Resources

A standard electrochemical cell is constructed at 298 K298\text{ K} using a zinc strip immersed in a 1.00 M Zn(NO3)21.00\text{ M }\text{Zn(NO}_3\text{)}_2 solution and a copper strip immersed in a 1.00 M Cu(NO3)21.00\text{ M }\text{Cu(NO}_3\text{)}_2 solution, connected by a salt bridge and an external wire with a voltmeter. The standard reduction potentials are E∘=−0.76 VE^\circ = -0.76\text{ V} for Zn2+(aq)+2e−→Zn(s)\text{Zn}^{2+}\text{(aq)} + 2e^- \rightarrow \text{Zn(s)} and E∘=+0.34 VE^\circ = +0.34\text{ V} for Cu2+(aq)+2e−→Cu(s)\text{Cu}^{2+}\text{(aq)} + 2e^- \rightarrow \text{Cu(s)}. (a) Classify this operating cell as galvanic or electrolytic. (b) Identify the anode and the cathode. (c) Calculate the standard cell potential (Ecell∘E^\circ_{\text{cell}}) and determine whether the overall reaction is spontaneous under standard conditions.

Answer and steps

Final answer

(a) Galvanic cell; (b) Anode: Zn(s)\text{Zn(s)}, Cathode: Cu(s)\text{Cu(s)}; (c) Ecell∘=+1.10 VE^\circ_{\text{cell}} = +1.10\text{ V}, spontaneous (ΔG∘<0\Delta G^\circ < 0).

Steps

01

Compare standard reduction potentials to identify oxidation and reduction

The given standard reduction potentials are:

  • CuX2+(aq)+2 eX−→Cu(s)E∘=+0.34 V\ce{Cu^{2+}(aq) + 2e^- -> Cu(s)} \quad E^\circ = +0.34\text{ V}
  • ZnX2+(aq)+2 eX−→Zn(s)E∘=−0.76 V\ce{Zn^{2+}(aq) + 2e^- -> Zn(s)} \quad E^\circ = -0.76\text{ V}

A higher (more positive) reduction potential indicates a greater tendency to gain electrons (undergo reduction). Because +0.34 V>−0.76 V+0.34\text{ V} > -0.76\text{ V}, CuX2+\ce{Cu^{2+}} is reduced and metallic Zn\ce{Zn} is oxidized:

  • Cathode (reduction): CuX2+(aq)+2 eX−→Cu(s)\ce{Cu^{2+}(aq) + 2e^- -> Cu(s)}
  • Anode (oxidation): Zn(s)→ZnX2+(aq)+2 eX−\ce{Zn(s) -> Zn^{2+}(aq) + 2e^-}

Therefore:

  • Anode: Zn(s)\ce{Zn(s)}
  • Cathode: Cu(s)\ce{Cu(s)}
02

Calculate the standard cell potential (Ecell∘E^\circ_{\text{cell}})

Using standard reduction potentials: Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}

Substitute the given values: Ecell∘=+0.34 V−(−0.76 V)=+1.10 VE^\circ_{\text{cell}} = +0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}

Common Pitfall: When using the formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}, use the standard reduction potentials directly without manually flipping the sign of the anode potential beforehand; the subtraction sign in the equation already accounts for the reversal of the oxidation half-reaction.

03

Determine spontaneity and classify the cell

The relationship between standard Gibbs free energy change (ΔG∘\Delta G^\circ) and standard cell potential (Ecell∘E^\circ_{\text{cell}}) is: ΔG∘=−nFEcell∘\Delta G^\circ = -nFE^\circ_{\text{cell}}

Because Ecell∘=+1.10 V>0E^\circ_{\text{cell}} = +1.10\text{ V} > 0, the value of ΔG∘\Delta G^\circ is negative (ΔG∘<0\Delta G^\circ < 0). This confirms that the forward redox reaction is spontaneous under standard conditions.

