Resources

An aqueous sample of zinc reacts with excess hydrochloric acid, producing hydrogen gas that is collected over water in an inverted buret at 25.0∘C25.0^\circ\text{C} and a barometric pressure of 754.0 torr754.0\text{ torr}. The water level inside the buret is 6.80 cm6.80\text{ cm} higher than the exterior water surface, creating a hydrostatic head. At 25.0∘C25.0^\circ\text{C}, the vapor pressure of liquid water is 23.76 torr23.76\text{ torr}. Given that the density of water is 1.00 g/cm31.00\text{ g/cm}^3 and the density of mercury is 13.6 g/cm313.6\text{ g/cm}^3, determine whether the hydrostatic pressure correction exceeds the 0.50%0.50\% threshold of barometric pressure, and calculate the exact partial pressure of dry hydrogen gas (PH2P_{\text{H}_2}) in torr\text{torr}.

Answer and steps

Final answer

Hydrostatic correction=5.00 torr\text{Hydrostatic correction} = 5.00\text{ torr} (0.663%0.663\% of barometric pressure, exceeding the 0.50%0.50\% threshold); PH2=725.2 torrP_{\text{H}_2} = 725.2\text{ torr}

Steps

01

Calculate the Hydrostatic Pressure Correction

When gas is collected over water and the water column inside the buret is higher than the exterior water reservoir, the raised column exerts a downward hydrostatic pressure (PheadP_{\text{head}}).

To convert the height of the water column (hHX2Oh_{\ce{H2O}}) into an equivalent height of mercury in torr\text{torr} (mm Hg\text{mm Hg}), equate the hydrostatic pressures (ρHX2OghHX2O=ρHgghHg\rho_{\ce{H2O}} g h_{\ce{H2O}} = \rho_{\ce{Hg}} g h_{\ce{Hg}}):

hHg=hHX2O⋅ρHX2OρHgh_{\ce{Hg}} = h_{\ce{H2O}} \cdot \frac{\rho_{\ce{H2O}}}{\rho_{\ce{Hg}}}

Given hHX2O=6.80 cm=68.0 mmh_{\ce{H2O}} = 6.80\text{ cm} = 68.0\text{ mm}:

Phead=68.0 mm⋅1.00 g/cm313.6 g/cm3=5.00 mm Hg=5.00 torrP_{\text{head}} = 68.0\text{ mm} \cdot \frac{1.00\text{ g/cm}^3}{13.6\text{ g/cm}^3} = 5.00\text{ mm Hg} = 5.00\text{ torr}

02

Compare Against the 0.50%0.50\% Threshold

Evaluate the percentage of the atmospheric (barometric) pressure represented by this hydrostatic column:

Percentage=PheadPbar⋅100%=5.00 torr754.0 torr⋅100%≈0.663%\text{Percentage} = \frac{P_{\text{head}}}{P_{\text{bar}}} \cdot 100\% = \frac{5.00\text{ torr}}{754.0\text{ torr}} \cdot 100\% \approx 0.663\%

Because 0.663%>0.50%0.663\% > 0.50\%, the hydrostatic pressure correction exceeds the 0.50%0.50\% threshold and cannot be neglected in precision calculations.

03

Determine Total Gas Pressure Inside the Buret

At equilibrium, the pressure at the outer water surface equals atmospheric pressure:

Pbar=Ptotal, inside+PheadP_{\text{bar}} = P_{\text{total, inside}} + P_{\text{head}}

Rearranging to solve for the total gas pressure trapped inside the buret:

Ptotal, inside=Pbar−Phead=754.0 torr−5.00 torr=749.0 torrP_{\text{total, inside}} = P_{\text{bar}} - P_{\text{head}} = 754.0\text{ torr} - 5.00\text{ torr} = 749.0\text{ torr}

Common Pitfall: When the water level inside the buret is higher than outside, the hydrostatic column opposes the atmospheric pressure. Subtracting PheadP_{\text{head}} from PbarP_{\text{bar}} gives the gas pressure inside the buret; adding it would be a mistake.

