Resources

A cylinder of pure copper has a measured mass of m=(48.36±0.04) gm = (48.36 \pm 0.04)\text{ g}, a length of l=(3.50±0.02) cml = (3.50 \pm 0.02)\text{ cm}, and a diameter of d=(1.40±0.01) cmd = (1.40 \pm 0.01)\text{ cm}. Rather than determining the absolute uncertainty in density, determine the total percent relative uncertainty (%ερ\%\varepsilon_\rho) associated with the calculated density ρ=4mπd2l\rho = \frac{4m}{\pi d^2 l}.

Answer and steps

Final answer

%ερ=2.1%\%\varepsilon_\rho = 2.1\%

Steps

01

Recall the propagation rule for relative uncertainties

To find the total percent relative uncertainty (%ερ\%\varepsilon_\rho) in the density, follow the rules of uncertainty propagation for quantities combined by multiplication, division, and powers.

The density formula is: ρ=4mπd2l\rho = \frac{4m}{\pi d^2 l}

Pure numerical constants (such as 44 and π\pi) have zero uncertainty. For products, quotients, and powers:

  • When quantities are multiplied or divided, their relative uncertainties add directly.
  • When a quantity is raised to an exponent nn, its relative uncertainty is multiplied by nn.

Therefore, the total percent relative uncertainty is: %ερ=%εm+2⋅%εd+%εl\%\varepsilon_\rho = \%\varepsilon_m + 2 \cdot \%\varepsilon_d + \%\varepsilon_l

Common Pitfall: Forgetting to multiply the relative uncertainty of the diameter by 22. Because diameter is squared in the volume formula (d2d^2), its fractional error contributes twice as much to the uncertainty in density.


02

Calculate the percent uncertainty for each measured value

The percent uncertainty of a measurement x±Δxx \pm \Delta x is given by: %εx=Δxx×100%\%\varepsilon_x = \frac{\Delta x}{x} \times 100\%

  • Mass (mm): %εm=0.04 g48.36 g×100%≈0.0827%\%\varepsilon_m = \frac{0.04\text{ g}}{48.36\text{ g}} \times 100\% \approx 0.0827\%
  • Diameter (dd): %εd=0.01 cm1.40 cm×100%≈0.7143%\%\varepsilon_d = \frac{0.01\text{ cm}}{1.40\text{ cm}} \times 100\% \approx 0.7143\%
  • Length (ll): %εl=0.02 cm3.50 cm×100%≈0.5714%\%\varepsilon_l = \frac{0.02\text{ cm}}{3.50\text{ cm}} \times 100\% \approx 0.5714\%

03

Sum the weighted percent uncertainties

Substitute the individual percent uncertainties into the propagation formula: %ερ=0.0827%+2(0.7143%)+0.5714%\%\varepsilon_\rho = 0.0827\% + 2(0.7143\%) + 0.5714\% %ερ=0.0827%+1.4286%+0.5714%=2.0827%\%\varepsilon_\rho = 0.0827\% + 1.4286\% + 0.5714\% = 2.0827\%

Rounding to two significant figures (matching the single significant digit in the measurement uncertainties): %ερ=2.1%\%\varepsilon_\rho = 2.1\%

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to multiply the relative uncertainty of the diameter by its power of 2 when propagating uncertainty.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    %εm=(0.0448.36)×100%=0.083%\%\varepsilon_m = \left(\frac{0.04}{48.36}\right) \times 100\% = 0.083\% ⟹\Longrightarrow %εd=(0.011.40)×100%=0.714%\%\varepsilon_d = \left(\frac{0.01}{1.40}\right) \times 100\% = 0.714\% ⟹\Longrightarrow %εl=(0.023.50)×100%=0.571%\%\varepsilon_l = \left(\frac{0.02}{3.50}\right) \times 100\% = 0.571\%

  2. Step 2

    %ερ=%εm+%εd+%εl\%\varepsilon_\rho = \%\varepsilon_m + \%\varepsilon_d + \%\varepsilon_l

    Correct

    %ερ=%εm+2⋅%εd+%εl\%\varepsilon_\rho = \%\varepsilon_m + 2\cdot\%\varepsilon_d + \%\varepsilon_l

    In the formula ρ=4mπd2l\rho = \frac{4m}{\pi d^2 l}, the variable dd is raised to the second power. By the rules of uncertainty propagation for powers, its relative uncertainty must be weighted by a factor of 22.

