+(aq,0.50M) ∣ Ni(s)\ce{Ni(s) | Ni^2+(aq, ? M) || Ni^2+(aq, 0.50 M) | Ni(s)} at 298 K298\text{ K} (n=2n = 2). If the measured potential is Ecell=+0.0888 VE_{\text{cell}} = +0.0888\text{ V}, determine the concentration of NiX2+\ce{Ni^2+} in the anode compartment.

Answer

[NiX2+]anode=5.0×10−4 M[\ce{Ni^2+}]_{\text{anode}} = 5.0 \times 10^{-4}\text{ M}. Key steps: Ecell=−0.05922log⁡Q  ⟹  0.0888=−0.0296log⁡Q  ⟹  log⁡Q=−3  ⟹  Q=10−3E_{\text{cell}} = -\frac{0.0592}{2}\log Q \implies 0.0888 = -0.0296\log Q \implies \log Q = -3 \implies Q = 10^{-3}. Since Q=[NiX2+]anode0.50Q = \frac{[\ce{Ni^2+}]_{\text{anode}}}{0.50}, [NiX2+]anode=0.50×10−3=5.0×10−4 M[\ce{Ni^2+}]_{\text{anode}} = 0.50 \times 10^{-3} = 5.0 \times 10^{-4}\text{ M}.

03

A silver concentration cell has [AgX+]cathode=0.100 M[\ce{Ag+}]_{\text{cathode}} = 0.100\text{ M}. In the anode half-cell, solid AgCl\ce{AgCl} is equilibrated in pure water with excess ClX−\ce{Cl-} such that [ClX−]=0.0200 M[\ce{Cl-}] = 0.0200\text{ M} (Ksp(AgCl)=1.8×10−10K_{\text{sp}}(\ce{AgCl}) = 1.8 \times 10^{-10} at 298 K298\text{ K}). Calculate EcellE_{\text{cell}} at 298 K298\text{ K}.

Answer

Ecell=+0.417 VE_{\text{cell}} = +0.417\text{ V}. Key steps: Find [AgX+]anode=Ksp[ClX−]=1.8×10−100.0200=9.0×10−9 M[\ce{Ag+}]_{\text{anode}} = \frac{K_{\text{sp}}}{[\ce{Cl-}]} = \frac{1.8 \times 10^{-10}}{0.0200} = 9.0 \times 10^{-9}\text{ M}. Then Q=[AgX+]anode[AgX+]cathode=9.0×10−90.100=9.0×10−8Q = \frac{[\ce{Ag+}]_{\text{anode}}}{[\ce{Ag+}]_{\text{cathode}}} = \frac{9.0 \times 10^{-9}}{0.100} = 9.0 \times 10^{-8}. Finally, Ecell=−0.0592log⁡(9.0×10−8)=−0.0592×(−7.046)=+0.417 VE_{\text{cell}} = -0.0592 \log(9.0 \times 10^{-8}) = -0.0592 \times (-7.046) = +0.417\text{ V}.

Loading workspace…