04

Apply Dalton's Law to Find PHX2P_{\ce{H2}}

According to Dalton's law of partial pressures, the total gas inside the buret is a mixture of dry hydrogen gas and water vapor:

Ptotal, inside=PHX2+PHX2OP_{\text{total, inside}} = P_{\ce{H2}} + P_{\ce{H2O}}

Rearranging to find the partial pressure of dry hydrogen:

PHX2=Ptotal, inside−PHX2OP_{\ce{H2}} = P_{\text{total, inside}} - P_{\ce{H2O}}

Substitute the values:

PHX2=749.0 torr−23.76 torr=725.24 torr≈725.2 torrP_{\ce{H2}} = 749.0\text{ torr} - 23.76\text{ torr} = 725.24\text{ torr} \approx 725.2\text{ torr}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student adds the hydrostatic head pressure to the atmospheric pressure instead of subtracting it when the internal liquid level is higher than the exterior level.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    hHg=68.0 mm13.6=5.00 torrh_{\text{Hg}} = \frac{68.0\text{ mm}}{13.6} = 5.00\text{ torr}

  2. Step 2

    Threshold=0.0050×754.0 torr=3.77 torr  ⟹  5.00 torr>3.77 torr\text{Threshold} = 0.0050 \times 754.0\text{ torr} = 3.77\text{ torr} \implies 5.00\text{ torr} > 3.77\text{ torr}, so the correction exceeds the 0.50%0.50\% threshold.

  3. Step 3

    Ptotal=Patm+Ph=754.0 torr+5.00 torr=759.0 torrP_{\text{total}} = P_{\text{atm}} + P_h = 754.0\text{ torr} + 5.00\text{ torr} = 759.0\text{ torr}

    Correct

    Ptotal, inside=Patm−Phead=754.0 torr−5.00 torr=749.0 torrP_{\text{total, inside}} = P_{\text{atm}} - P_{\text{head}} = 754.0\text{ torr} - 5.00\text{ torr} = 749.0\text{ torr}

    When the water level inside the buret is higher than the outside water level, the elevated water column pulls downward against atmospheric pressure. The pressure balance at the exterior liquid level is Patm=Ptotal, inside+PheadP_{\text{atm}} = P_{\text{total, inside}} + P_{\text{head}}, meaning you must subtract PheadP_{\text{head}} from PatmP_{\text{atm}} to find Ptotal, insideP_{\text{total, inside}}.

  4. Step 4

    PH2=759.0 torr−23.76 torr=735.24 torrP_{\text{H}_2} = 759.0\text{ torr} - 23.76\text{ torr} = 735.24\text{ torr}

    Correct

    PH2=749.0 torr−23.76 torr=725.24 torr≈725.2 torrP_{\text{H}_2} = 749.0\text{ torr} - 23.76\text{ torr} = 725.24\text{ torr} \approx 725.2\text{ torr}

    You correctly applied Dalton's law by subtracting the water vapor pressure, but the value is inaccurate due to the sign error in Step 3.

WHAT YOU DID WELL
Compliments from Your Teacher

You converted the water column height to equivalent mercury height accurately.

You tested and stated whether the hydrostatic correction exceeded the 0.50% threshold correctly.

You identified that Dalton's law requires subtracting the vapor pressure of water to isolate the dry gas.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Hydrostatic head sign error

You set Ptotal=Patm+PhP_{\text{total}} = P_{\text{atm}} + P_h instead of Ptotal=Patm−PhP_{\text{total}} = P_{\text{atm}} - P_h.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the direction of hydrostatic pressure when an inverted column is raised versus submerged below the external surface. A liquid column suspended above the reservoir level acts in the same downward direction as the trapped gas pressure, requiring the gas pressure inside to be lower than atmospheric pressure.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check liquid level reference
  • At the surface of the open reservoir, pressure is equal inside and outside: Patm=Pinside+Pliquid columnP_{\text{atm}} = P_{\text{inside}} + P_{\text{liquid column}}.