  3. Step 3

    %ερ=0.083%+0.714%+0.571%=1.368%≈1.4%\%\varepsilon_\rho = 0.083\% + 0.714\% + 0.571\% = 1.368\% \approx 1.4\%

    Correct

    %ερ=0.083%+2(0.714%)+0.571%=2.082%≈2.1%\%\varepsilon_\rho = 0.083\% + 2(0.714\%) + 0.571\% = 2.082\% \approx 2.1\%

    Because the diameter term omitted the factor of 22, the resulting sum and rounded final answer are underestimated.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified the formula for percent relative uncertainty: %ε=Δxx×100%\%\varepsilon = \frac{\Delta x}{x} \times 100\%.

You accurately computed and rounded the individual percent uncertainties for mass, diameter, and length.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Uncertainty propagation power rule omitted

You treated the diameter as a linear term rather than accounting for its exponent of 22 in the formula ρ=4mπd2l\rho = \frac{4m}{\pi d^2 l}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

When combining independent variables via multiplication, division, or powers, each variable's relative uncertainty is multiplied by the absolute value of its exponent: for y=kapbqcry = k \frac{a^p b^q}{c^r}, the relative uncertainty propagates as %εy=p(%εa)+q(%εb)+r(%εc)\%\varepsilon_y = p(\%\varepsilon_a) + q(\%\varepsilon_b) + r(\%\varepsilon_c).

REASONING PATH
Your ACEpath teacher’s suggested approach
Power Rule in Uncertainty Propagation
  • For any quantity xnx^n, the relative uncertainty contributes ∣n∣×%εx|n| \times \%\varepsilon_x.

  • Inspect each variable in the governing equation and write its exponent as an explicit coefficient in front of its relative uncertainty before substituting numbers.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the power rule: %ερ=%εm+2⋅%εd+%εl\%\varepsilon_\rho = \%\varepsilon_m + 2\cdot\%\varepsilon_d + \%\varepsilon_l

  2. Substitute the individual percentage values: %ερ=0.0827%+2(0.7143%)+0.5714%=2.0827%\%\varepsilon_\rho = 0.0827\% + 2(0.7143\%) + 0.5714\% = 2.0827\%

  3. Round to two significant figures matching the uncertainty precision: %ερ≈2.1%\%\varepsilon_\rho \approx 2.1\%

Final answer

%ερ=2.1%\%\varepsilon_\rho = 2.1\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Before adding relative uncertainties, write down the formula with exponent multipliers: z=xaybwc  ⟹  %εz=a(%εx)+b(%εy)+c(%εw)z = \frac{x^a y^b}{w^c} \implies \%\varepsilon_z = a(\%\varepsilon_x) + b(\%\varepsilon_y) + c(\%\varepsilon_w).

  • Double-check geometric formulas (such as areas and volumes) where radius or diameter is squared or cubed, as these variables contribute disproportionately to the total error.

OverviewACEpath Teacher's Diagnosis

02 The student simply sums the absolute uncertainties rather than converting them to percent relative uncertainties.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    %ερ=Δm+2Δd+Δl\%\varepsilon_\rho = \Delta m + 2\Delta d + \Delta l

    Correct

    %ερ=%εm+2⋅%εd+%εl=(Δmm+2Δdd+Δll)×100%\%\varepsilon_\rho = \%\varepsilon_m + 2\cdot\%\varepsilon_d + \%\varepsilon_l = \left(\frac{\Delta m}{m} + 2\frac{\Delta d}{d} + \frac{\Delta l}{l}\right) \times 100\%

    For quantities combined through multiplication, division, and powers, relative uncertainties combine rather than absolute uncertainties. You wrote a sum of absolute uncertainties (Δm,Δd,ΔlΔm, Δd, Δl), which have incompatible units (grams and centimeters) and cannot be added together.

  2. Step 2

    %ερ=0.04+2(0.01)+0.02  ⟹  %ερ=0.04+0.02+0.02=0.08%\%\varepsilon_\rho = 0.04 + 2(0.01) + 0.02 \implies \%\varepsilon_\rho = 0.04 + 0.02 + 0.02 = 0.08\%

    Correct

    %ερ=(0.0448.36+2⋅0.011.40+0.023.50)×100%≈0.0827%+1.4286%+0.5714%=2.1%\%\varepsilon_\rho = \left(\frac{0.04}{48.36} + 2\cdot\frac{0.01}{1.40} + \frac{0.02}{3.50}\right) \times 100\% \approx 0.0827\% + 1.4286\% + 0.5714\% = 2.1\%

    You substituted the absolute uncertainties into your formula from Step 1. While your arithmetic was correct for the expression you wrote, the numerical result is incorrect due to the initial formula error.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that the diameter term is squared in the volume formula, which requires multiplying its uncertainty contribution by 22.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Summed absolute uncertainties instead of relative uncertainties

You treated the absolute uncertainties Δx\Delta x as if they were already relative or percent uncertainties.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the propagation rules for addition/subtraction with those for multiplication/division/powers. Absolute uncertainties only add when quantities are added or subtracted. When quantities are multiplied, divided, or raised to powers, you must convert each absolute uncertainty Δx\Delta x to a fractional relative uncertainty Δxx\frac{\Delta x}{x} (or percent uncertainty) before combining them.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check the Operation Type
  • Addition/subtraction propagates absolute uncertainties (y=a+b  ⟹  Δy=Δa+Δby = a + b \implies \Delta y = \Delta a + \Delta b), whereas multiplication/division/powers propagate relative uncertainties (y=abn  ⟹  Δyy=Δaa+nΔbby = \frac{a}{b^n} \implies \frac{\Delta y}{y} = \frac{\Delta a}{a} + n\frac{\Delta b}{b}).

