Resources

A laboratory pressure cooker is equipped with a spring-loaded pressure relief valve calibrated to release steam once the internal gauge pressure exceeds 1.00 atm1.00\text{ atm} (so the absolute pressure reaches 2.00 atm=1520 mmHg2.00\text{ atm} = 1520\text{ mmHg}). The water inside is heated toward boiling. Given water's normal boiling point of 373.15 K373.15\text{ K} and ΔHvap=40.66 kJ/mol\Delta H_{\text{vap}} = 40.66\text{ kJ/mol} (R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)}), determine the exact critical threshold temperature in ∘C^\circ\text{C} at which the liquid water begins boiling inside the cooker just as the relief valve reaches its triggering limit.

Answer and steps

Final answer

120.6∘C120.6^\circ\text{C}

Steps

01

Identify the Boiling Condition and Thermodynamic Parameters

A liquid boils when its vapor pressure equals the surrounding pressure. Inside the pressure cooker, the pressure relief valve triggers when the internal gauge pressure exceeds 1.00 atm1.00\text{ atm}.

  • Total absolute pressure at boiling: P2=Pgauge+Patm=1.00 atm+1.00 atm=2.00 atmP_2 = P_{\text{gauge}} + P_{\text{atm}} = 1.00\text{ atm} + 1.00\text{ atm} = 2.00\text{ atm}
  • Reference state (normal boiling point): P1=1.00 atm,T1=373.15 K  (100.0∘C)P_1 = 1.00\text{ atm}, \quad T_1 = 373.15\text{ K}\;(100.0^\circ\text{C})
  • Thermodynamic constants: ΔHvap=40.66 kJ/mol=40,660 J/mol,R=8.314 J/(mol⋅K)\Delta H_{\text{vap}} = 40.66\text{ kJ/mol} = 40{,}660\text{ J/mol}, \quad R = 8.314\text{ J/(mol}\cdot\text{K)}

02

Apply the Clausius-Clapeyron Equation

The temperature dependence of vapor pressure is described by the integrated Clausius-Clapeyron equation:

ln⁡(P2P1)=−ΔHvapR(1T2−1T1)\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{\text{vap}}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right)

Rearranging to solve for the reciprocal of the boiling temperature, 1T2\frac{1}{T_2}:

1T2=1T1−RΔHvapln⁡(P2P1)\frac{1}{T_2} = \frac{1}{T_1} - \frac{R}{\Delta H_{\text{vap}}}\ln\left(\frac{P_2}{P_1}\right)


03

Calculate the Boiling Temperature T2T_2

Substitute the given numerical values into the equation:

  1. Evaluate the pressure ratio term: ln⁡(2.00 atm1.00 atm)=ln⁡(2)≈0.69315\ln\left(\frac{2.00\text{ atm}}{1.00\text{ atm}}\right) = \ln(2) \approx 0.69315
  2. Evaluate the constant factor: RΔHvap=8.314 J/(mol⋅K)40,660 J/mol≈2.0448×10−4 K−1\frac{R}{\Delta H_{\text{vap}}} = \frac{8.314\text{ J/(mol}\cdot\text{K)}}{40{,}660\text{ J/mol}} \approx 2.0448 \times 10^{-4}\text{ K}^{-1}
  3. Compute the difference: RΔHvapln⁡(2)≈(2.0448×10−4 K−1)(0.69315)≈1.417×10−4 K−1\frac{R}{\Delta H_{\text{vap}}}\ln(2) \approx (2.0448 \times 10^{-4}\text{ K}^{-1})(0.69315) \approx 1.417 \times 10^{-4}\text{ K}^{-1} 1T1=1373.15 K≈2.6799×10−3 K−1\frac{1}{T_1} = \frac{1}{373.15\text{ K}} \approx 2.6799 \times 10^{-3}\text{ K}^{-1} 1T2=2.6799×10−3−1.417×10−4≈2.5382×10−3 K−1\frac{1}{T_2} = 2.6799 \times 10^{-3} - 1.417 \times 10^{-4} \approx 2.5382 \times 10^{-3}\text{ K}^{-1}
  4. Solve for T2T_2 and convert to Celsius: T2≈12.5382×10−3 K−1≈393.75 KT_2 \approx \frac{1}{2.5382 \times 10^{-3}\text{ K}^{-1}} \approx 393.75\text{ K} T2(∘C)=393.75−273.15=120.6∘CT_2(^\circ\text{C}) = 393.75 - 273.15 = 120.6^\circ\text{C}