  • If the inner liquid level is HIGHER than the outside water level, subtract PheadP_{\text{head}} (Pgas, total=Patm−PheadP_{\text{gas, total}} = P_{\text{atm}} - P_{\text{head}}). If the inner level is LOWER, add PheadP_{\text{head}} (Pgas, total=Patm+PheadP_{\text{gas, total}} = P_{\text{atm}} + P_{\text{head}}).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the pressure balance at the exterior water level: Patm=Ptotal, inside+PheadP_{\text{atm}} = P_{\text{total, inside}} + P_{\text{head}}

  2. Solve for the total gas pressure inside the buret: Ptotal, inside=754.0 torr−5.00 torr=749.0 torrP_{\text{total, inside}} = 754.0\text{ torr} - 5.00\text{ torr} = 749.0\text{ torr}

  3. Apply Dalton's law of partial pressures: PH2=Ptotal, inside−PH2O=749.0 torr−23.76 torr=725.24 torrP_{\text{H}_2} = P_{\text{total, inside}} - P_{\text{H}_2\text{O}} = 749.0\text{ torr} - 23.76\text{ torr} = 725.24\text{ torr}

Final answer

725.2 torr725.2\text{ torr}

NEXT STEPS
Final Takeaways from Your Teacher
  • Sketch the gas collection apparatus and draw opposing pressure arrows at the reference line to verify whether the column helps or opposes atmospheric pressure.

  • Remember the memory aid: 'Level higher →\rightarrow gas pressure lower than atmospheric; level lower →\rightarrow gas pressure higher than atmospheric.'

  • Practice solving inverted gas collection problems with both positive and negative liquid level offsets.

OverviewACEpath Teacher's Diagnosis

02 The student neglects to convert the hydrostatic height of water into equivalent mmHg using the ratio of densities, using 68.0 torr directly as the hydrostatic pressure.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Ph=6.80 cm=68.0 mm=68.0 torrP_h = 6.80\text{ cm} = 68.0\text{ mm} = 68.0\text{ torr}

    Correct

    Phead=68.0 mm H2O×1.00 g/cm313.6 g/cm3=5.00 mm Hg=5.00 torrP_{\text{head}} = 68.0\text{ mm H}_2\text{O} \times \frac{1.00\text{ g/cm}^3}{13.6\text{ g/cm}^3} = 5.00\text{ mm Hg} = 5.00\text{ torr}

    You converted centimeters to millimeters correctly, but 1 torr1\text{ torr} is defined as 1 mm Hg1\text{ mm Hg}, not 1 mm H2O1\text{ mm H}_2\text{O}. Because mercury is 13.613.6 times denser than water, a column of water exerts 13.613.6 times less hydrostatic pressure than an equal height of mercury. You need to divide the water height by 13.613.6 to obtain pressure in torr\text{torr}.

  2. Step 2

    Threshold=0.0050×754.0 torr=3.77 torr  ⟹  68.0 torr>3.77 torr\text{Threshold} = 0.0050 \times 754.0\text{ torr} = 3.77\text{ torr} \implies 68.0\text{ torr} > 3.77\text{ torr}, so the correction exceeds the 0.50%0.50\% threshold.

    Correct

    Threshold=0.0050×754.0 torr=3.77 torr  ⟹  5.00 torr>3.77 torr\text{Threshold} = 0.0050 \times 754.0\text{ torr} = 3.77\text{ torr} \implies 5.00\text{ torr} > 3.77\text{ torr} (or 5.00754.0×100%≈0.663%>0.50%\frac{5.00}{754.0} \times 100\% \approx 0.663\% > 0.50\%) so the correction exceeds the threshold.

    Your threshold comparison logic is sound and reaches the correct qualitative conclusion, but it relies on your uncorrected hydrostatic pressure of 68.0 torr68.0\text{ torr} instead of 5.00 torr5.00\text{ torr}.

  3. Step 3

    Ptotal=754.0 torr−68.0 torr=686.0 torrP_{\text{total}} = 754.0\text{ torr} - 68.0\text{ torr} = 686.0\text{ torr}

    Correct

    Ptotal, inside=754.0 torr−5.00 torr=749.0 torrP_{\text{total, inside}} = 754.0\text{ torr} - 5.00\text{ torr} = 749.0\text{ torr}

    You correctly subtracted the hydrostatic head pressure because the liquid level inside the buret is higher than outside. However, using the unadjusted 68.0 torr68.0\text{ torr} propagated into an incorrect total pressure.

  4. Step 4

    PH2=686.0 torr−23.76 torr=662.24 torrP_{\text{H}_2} = 686.0\text{ torr} - 23.76\text{ torr} = 662.24\text{ torr}

    Correct

    PH2=749.0 torr−23.76 torr=725.2 torrP_{\text{H}_2} = 749.0\text{ torr} - 23.76\text{ torr} = 725.2\text{ torr}

    You correctly applied Dalton's law by subtracting the water vapor pressure from the total gas pressure, but your result inherits the earlier numerical error from Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the 0.50%0.50\% barometric threshold value as 3.77 torr3.77\text{ torr}.

