Resources
A nuclear reactor utilizes uranium-235 (, isotopic mass ) which undergoes induced fission via the representative reaction: . The rest masses are , , and , with conversion factor . If the reactor operates at an electrical power output of with a thermal-to-electric conversion efficiency of , calculate the total mass of consumed per day, in kilograms ().
Answer and steps
Final answer
Steps
Calculate the Total Thermal Energy Required per Day
A nuclear power plant converts thermal energy from nuclear fission into electrical energy with an efficiency .
- Calculate the thermal power output (): Given and :
- Calculate the total thermal energy produced in one day ():
Determine the Energy Released per Fission Event
-
Mass defect of the prompt fission reaction: For the induced fission reaction:
The net mass difference between reactants and products is:
-
Total usable thermal energy per fission:
- The immediate kinetic energy imparted to the fission fragments and prompt neutrons is:
- In an operating reactor, the radioactive daughter fragments ( and ) undergo successive and decays until reaching stable isotopes ( and ). Including prompt and delayed -rays, beta particles, and neutron capture heating (excluding escaping neutrinos), the total recoverable thermal energy per fission event averages:
Converting to joules:
Calculate the Mass of Consumed
- Find the total number of fissions required per day ():
- Calculate the mass of consumed: Since each fission event consumes one nucleus:
(Note: Standard nuclear reactor engineering establishes a consumption rate of approximately of per , which directly verifies: .)
Typical errors
01 The student multiplies by efficiency instead of dividing, confusing electrical power with thermal power and underestimating the consumed fuel.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You multiplied the electrical power by the efficiency instead of dividing. Efficiency is defined as , so the required thermal power must be larger than the electrical output: .
- Step 4Correct
Your conversion of daily power into total daily energy was mechanically correct, but the value is underestimated due to the thermal power error in Step 3.
- Step 5Correct
Your formula for calculating the total number of fission events was correct, but it carries forward the incorrect total energy.
- Step 6Correct
Your conversion from number of nuclei to mass in kilograms followed the correct method, but your final answer is too small due to the earlier efficiency calculation error.
WHAT YOU DID WELL
Compliments from Your TeacherYou set up the mass defect equation accurately by balancing the prompt fission reaction.
You used the correct unit conversion factor to calculate energy from atomic mass units.
You correctly used Avogadro's number and molar mass to convert the number of fission events into kilograms of fuel.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou wrote instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the total thermal input power with the useful electrical output power in the efficiency equation .
REASONING PATH
Your ACEpath teacher’s suggested approach- Sanity Check on Power Magnitudes
Real conversion processes have , meaning total input power must always be strictly greater than useful output power.
Whenever you compute thermal power from electrical power , verify that before continuing.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the true thermal power: .
Calculate total thermal energy required per day: .
Using total recoverable fission thermal energy (), find the number of fissions: .
Calculate consumed mass: .
02 The student subtracts all 3 product neutrons without accounting for the 1 incident reactant neutron, overestimating the mass defect and underestimating the consumed fuel.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
You subtracted all product neutrons from the mass of without adding the incident neutron on the reactant side. Because neutron initiates the reaction and neutrons are released, the net change is a loss of only neutron masses from the heavy nuclei.
- Step 2Correct
(, including total recoverable thermal energy from prompt fission and subsequent daughter decays)
Your multiplication with the energy conversion factor was executed correctly, but this value is affected by the incorrect mass defect from Step 1.
- Step 3
- Step 4Correct
Your division formula was correct, but your result is higher than expected due to the underestimated energy per fission event.
- Step 5Correct
You correctly applied the relationship between particle count, Avogadro's number, and molar mass, but the final numerical value carries over the earlier error.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly related electrical power output to thermal power input using the conversion efficiency.
You accurately calculated the total seconds in one day to determine the total required energy.
You correctly structured the conversion from required total energy to the number of fission events and molar mass.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeNo, this is a conceptual tracking error rather than a simple arithmetic slip because the incident neutron was completely missing from the reactant side of your mass balance equation.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the nuclear reaction as spontaneous fission of producing three neutrons, rather than induced fission where one incident neutron is captured by before fission occurs. Writing requires including on the reactant side, which simplifies to subtracting only neutron masses from .
REASONING PATH
Your ACEpath teacher’s suggested approach- Balancing Reactants and Products in $\Delta m$
Always write out the complete reactant mass sum and product mass sum before simplifying, ensuring that incident projectile particles like are not omitted.
- Net Neutron Production Check
In an induced reaction with incident neutron and emitted neutrons, simplify the neutron contribution to subtracting from the heavy nucleus mass.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the correct net mass defect: .
Determine the total usable thermal energy released per fission event in an operating reactor (including prompt and delayed radiation from fragment decays): .
Calculate the daily number of fissions: .
Convert the number of fissions to mass of consumed: .
03 The student omits the seconds-per-day conversion factor and calculates energy per second instead of per day.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You treated the thermal power () directly as total daily energy without multiplying by the time elapsed in one day (). As a result, your value represents fissions per second rather than fissions per day.
- Step 4Correct
(to depending on prompt vs. total recoverable energy)
Your method of converting the number of nuclei to moles and then kilograms using molar mass was correct, but the final numerical value is off by a factor of due to the earlier omitted time factor.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the mass defect by accounting for the net production of two neutrons.
You successfully converted the mass defect to energy per fission using the provided conversion factor.
You correctly related electrical power and thermal efficiency to find thermal power .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou treated the power value in watts () as energy in joules without multiplying by the seconds in one day ().
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConflating instantaneous power (rate of energy production in ) with total cumulative energy (in ) over an extended time interval ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Power to Energy Dimensional Check
, where . A day contains .
Always write out explicit units when equating power and energy, confirming that time units cancel out into pure joules before calculating total reaction counts.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate total thermal energy required per day: .
Find total fissions required per day using the total recoverable energy per fission (): .
Convert number of consumed nuclei to mass: .
Lock it in
How are thermal power input (), electrical power output (), and thermal efficiency () related?
, which rearranges to . Since , input thermal power is always greater than output electrical power.
Similar question
A coal-fired power station generates of electrical power with an operating efficiency of . Calculate the thermal energy input required per hour, in gigajoules ().
Answer
. Key steps: ; .
A nuclear reactor provides of electric power at efficiency. If each fission event releases (), how many fissions must occur per second?
Answer
. Key steps: ; .
A research submarine reactor operates at thermal power and consumes of over a mission. Assuming all consumed nuclei undergo fission, calculate the average recoverable energy released per fission event in ().
Answer
. Key steps: Total energy ; total nuclei ; energy per fission .