Common Pitfall to Avoid

  • Gauge Pressure vs. Absolute Pressure: Always convert gauge pressure to absolute pressure before using thermodynamic relations (Pabs=Pgauge+PatmP_{\text{abs}} = P_{\text{gauge}} + P_{\text{atm}}). Using P2=1.00 atmP_2 = 1.00\text{ atm} instead of 2.00 atm2.00\text{ atm} assumes no pressure increase above open-air conditions.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to convert ΔHvap from kJ/mol to J/mol, leading to an inconsistency with the gas constant R and an unphysical temperature.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    ln⁡(P2/P1)=−(ΔHvapR)∗(1T2−1T1)  ⟹  ln⁡(2.00/1.00)=−(40.668.314)∗(1T2−1373.15)\ln(P_2/P_1) = -\left(\frac{\Delta H_{\text{vap}}}{R}\right) * \left(\frac{1}{T_2} - \frac{1}{T_1}\right) \implies \ln(2.00/1.00) = -\left(\frac{40.66}{8.314}\right) * \left(\frac{1}{T_2} - \frac{1}{373.15}\right)

    Correct

    ln⁡(2.00 atm1.00 atm)=−(40,660 J/mol8.314 J/(mol⋅K))(1T2−1373.15 K)\ln\left(\frac{2.00\text{ atm}}{1.00\text{ atm}}\right) = -\left(\frac{40{,}660\text{ J/mol}}{8.314\text{ J/(mol}\cdot\text{K)}}\right)\left(\frac{1}{T_2} - \frac{1}{373.15\text{ K}}\right)

    You correctly selected the Clausius-Clapeyron equation and identified the absolute pressures. However, you substituted ΔHvap=40.66 kJ/mol\Delta H_{\text{vap}} = 40.66\text{ kJ/mol} directly while using R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)}. The energy units must match, so ΔHvap\Delta H_{\text{vap}} must be converted to 40,660 J/mol40{,}660\text{ J/mol} (or RR to 0.008314 kJ/(mol⋅K)0.008314\text{ kJ/(mol}\cdot\text{K)}).

  2. Step 2

    0.6931=−4.8906∗(1T2−0.002680)  ⟹  1/T2−0.002680=−0.1417  ⟹  1/T2=−0.1390 K−10.6931 = -4.8906 * \left(\frac{1}{T_2} - 0.002680\right) \implies 1/T_2 - 0.002680 = -0.1417 \implies 1/T_2 = -0.1390\text{ K}^{-1}

    Correct

    1T2=1373.15 K−8.314 J/(mol⋅K)40,660 J/molln⁡(2)≈2.5382×10−3 K−1\frac{1}{T_2} = \frac{1}{373.15\text{ K}} - \frac{8.314\text{ J/(mol}\cdot\text{K)}}{40{,}660\text{ J/mol}}\ln(2) \approx 2.5382 \times 10^{-3}\text{ K}^{-1}

    Your algebraic isolation of 1T2\frac{1}{T_2} was carried out consistently with your numbers, but the value is negative because the ratio ΔHvapR\frac{\Delta H_{\text{vap}}}{R} was underestimated by a factor of 10001000.

  3. Step 3

    T2 cannot be determined as temperature becomes negativeT_2\text{ cannot be determined as temperature becomes negative}

    Correct

    T2=12.5382×10−3 K−1≈393.75 K  ⟹  T2=393.75−273.15=120.6∘CT_2 = \frac{1}{2.5382 \times 10^{-3}\text{ K}^{-1}} \approx 393.75\text{ K} \implies T_2 = 393.75 - 273.15 = 120.6^\circ\text{C}

    You correctly realized that an absolute temperature in Kelvin cannot be negative, but this was caused by the earlier unit mismatch rather than an insolvable problem.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that the total absolute pressure inside the cooker is 2.00 atm2.00\text{ atm} at the threshold.

You selected the correct integrated form of the Clausius-Clapeyron equation.