You correctly identified that a raised liquid column inside the buret exerts a downward head that must be subtracted from the barometric pressure.

You applied Dalton's law of partial pressures accurately to account for water vapor pressure.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Density Ratio Omission in Manometer Height Conversion

You equated mm H2O\text{mm H}_2\text{O} directly to mm Hg\text{mm Hg} (torr\text{torr}) without converting via the density ratio ρH2OρHg\frac{\rho_{\text{H}_2\text{O}}}{\rho_{\text{Hg}}}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Overlooking that pressure units expressed as column heights (like torr=mm Hg\text{torr} = \text{mm Hg}) implicitly depend on the liquid's density (ρgh\rho g h). A millimeter of water does not exert the same pressure as a millimeter of mercury.

REASONING PATH
Your ACEpath teacher’s suggested approach
Fluid Density Equivalence
  • Equal hydrostatic pressure means P=ρ1gh1=ρ2gh2P = \rho_1 g h_1 = \rho_2 g h_2, which simplifies to hHg=hfluid×ρfluidρHgh_{\text{Hg}} = h_{\text{fluid}} \times \frac{\rho_{\text{fluid}}}{\rho_{\text{Hg}}}.

  • Whenever gas collection liquid is not mercury, convert column height to mm Hg\text{mm Hg} by dividing by 13.613.6 before adding or subtracting it from pressures given in torr\text{torr}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert water column height to equivalent mercury height: hHg=68.0 mm×1.00 g/cm313.6 g/cm3=5.00 mm Hg=5.00 torrh_{\text{Hg}} = 68.0\text{ mm} \times \frac{1.00\text{ g/cm}^3}{13.6\text{ g/cm}^3} = 5.00\text{ mm Hg} = 5.00\text{ torr}.

  2. Verify the threshold: 5.00 torr754.0 torr×100%=0.663%>0.50%\frac{5.00\text{ torr}}{754.0\text{ torr}} \times 100\% = 0.663\% > 0.50\%, confirming the correction must be included.

  3. Calculate the total gas pressure inside the buret: Ptotal, inside=Pbar−Phead=754.0 torr−5.00 torr=749.0 torrP_{\text{total, inside}} = P_{\text{bar}} - P_{\text{head}} = 754.0\text{ torr} - 5.00\text{ torr} = 749.0\text{ torr}.

  4. Apply Dalton's law for dry hydrogen gas: PH2=Ptotal, inside−PH2O=749.0 torr−23.76 torr=725.24 torr≈725.2 torrP_{\text{H}_2} = P_{\text{total, inside}} - P_{\text{H}_2\text{O}} = 749.0\text{ torr} - 23.76\text{ torr} = 725.24\text{ torr} \approx 725.2\text{ torr}.

Final answer

Hydrostatic correction=5.00 torr\text{Hydrostatic correction} = 5.00\text{ torr} (0.663%0.663\%, exceeding the threshold); PH2=725.2 torrP_{\text{H}_2} = 725.2\text{ torr}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice converting manometric column heights between different fluids using h1ρ1=h2ρ2h_1 \rho_1 = h_2 \rho_2.

  • Always write out the physical units completely (e.g., mm H2O\text{mm H}_2\text{O} vs. mm Hg\text{mm Hg}) to prevent treating length as equivalent to pressure.

OverviewACEpath Teacher's Diagnosis

03 The student ignores the hydrostatic head entirely when finding the partial pressure of hydrogen, assuming total gas pressure simply equals barometric pressure.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    hHg=68.0 mm13.6=5.00 torrh_{\text{Hg}} = \frac{68.0\text{ mm}}{13.6} = 5.00\text{ torr}

  2. Step 2

    Threshold=0.0050×754.0 torr=3.77 torr  ⟹  5.00 torr>3.77 torr\text{Threshold} = 0.0050 \times 754.0\text{ torr} = 3.77\text{ torr} \implies 5.00\text{ torr} > 3.77\text{ torr}, so the correction exceeds the 0.50%0.50\% threshold.