  • An electrochemical cell that uses a spontaneous redox reaction (ΔG∘<0\Delta G^\circ < 0, Ecell∘>0E^\circ_{\text{cell}} > 0) to generate electrical energy across an external circuit is a galvanic (voltaic) cell.
  • In contrast, an electrolytic cell requires an external electrical power source to drive a non-spontaneous reaction.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student subtracts the cathode potential from the anode potential when calculating the cell potential, obtaining a negative voltage and mistakenly concluding the reaction is nonspontaneous.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Galvanic

  2. Step 2

    Anode: Zn ⟹ Cathode: Cu

  3. Step 3

    Ecell∘=Eanode∘−Ecathode∘  ⟹  Ecell∘=−0.76 V−0.34 V=−1.10 VE^\circ_{\text{cell}} = E^\circ_{\text{anode}} - E^\circ_{\text{cathode}} \implies E^\circ_{\text{cell}} = -0.76\text{ V} - 0.34\text{ V} = -1.10\text{ V}

    Correct

    Ecell∘=Ecathode∘−Eanode∘=+0.34 V−(−0.76 V)=+1.10 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}

    The standard reduction potential equation is Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}, not anode minus cathode. Subtracting the anode potential from the cathode potential yields +0.34 V−(−0.76 V)=+1.10 V+0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}.

  4. Step 4

    Nonspontaneous because Ecell∘<0E^\circ_{\text{cell}} < 0

    Correct

    Spontaneous under standard conditions because Ecell∘=+1.10 V>0E^\circ_{\text{cell}} = +1.10\text{ V} > 0 (and ΔG∘<0\Delta G^\circ < 0)

    Your reasoning that Ecell∘<0E^\circ_{\text{cell}} < 0 implies a nonspontaneous process is correct in principle, but because the cell potential is actually +1.10 V>0+1.10\text{ V} > 0, the forward reaction is spontaneous.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly classified the system as a galvanic cell.

You correctly identified the anode and cathode based on standard reduction potentials.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Reversed Cell Potential Formula

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You used the inverted relation Ecell∘=Eanode∘−Ecathode∘E^\circ_{\text{cell}} = E^\circ_{\text{anode}} - E^\circ_{\text{cathode}} instead of Ecathode∘−Eanode∘E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}. This reversed the sign of the overall voltage and caused you to conclude that the spontaneous galvanic process was nonspontaneous.

REASONING PATH
Your ACEpath teacher’s suggested approach
Cell Potential Formula
  • When calculating standard cell potential from standard reduction potentials, always compute cathode minus anode: Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  • Remember the mnemonic 'red cat' (reduction at cathode) and that reduction potential directly applies to the cathode, while the anode is subtracted because it is being oxidized.

Galvanic Spontaneity Consistency
  • A functional galvanic (voltaic) cell must have a positive cell voltage (Ecell∘>0E^\circ_{\text{cell}} > 0) corresponding to a spontaneous process (ΔG∘<0\Delta G^\circ < 0).

  • If you classify a cell as galvanic but obtain a negative Ecell∘E^\circ_{\text{cell}}, immediately check whether you reversed the cathode and anode in your formula.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the standard cell potential formula: Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  2. Substitute the standard reduction potentials: Ecell∘=+0.34 V−(−0.76 V)=+1.10 VE^\circ_{\text{cell}} = +0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}.

  3. Evaluate spontaneity: because Ecell∘=+1.10 V>0E^\circ_{\text{cell}} = +1.10\text{ V} > 0, ΔG∘=−nFEcell∘<0\Delta G^\circ = -nFE^\circ_{\text{cell}} < 0, meaning the reaction is spontaneous under standard conditions.

Final answer

(a) Galvanic cell; (b) Anode: Zn(s)\text{Zn(s)}, Cathode: Cu(s)\text{Cu(s)}; (c) Ecell∘=+1.10 VE^\circ_{\text{cell}} = +1.10\text{ V}, spontaneous.

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} and use it whenever values are given as standard reduction potentials.