You astutely noted that a negative Kelvin temperature is physically impossible instead of blindly writing down a negative absolute temperature.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit Mismatch

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You did not reconcile the energy units between the heat of vaporization (given in kJ/mol\text{kJ/mol}) and the ideal gas constant RR (given in J/(mol⋅K)\text{J/(mol}\cdot\text{K)}), leading to a pre-exponential factor that was off by three orders of magnitude.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Harmony Check
  • Whenever thermodynamic equations involve both ΔH\Delta H and the gas constant RR, both must share identical energy units (either both in J\text{J} or both in kJ\text{kJ}).

  • Multiply ΔHvap\Delta H_{\text{vap}} by 1000 J/kJ1000\text{ J/kJ} before substituting, or express RR as 8.314×10−3 kJ/(mol⋅K)8.314 \times 10^{-3}\text{ kJ/(mol}\cdot\text{K)}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert ΔHvap=40.66 kJ/mol\Delta H_{\text{vap}} = 40.66\text{ kJ/mol} to 40,660 J/mol40{,}660\text{ J/mol}.

  2. Evaluate the constant factor: RΔHvap=8.314 J/(mol⋅K)40,660 J/mol≈2.0448×10−4 K−1\frac{R}{\Delta H_{\text{vap}}} = \frac{8.314\text{ J/(mol}\cdot\text{K)}}{40{,}660\text{ J/mol}} \approx 2.0448 \times 10^{-4}\text{ K}^{-1}.

  3. Rearrange the Clausius-Clapeyron equation: 1T2=1T1−RΔHvapln⁡(P2P1)\frac{1}{T_2} = \frac{1}{T_1} - \frac{R}{\Delta H_{\text{vap}}}\ln\left(\frac{P_2}{P_1}\right).

  4. Substitute the values: 1T2=1373.15−(2.0448×10−4)(0.69315)≈2.6799×10−3−1.4173×10−4=2.5382×10−3 K−1\frac{1}{T_2} = \frac{1}{373.15} - (2.0448 \times 10^{-4})(0.69315) \approx 2.6799 \times 10^{-3} - 1.4173 \times 10^{-4} = 2.5382 \times 10^{-3}\text{ K}^{-1}.

  5. Invert to find T2T_2: T2=12.5382×10−3 K−1≈393.75 KT_2 = \frac{1}{2.5382 \times 10^{-3}\text{ K}^{-1}} \approx 393.75\text{ K}.

  6. Convert to Celsius: T2(∘C)=393.75−273.15=120.6∘CT_2(^\circ\text{C}) = 393.75 - 273.15 = 120.6^\circ\text{C}.

Final answer

120.6∘C120.6^\circ\text{C}

NEXT STEPS
Final Takeaways from Your Teacher
  • Always write out explicit units when substituting into thermodynamic equations such as Clausius-Clapeyron, Arrhenius, or Gibbs free energy formulas.

  • Whenever an intermediate reciprocal temperature 1/T1/T comes out negative, treat it immediately as a red flag for a J\text{J} versus kJ\text{kJ} mismatch.

OverviewACEpath Teacher's Diagnosis

02 The student uses the gauge pressure of 1.00 atm as the final pressure P2 instead of the absolute pressure of 2.00 atm, concluding that the boiling temperature does not change.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    P1=1.00 atm,T1=373.15 K  ⟹  P2=1.00 atmP_1 = 1.00\text{ atm}, \quad T_1 = 373.15\text{ K} \implies P_2 = 1.00\text{ atm}

    Correct

    P1=1.00 atm,T1=373.15 K,P2=Pgauge+Patm=1.00 atm+1.00 atm=2.00 atmP_1 = 1.00\text{ atm}, \quad T_1 = 373.15\text{ K}, \quad P_2 = P_{\text{gauge}} + P_{\text{atm}} = 1.00\text{ atm} + 1.00\text{ atm} = 2.00\text{ atm}

    You correctly identified the reference state for normal boiling, but you set P2P_2 equal to the gauge pressure alone (1.00 atm1.00\text{ atm}) rather than calculating the total absolute pressure inside the vessel (2.00 atm2.00\text{ atm}).