  • Before writing an uncertainty expression, check the mathematical operations in the target formula.

Dimensional Unit Sanity Check
  • Quantities with different physical dimensions (such as grams and centimeters) can never be added together.

  • Verify that terms being added have identical units. Since relative uncertainties are dimensionless ratios, they can always be safely added.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert each measurement into its percent relative uncertainty using %εx=Δxx×100%\%\varepsilon_x = \frac{\Delta x}{x} \times 100\%.

  2. Calculate for mass: %εm=0.04 g48.36 g×100%≈0.0827%\%\varepsilon_m = \frac{0.04\text{ g}}{48.36\text{ g}} \times 100\% \approx 0.0827\%.

  3. Calculate for diameter: %εd=0.01 cm1.40 cm×100%≈0.7143%\%\varepsilon_d = \frac{0.01\text{ cm}}{1.40\text{ cm}} \times 100\% \approx 0.7143\%.

  4. Calculate for length: %εl=0.02 cm3.50 cm×100%≈0.5714%\%\varepsilon_l = \frac{0.02\text{ cm}}{3.50\text{ cm}} \times 100\% \approx 0.5714\%.

  5. Sum the weighted percent uncertainties: %ερ=0.0827%+2(0.7143%)+0.5714%=2.0827%\%\varepsilon_\rho = 0.0827\% + 2(0.7143\%) + 0.5714\% = 2.0827\%.

Final answer

%ερ=2.1%\%\varepsilon_\rho = 2.1\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice identifying whether a formula uses addition/subtraction (add absolute uncertainties) or multiplication/division (add relative uncertainties).

  • Always calculate fractional uncertainties Δxx\frac{\Delta x}{x} first whenever evaluating products, quotients, or powers.

OverviewACEpath Teacher's Diagnosis

03 The student squares the relative uncertainty of the diameter instead of multiplying it by 2.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    %εm=0.0448.36×100%=0.083%\%\varepsilon_m = \frac{0.04}{48.36} \times 100\% = 0.083\%, %εd=0.011.40×100%=0.714%\%\varepsilon_d = \frac{0.01}{1.40} \times 100\% = 0.714\%, %εl=0.023.50×100%=0.571%\%\varepsilon_l = \frac{0.02}{3.50} \times 100\% = 0.571\%

  2. Step 2

    %ερ=%εm+(%εd)2+%εl\%\varepsilon_\rho = \%\varepsilon_m + (\%\varepsilon_d)^2 + \%\varepsilon_l

    Correct

    %ερ=%εm+2⋅%εd+%εl\%\varepsilon_\rho = \%\varepsilon_m + 2\cdot\%\varepsilon_d + \%\varepsilon_l

    When a quantity is raised to a power nn, its fractional/relative uncertainty is multiplied by nn, not raised to the power nn. For d2d^2, the contribution is 2⋅%εd2\cdot\%\varepsilon_d.

  3. Step 3

    %ερ=0.083%+(0.714%)2+0.571%=0.083%+0.005%+0.571%=0.659%≈0.66%\%\varepsilon_\rho = 0.083\% + (0.714\%)^2 + 0.571\% = 0.083\% + 0.005\% + 0.571\% = 0.659\% \approx 0.66\%

    Correct

    %ερ=0.083%+2(0.714%)+0.571%=2.082%≈2.1%\%\varepsilon_\rho = 0.083\% + 2(0.714\%) + 0.571\% = 2.082\% \approx 2.1\%

    Carrying the squared uncertainty term forward resulted in an underestimated final percent relative uncertainty.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the percent relative uncertainty for each measured variable.

You recognized that constants like 44 and π\pi contribute zero uncertainty to the density calculation.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Power rule misconception in relative uncertainty propagation

You squared the percent uncertainty (%εd)2(\%\varepsilon_d)^2 instead of multiplying it by the exponent: 2⋅%εd2\cdot\%\varepsilon_d.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the operation performed on the physical variable (d2d^2) with the propagation rule for relative uncertainties. In relative uncertainty propagation, an exponent nn acts as a linear multiplier (n⋅%εn \cdot \%\varepsilon), because fractional errors combine additively for each factor: d⋅d  ⟹  %εd+%εd=2⋅%εdd \cdot d \implies \%\varepsilon_d + \%\varepsilon_d = 2\cdot\%\varepsilon_d.