  • Perform a sanity check on every galvanic cell: ensure that Ecell∘>0E^\circ_{\text{cell}} > 0 before reporting the final spontaneity.

OverviewACEpath Teacher's Diagnosis

02 The student reverses the assignments of anode and cathode, assuming the half-cell with the negative reduction potential must be the cathode.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Galvanic

  2. Step 2

    Anode: Cu\text{Cu} ⟹\Longrightarrow Cathode: Zn\text{Zn}

    Correct

    Anode: Zn(s)\text{Zn(s)} ⟹\Longrightarrow Cathode: Cu(s)\text{Cu(s)}

    The half-reaction with the higher reduction potential (+0.34 V>−0.76 V+0.34\text{ V} > -0.76\text{ V}) undergoes reduction at the cathode. Therefore, Cu\text{Cu} is the cathode and Zn\text{Zn} is the anode.

  3. Step 3

    Ecell0=Ecathode0−Eanode0⟹Ecell0=−0.76 V−0.34 V=−1.10 VE^0_{\text{cell}} = E^0_{\text{cathode}} - E^0_{\text{anode}} \Longrightarrow E^0_{\text{cell}} = -0.76\text{ V} - 0.34\text{ V} = -1.10\text{ V}

    Correct

    Ecell∘=Ecathode∘−Eanode∘⟹Ecell∘=+0.34 V−(−0.76 V)=+1.10 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} \Longrightarrow E^\circ_{\text{cell}} = +0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}

    Your formula and arithmetic are mathematically consistent with your reversed electrode assignments, but substituting the incorrect values led to a negative potential.

  4. Step 4

    Nonspontaneous because Ecell0<0E^0_{\text{cell}} < 0

    Correct

    Spontaneous because Ecell∘>0E^\circ_{\text{cell}} > 0

    Your logic that Ecell∘<0E^\circ_{\text{cell}} < 0 implies nonspontaneity is correct, but it relies directly on the negative potential calculated in the previous step.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly classified the electrochemical system as a galvanic cell.

You correctly recalled the standard cell potential formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

You correctly understood that the algebraic sign of Ecell∘E^\circ_{\text{cell}} dictates reaction spontaneity.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Reversed Anode and Cathode

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You assigned the electrode with the more negative reduction potential to the cathode rather than the anode. In a galvanic cell, reduction spontaneously occurs at the electrode with the more positive (higher) standard reduction potential.

REASONING PATH
Your ACEpath teacher’s suggested approach
Redox Spontaneity and Electrode Roles
  • In a galvanic cell, the half-cell with the more positive reduction potential (Ered∘E^\circ_{\text{red}}) undergoes reduction (Cathode: Red Cat), while the more negative one undergoes oxidation (Anode: An Ox).

  • Always compare the reduction potentials first: set the higher value as Ecathode∘E^\circ_{\text{cathode}} so that Ecell∘=Ecathode∘−Eanode∘>0E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} > 0.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Compare reduction potentials: +0.34 V>−0.76 V+0.34\text{ V} > -0.76\text{ V}, so Cu2+\text{Cu}^{2+} is reduced at the cathode and Zn\text{Zn} is oxidized at the anode.

  2. Calculate standard cell potential: Ecell∘=Ecathode∘−Eanode∘=+0.34 V−(−0.76 V)=+1.10 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}.

  3. Determine spontaneity: Since Ecell∘=+1.10 V>0E^\circ_{\text{cell}} = +1.10\text{ V} > 0, the forward reaction is spontaneous under standard conditions.

Final answer

(a) Galvanic cell; (b) Anode: Zn(s)\text{Zn(s)}, Cathode: Cu(s)\text{Cu(s)}; (c) Ecell∘=+1.10 VE^\circ_{\text{cell}} = +1.10\text{ V}, spontaneous

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the mnemonic 'Red Cat' (Reduction at Cathode) and 'An Ox' (Anode undergoes Oxidation).

  • Check that a galvanic cell always produces a positive Ecell∘E^\circ_{\text{cell}} when operating spontaneously.