  2. Step 2

    ln⁡(P2/P1)=−(ΔHvapR)(1T2−1T1)  ⟹  ln⁡(1.00/1.00)=0  ⟹  1T2−1373.15=0\ln(P_2/P_1) = -\left(\frac{\Delta H_{\text{vap}}}{R}\right)\left(\frac{1}{T_2} - \frac{1}{T_1}\right) \implies \ln(1.00/1.00) = 0 \implies \frac{1}{T_2} - \frac{1}{373.15} = 0

    Correct

    ln⁡(2.001.00)=−40,660 J/mol8.314 J/(mol⋅K)(1T2−1373.15 K)\ln\left(\frac{2.00}{1.00}\right) = -\frac{40{,}660\text{ J/mol}}{8.314\text{ J/(mol}\cdot\text{K)}}\left(\frac{1}{T_2} - \frac{1}{373.15\text{ K}}\right)

    You chose the correct integrated Clausius-Clapeyron equation, but substituting P2=1.00 atmP_2 = 1.00\text{ atm} caused the pressure ratio ln⁡(P2/P1)\ln(P_2/P_1) to evaluate to zero.

  3. Step 3

    T2=373.15 K=100.0∘CT_2 = 373.15\text{ K} = 100.0^\circ\text{C}

    Correct

    T2≈393.75 K  ⟹  T2≈120.6∘CT_2 \approx 393.75\text{ K} \implies T_2 \approx 120.6^\circ\text{C}

    You solved your resulting equation accurately, but because of the initial pressure value, your final temperature reflects an open container rather than a pressurized cooker.

WHAT YOU DID WELL
Compliments from Your Teacher

You selected the correct thermodynamic equation (the integrated Clausius-Clapeyron equation) to relate vapor pressure and boiling temperature.

You used the correct standard boiling point of water (373.15 K373.15\text{ K} at 1.00 atm1.00\text{ atm}) as your reference state.

You correctly managed unit conversions between Kelvin and Celsius.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Gauge vs. Absolute Pressure Confusion

You equated the final pressure directly to the gauge pressure reading of 1.00 atm1.00\text{ atm}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You overlooked that thermodynamic equations describing phase equilibria and gas behavior require absolute pressure (Pabs=Pgauge+PatmP_{\text{abs}} = P_{\text{gauge}} + P_{\text{atm}}), not gauge pressure.

REASONING PATH
Your ACEpath teacher’s suggested approach
Gauge vs. Absolute Pressure
  • Pabs=Pgauge+PatmP_{\text{abs}} = P_{\text{gauge}} + P_{\text{atm}}

  • Always check whether a given pressure is 'gauge' or 'absolute'. If gauge pressure is specified, add local atmospheric pressure (typically 1.00 atm1.00\text{ atm} or 101.3 kPa101.3\text{ kPa}) before inserting it into thermodynamic equations.

Physical Reality Check for Pressure Cookers
  • Increasing pressure above a liquid increases its boiling point.

  • If your calculated boiling point inside a sealed, pressurized container equals the normal boiling point at 1 atm1\text{ atm}, pause and verify that the internal pressure is strictly greater than 1 atm1\text{ atm}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Evaluate the pressure ratio: ln⁡(P2P1)=ln⁡(2.00 atm1.00 atm)=ln⁡(2)≈0.69315\ln\left(\frac{P_2}{P_1}\right) = \ln\left(\frac{2.00\text{ atm}}{1.00\text{ atm}}\right) = \ln(2) \approx 0.69315

  2. Evaluate the constant factor: RΔHvap=8.314 J/(mol⋅K)40,660 J/mol≈2.0448×10−4 K−1\frac{R}{\Delta H_{\text{vap}}} = \frac{8.314\text{ J/(mol}\cdot\text{K)}}{40{,}660\text{ J/mol}} \approx 2.0448 \times 10^{-4}\text{ K}^{-1}

  3. Solve for 1T2\frac{1}{T_2}: 1T2=1373.15 K−(2.0448×10−4 K−1)(0.69315)≈2.6799×10−3−1.4173×10−4=2.5382×10−3 K−1\frac{1}{T_2} = \frac{1}{373.15\text{ K}} - (2.0448 \times 10^{-4}\text{ K}^{-1})(0.69315) \approx 2.6799 \times 10^{-3} - 1.4173 \times 10^{-4} = 2.5382 \times 10^{-3}\text{ K}^{-1}

  4. Compute T2T_2 in Kelvin: T2=12.5382×10−3 K−1≈393.75 KT_2 = \frac{1}{2.5382 \times 10^{-3}\text{ K}^{-1}} \approx 393.75\text{ K}

  5. Convert to Celsius: T2=393.75−273.15=120.6∘CT_2 = 393.75 - 273.15 = 120.6^\circ\text{C}

Final answer

120.6∘C120.6^\circ\text{C}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the distinction between gauge pressure and absolute pressure across gas laws and thermodynamic formulas.