REASONING PATH
Your ACEpath teacher’s suggested approach
Power Rule for Relative Uncertainty
  • For a quantity y=xny = x^n, the relative uncertainty is %εy=∣n∣⋅%εx\%\varepsilon_y = |n| \cdot \%\varepsilon_x.

  • Always bring the exponent down as a multiplier in front of the relative uncertainty rather than raising the uncertainty itself to that power.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Substitute the individual percent uncertainties: %ερ=0.0827%+2(0.7143%)+0.5714%\%\varepsilon_\rho = 0.0827\% + 2(0.7143\%) + 0.5714\%.

  2. Multiply the diameter uncertainty by 22: 2×0.7143%=1.4286%2 \times 0.7143\% = 1.4286\%.

  3. Sum all contributions: %ερ=0.0827%+1.4286%+0.5714%=2.0827%\%\varepsilon_\rho = 0.0827\% + 1.4286\% + 0.5714\% = 2.0827\%.

  4. Round to two significant figures matching the measurement uncertainties: 2.1%2.1\%.

Final answer

%ερ=2.1%\%\varepsilon_\rho = 2.1\%

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the uncertainty propagation rules for powers: remember that xn=x⋅x⋯xx^n = x \cdot x \cdots x (nn times), so relative uncertainties add nn times.

  • Practice identifying the powers of all variables in a formula before writing the relative uncertainty expansion.

Lock it in

Similar question

01

A square metal plate has a measured side length of s=(12.0±0.3) cms = (12.0 \pm 0.3)\text{ cm}. Calculate the percent relative uncertainty in its measured area A=s2A = s^2.

Answer

%εA=5.0%\%\varepsilon_A = 5.0\%. Key steps: %εs=0.312.0×100%=2.5%\%\varepsilon_s = \frac{0.3}{12.0} \times 100\% = 2.5\%. For A=s2A = s^2, %εA=2×%εs=2×2.5%=5.0%\%\varepsilon_A = 2 \times \%\varepsilon_s = 2 \times 2.5\% = 5.0\%.

02

The period of a simple pendulum is given by T=2πLgT = 2\pi \sqrt{\frac{L}{g}}, or rearranged for gravity, g=4π2LT2g = 4\pi^2 \frac{L}{T^2}. If the percent uncertainty in length is %εL=1.2%\%\varepsilon_L = 1.2\% and in period is %εT=0.8%\%\varepsilon_T = 0.8\%, determine the total percent relative uncertainty in the calculated value of gg.

Answer

%εg=2.8%\%\varepsilon_g = 2.8\%. Key steps: Numerical constants (4π24\pi^2) carry zero uncertainty. Propagate according to powers: %εg=%εL+2(%εT)=1.2%+2(0.8%)=1.2%+1.6%=2.8%\%\varepsilon_g = \%\varepsilon_L + 2(\%\varepsilon_T) = 1.2\% + 2(0.8\%) = 1.2\% + 1.6\% = 2.8\%.

03

The pressure of an ideal gas is calculated using P=nRTVP = \frac{nRT}{V}, where n=(0.250±0.005) moln = (0.250 \pm 0.005)\text{ mol}, T=(300.0±1.5) KT = (300.0 \pm 1.5)\text{ K}, and the volume of a spherical container is V=43πr3V = \frac{4}{3}\pi r^3 with r=(10.0±0.2) cmr = (10.0 \pm 0.2)\text{ cm}. Assuming RR is an exact constant, find the total percent relative uncertainty in PP.

Answer

%εP=8.5%\%\varepsilon_P = 8.5\%. Key steps: %εn=0.0050.250×100%=2.0%\%\varepsilon_n = \frac{0.005}{0.250} \times 100\% = 2.0\%; %εT=1.5300.0×100%=0.5%\%\varepsilon_T = \frac{1.5}{300.0} \times 100\% = 0.5\%; %εr=0.210.0×100%=2.0%\%\varepsilon_r = \frac{0.2}{10.0} \times 100\% = 2.0\%. Since V∝r3V \propto r^3, %εV=3(%εr)=6.0%\%\varepsilon_V = 3(\%\varepsilon_r) = 6.0\%. Thus, %εP=%εn+%εT+3(%εr)=2.0%+0.5%+6.0%=8.5%\%\varepsilon_P = \%\varepsilon_n + \%\varepsilon_T + 3(\%\varepsilon_r) = 2.0\% + 0.5\% + 6.0\% = 8.5\%.

Loading workspace…