OverviewACEpath Teacher's Diagnosis

03 The student adds the reduction potentials directly without changing the sign of the oxidation half-reaction or using E°cathode - E°anode, arriving at an incorrect cell potential of -0.42 V.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Galvanic  ⟹  Anode: Zn  ⟹  Cathode: Cu\text{Galvanic} \implies \text{Anode: Zn} \implies \text{Cathode: Cu}

  2. Step 2

    Ecell∘=E∘(Cu2+/Cu)+E∘(Zn2+/Zn)=+0.34 V+(−0.76 V)=−0.42 VE^\circ_{\text{cell}} = E^\circ(\text{Cu}^{2+}/\text{Cu}) + E^\circ(\text{Zn}^{2+}/\text{Zn}) = +0.34\text{ V} + (-0.76\text{ V}) = -0.42\text{ V}

    Correct

    Ecell∘=Ecathode∘−Eanode∘=+0.34 V−(−0.76 V)=+1.10 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}

    You directly added the standard reduction potentials. Because standard electrode tables provide reduction potentials, oxidation requires reversing the half-reaction sign (Eox∘=−Ered∘E^\circ_{\text{ox}} = -E^\circ_{\text{red}}) or using the standard formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  3. Step 3

    Nonspontaneous because Ecell∘<0\text{Nonspontaneous because } E^\circ_{\text{cell}} < 0

    Correct

    Spontaneous because Ecell∘=+1.10 V>0 (or ΔG∘<0)\text{Spontaneous because } E^\circ_{\text{cell}} = +1.10\text{ V} > 0 \text{ (or } \Delta G^\circ < 0\text{)}

    Your reasoning connecting a negative cell potential to non-spontaneity follows logically from your value, but the true cell potential is positive (+1.10 V+1.10\text{ V}), which makes the overall redox reaction spontaneous under standard conditions.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly compared the standard reduction potentials to determine the anode and cathode.

You correctly identified the cell as galvanic based on the spontaneous electrode combination.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Cell Potential Sign Convention Error

You summed the tabulated reduction potentials without accounting for the oxidation process at the anode.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the two valid methods for computing cell potentials: either sum reduction and oxidation potentials (Ecell∘=Ered∘+Eox∘E^\circ_{\text{cell}} = E^\circ_{\text{red}} + E^\circ_{\text{ox}} where Eox∘=−Ered, anode∘E^\circ_{\text{ox}} = -E^\circ_{\text{red, anode}}) or use tabulated reduction potentials directly via subtraction (Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Standard Reduction Formula
  • When using tabulated standard reduction potentials (Ered∘E^\circ_{\text{red}}), the formula is Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  • Keep the signs exactly as listed in the reduction table and subtract the anode value from the cathode value.

Galvanic Spontaneity Consistency
  • A functioning galvanic (voltaic) cell must have Ecell∘>0E^\circ_{\text{cell}} > 0 and ΔG∘<0\Delta G^\circ < 0.

  • Whenever you classify a cell as galvanic, verify that your calculated Ecell∘E^\circ_{\text{cell}} is positive.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Apply the standard reduction potential formula: Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  2. Substitute the given reduction potentials: Ecell∘=+0.34 V−(−0.76 V)=+1.10 VE^\circ_{\text{cell}} = +0.34\text{ V} - (-0.76\text{ V}) = +1.10\text{ V}.

  3. Because Ecell∘=+1.10 V>0E^\circ_{\text{cell}} = +1.10\text{ V} > 0, ΔG∘=−nFEcell∘<0\Delta G^\circ = -nFE^\circ_{\text{cell}} < 0, confirming the reaction is spontaneous under standard conditions.

Final answer

(a) Galvanic cell; (b) Anode: Zn(s)\text{Zn(s)}, Cathode: Cu(s)\text{Cu(s)}; (c) Ecell∘=+1.10 VE^\circ_{\text{cell}} = +1.10\text{ V}, spontaneous.