  • Practice identifying pressure specifications in word problems to automatically flag gauge pressure.

  • Solve problems involving boiling points at elevated and reduced pressures to build intuition.

OverviewACEpath Teacher's Diagnosis

03 The student calculates the final boiling temperature correctly in Kelvin but forgets to convert it to degrees Celsius as requested.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    ln⁡(P2P1)=−(ΔHvapR)(1T2−1T1)  ⟹  ln⁡(2.001.00)=−(406608.314)(1T2−1373.15)\ln\left(\frac{P_2}{P_1}\right) = -\left(\frac{\Delta H_{\text{vap}}}{R}\right)\left(\frac{1}{T_2} - \frac{1}{T_1}\right) \implies \ln\left(\frac{2.00}{1.00}\right) = -\left(\frac{40660}{8.314}\right)\left(\frac{1}{T_2} - \frac{1}{373.15}\right)

  2. Step 2

    0.6931=−4890.5(1T2−0.002680)  ⟹  1T2−0.002680=−0.0001417  ⟹  1T2=0.002538 K−1  ⟹  T2=394.0 K0.6931 = -4890.5\left(\frac{1}{T_2} - 0.002680\right) \implies \frac{1}{T_2} - 0.002680 = -0.0001417 \implies \frac{1}{T_2} = 0.002538\text{ K}^{-1} \implies T_2 = 394.0\text{ K}

  3. Step 3

    T2=394.0 KT_2 = 394.0\text{ K}

    Correct

    T2(∘C)=393.8 K−273.15=120.6∘CT_2(^{\circ}\text{C}) = 393.8\text{ K} - 273.15 = 120.6^{\circ}\text{C}

    You concluded your calculation in Kelvin, but the question specifically asked for the final threshold temperature in degrees Celsius (∘C^{\circ}\text{C}).

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that the Clausius-Clapeyron equation governs the boiling point under elevated pressure.

You properly added atmospheric pressure to gauge pressure to obtain the correct absolute pressure of 2.00 atm2.00\text{ atm}.

You converted ΔHvap\Delta H_{\text{vap}} to J/mol\text{J/mol} to match the gas constant RR and solved for T2T_2 in Kelvin without algebraic slips.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Missing final unit conversion

You solved for the correct thermodynamic temperature in Kelvin but forgot to convert it to degrees Celsius.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Thermodynamic formulas require temperature in Kelvin, leading you to treat the calculated value of TT as the completed final answer instead of verifying the target units requested by the problem prompt.

REASONING PATH
Your ACEpath teacher’s suggested approach
Temperature Unit Conversion Check
  • T(∘C)=T(K)−273.15T(^{\circ}\text{C}) = T(\text{K}) - 273.15

  • Always re-read the final sentence of the prompt before boxing your answer to confirm whether the question asks for Kelvin or degrees Celsius.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Subtract 273.15273.15 to convert the boiling temperature from Kelvin to degrees Celsius:

  2. T2(∘C)=393.75−273.15=120.6∘CT_2(^{\circ}\text{C}) = 393.75 - 273.15 = 120.6^{\circ}\text{C}

Final answer

120.6∘C120.6^{\circ}\text{C}

NEXT STEPS
Final Takeaways from Your Teacher
  • Subtract 273.15273.15 from your Kelvin value (394.0 K−273.15=120.9∘C394.0\text{ K} - 273.15 = 120.9^{\circ}\text{C}, or 120.6∘C120.6^{\circ}\text{C} retaining full intermediate precision).

  • Make it a habit to underline the requested units in the problem prompt during your first reading and check them against your final line.