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice using Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} without altering the tabulated signs before subtraction.

  • Use the cell classification as a sanity check: galvanic cells always produce a positive Ecell∘E^\circ_{\text{cell}} under standard conditions.

Lock it in

Similar question

01

A standard electrochemical cell is built using a silver electrode (E∘(Ag+/Ag)=+0.80 VE^\circ(\text{Ag}^+/\text{Ag}) = +0.80\text{ V}) and an iron electrode (E∘(Fe2+/Fe)=−0.44 VE^\circ(\text{Fe}^{2+}/\text{Fe}) = -0.44\text{ V}). Calculate the standard cell potential Ecell∘E^\circ_{\text{cell}} and identify which metal serves as the cathode.

Answer

Cathode: Ag(s)\text{Ag(s)}, Ecell∘=+1.24 VE^\circ_{\text{cell}} = +1.24\text{ V}. Silver has the higher reduction potential (+0.80 V>−0.44 V+0.80\text{ V} > -0.44\text{ V}), so it undergoes reduction at the cathode. Then Ecell∘=Ecathode∘−Eanode∘=+0.80 V−(−0.44 V)=+1.24 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.80\text{ V} - (-0.44\text{ V}) = +1.24\text{ V}.

02

Consider a standard cell with cadmium and lead half-reactions: E∘(Cd2+/Cd)=−0.40 VE^\circ(\text{Cd}^{2+}/\text{Cd}) = -0.40\text{ V} and E∘(Pb2+/Pb)=−0.13 VE^\circ(\text{Pb}^{2+}/\text{Pb}) = -0.13\text{ V}. Write the balanced overall spontaneous cell reaction and calculate Ecell∘E^\circ_{\text{cell}}.

Answer

Overall reaction: Cd(s)+Pb2+(aq)→Cd2+(aq)+Pb(s)\text{Cd(s)} + \text{Pb}^{2+}\text{(aq)} \rightarrow \text{Cd}^{2+}\text{(aq)} + \text{Pb(s)}; Ecell∘=+0.27 VE^\circ_{\text{cell}} = +0.27\text{ V}. Since −0.13 V>−0.40 V-0.13\text{ V} > -0.40\text{ V}, Pb2+\text{Pb}^{2+} is reduced at the cathode and Cd\text{Cd} is oxidized at the anode. Ecell∘=−0.13 V−(−0.40 V)=+0.27 VE^\circ_{\text{cell}} = -0.13\text{ V} - (-0.40\text{ V}) = +0.27\text{ V}.

03

An engineer considers using an external power source to drive the reaction Cu(s)+2H+(aq)→Cu2+(aq)+H2(g)\text{Cu(s)} + 2\text{H}^+\text{(aq)} \rightarrow \text{Cu}^{2+}\text{(aq)} + \text{H}_2\text{(g)} under standard conditions (E∘(Cu2+/Cu)=+0.34 VE^\circ(\text{Cu}^{2+}/\text{Cu}) = +0.34\text{ V}, E∘(H+/H2)=0.00 VE^\circ(\text{H}^+/\text{H}_2) = 0.00\text{ V}). (a) Calculate Ecell∘E^\circ_{\text{cell}} for this process. (b) Classify the cell type required to make this reaction proceed.

Answer

(a) Ecell∘=−0.34 VE^\circ_{\text{cell}} = -0.34\text{ V}; (b) Electrolytic cell. Here, H+\text{H}^+ is reduced at the cathode (0.00 V0.00\text{ V}) and Cu\text{Cu} is oxidized at the anode (+0.34 V+0.34\text{ V}), giving Ecell∘=0.00 V−(+0.34 V)=−0.34 VE^\circ_{\text{cell}} = 0.00\text{ V} - (+0.34\text{ V}) = -0.34\text{ V}. Because Ecell∘<0E^\circ_{\text{cell}} < 0, the reaction is nonspontaneous and requires an electrolytic cell with an applied external voltage greater than 0.34 V0.34\text{ V}.

Loading workspace…