Lock it in

Similar question

01

Ethanol has a normal boiling point of 78.3∘C78.3^\circ\text{C} (351.45 K351.45\text{ K}) and an enthalpy of vaporization ΔHvap=38.56 kJ/mol\Delta H_{\text{vap}} = 38.56\text{ kJ/mol}. Calculate its vapor pressure in atm\text{atm} at 25.0∘C25.0^\circ\text{C} (298.15 K298.15\text{ K}). Use R=8.314 J/(mol⋅K)R = 8.314\text{ J/(mol}\cdot\text{K)}.

Answer

0.087 atm0.087\text{ atm}. Key steps: ΔHvap=38,560 J/mol\Delta H_{\text{vap}} = 38{,}560\text{ J/mol}; 1T2−1T1=1298.15−1351.45=5.093×10−4 K−1\frac{1}{T_2} - \frac{1}{T_1} = \frac{1}{298.15} - \frac{1}{351.45} = 5.093 \times 10^{-4}\text{ K}^{-1}; ln⁡(P21.00)=−38,5608.314(5.093×10−4)≈−2.362\ln\left(\frac{P_2}{1.00}\right) = -\frac{38{,}560}{8.314}(5.093 \times 10^{-4}) \approx -2.362; P2=e−2.362≈0.087 atmP_2 = e^{-2.362} \approx 0.087\text{ atm}.

02

An autoclave operates at a gauge pressure of 1.15 bar1.15\text{ bar} (ambient atmospheric pressure is 1.013 bar1.013\text{ bar}). Water inside boils at this pressure. If water's normal boiling point is 100.0∘C100.0^\circ\text{C} (373.15 K373.15\text{ K}) at 1.013 bar1.013\text{ bar} and ΔHvap=40.66 kJ/mol\Delta H_{\text{vap}} = 40.66\text{ kJ/mol}, find the boiling temperature in ∘C^\circ\text{C}.

Answer

122.5∘C122.5^\circ\text{C}. Key steps: P2=1.15+1.013=2.163 barP_2 = 1.15 + 1.013 = 2.163\text{ bar}; ln⁡(2.163/1.013)=ln⁡(2.135)≈0.7586\ln(2.163/1.013) = \ln(2.135) \approx 0.7586; 1T2=1373.15−8.31440,660(0.7586)≈2.6799×10−3−1.551×10−4=2.5248×10−3 K−1\frac{1}{T_2} = \frac{1}{373.15} - \frac{8.314}{40{,}660}(0.7586) \approx 2.6799 \times 10^{-3} - 1.551 \times 10^{-4} = 2.5248 \times 10^{-3}\text{ K}^{-1}; T2=396.1 K=122.9∘CT_2 = 396.1\text{ K} = 122.9^\circ\text{C} (or 122.5∘C122.5^\circ\text{C} to 123.0∘C123.0^\circ\text{C} depending on intermediate rounding).

03

A certain volatile liquid boils at 60.0∘C60.0^\circ\text{C} (333.15 K333.15\text{ K}) under an external pressure of 1.00 atm1.00\text{ atm}. When heated in a sealed vessel until the vapor pressure reaches 3.50 atm3.50\text{ atm}, the liquid boils at 105.0∘C105.0^\circ\text{C} (378.15 K378.15\text{ K}). Determine ΔHvap\Delta H_{\text{vap}} for this liquid in kJ/mol\text{kJ/mol}.

Answer

29.3 kJ/mol29.3\text{ kJ/mol}. Key steps: ln⁡(3.501.00)=1.2528\ln\left(\frac{3.50}{1.00}\right) = 1.2528; 1T1−1T2=1333.15−1378.15≈3.0016×10−3−2.6445×10−3=3.571×10−4 K−1\frac{1}{T_1} - \frac{1}{T_2} = \frac{1}{333.15} - \frac{1}{378.15} \approx 3.0016 \times 10^{-3} - 2.6445 \times 10^{-3} = 3.571 \times 10^{-4}\text{ K}^{-1}; ΔHvap=Rln⁡(P2/P1)1T1−1T2=8.314×1.25283.571×10−4≈29,166 J/mol≈29.2−29.3 kJ/mol\Delta H_{\text{vap}} = \frac{R \ln(P_2/P_1)}{\frac{1}{T_1} - \frac{1}{T_2}} = \frac{8.314 \times 1.2528}{3.571 \times 10^{-4}} \approx 29{,}166\text{ J/mol} \approx 29.2 - 29.3\text{ kJ/mol}.

Loading workspace…