  3. Step 3

    Ptotal=Patm=754.0 torrP_{\text{total}} = P_{\text{atm}} = 754.0\text{ torr}

    Correct

    Ptotal, inside=Pbar−Phead=754.0 torr−5.00 torr=749.0 torrP_{\text{total, inside}} = P_{\text{bar}} - P_{\text{head}} = 754.0\text{ torr} - 5.00\text{ torr} = 749.0\text{ torr}

    Because the liquid level inside the buret is higher than outside, the raised column exerts downward hydrostatic pressure. At the reservoir surface level, Pbar=Ptotal, inside+PheadP_{\text{bar}} = P_{\text{total, inside}} + P_{\text{head}}, so you must subtract PheadP_{\text{head}} from PbarP_{\text{bar}} to find the total gas pressure inside the buret.

  4. Step 4

    PH2=754.0 torr−23.76 torr=730.24 torrP_{\text{H}_2} = 754.0\text{ torr} - 23.76\text{ torr} = 730.24\text{ torr}

    Correct

    PH2=749.0 torr−23.76 torr=725.24 torr≈725.2 torrP_{\text{H}_2} = 749.0\text{ torr} - 23.76\text{ torr} = 725.24\text{ torr} \approx 725.2\text{ torr}

    You applied Dalton's law of partial pressures with the correct subtraction of water vapor pressure, but your result was shifted by the uncorrected total pressure from Step 3.

WHAT YOU DID WELL
Compliments from Your Teacher

You accurately converted the water column height into equivalent torr using the ratio of densities.

You correctly compared the hydrostatic pressure against the 0.50%0.50\% threshold.

You correctly identified that water vapor pressure must be subtracted from total gas pressure to find the dry gas pressure.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of Hydrostatic Head in Total Gas Pressure

You confirmed that the hydrostatic head was significant, but then equated PtotalP_{\text{total}} directly to PatmP_{\text{atm}} as if the water levels were aligned.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the threshold check as an isolated calculation rather than incorporating the non-negligible hydrostatic head (PheadP_{\text{head}}) into the mechanical pressure balance (Pbar=Pgas+PheadP_{\text{bar}} = P_{\text{gas}} + P_{\text{head}}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Establish the Pressure Balance at Equal Liquid Levels
  • When liquid levels inside and outside are unequal, balance pressures at the lower meniscus surface: Poutside=Pinside+PcolumnP_{\text{outside}} = P_{\text{inside}} + P_{\text{column}} if the inside level is higher.

  • Always draw a horizontal reference line at the outer liquid surface to identify whether PheadP_{\text{head}} adds to or subtracts from barometric pressure.

Link Diagnostic Checks to the Main Calculation
  • If a correction passes a significance test, it must be carried into subsequent thermodynamic and partial-pressure equations.

  • Check that any evaluated correction term (Phead=5.00 torrP_{\text{head}} = 5.00\text{ torr}) appears in your expression for Ptotal, insideP_{\text{total, inside}} before applying Dalton's law.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Set up the mechanical pressure equilibrium at the level of the external water surface: Pbar=Ptotal, inside+PheadP_{\text{bar}} = P_{\text{total, inside}} + P_{\text{head}}.

  2. Solve for total trapped gas pressure: Ptotal, inside=754.0 torr−5.00 torr=749.0 torrP_{\text{total, inside}} = 754.0\text{ torr} - 5.00\text{ torr} = 749.0\text{ torr}.

  3. Apply Dalton's law of partial pressures: PH2=Ptotal, inside−PH2O=749.0 torr−23.76 torr=725.24 torrP_{\text{H}_2} = P_{\text{total, inside}} - P_{\text{H}_2\text{O}} = 749.0\text{ torr} - 23.76\text{ torr} = 725.24\text{ torr}.

Final answer

Hydrostatic correction =5.00 torr= 5.00\text{ torr} (exceeds 0.50%0.50\% threshold); PH2=725.2 torrP_{\text{H}_2} = 725.2\text{ torr}

NEXT STEPS
Final Takeaways from Your Teacher
  • Sketch the gas collection apparatus and indicate all pressure vectors acting on the water column.

  • Practice setting up hydrostatic pressure balance equations for cases where the inside liquid is both higher and lower than the reservoir level.

  • Solve problems where gas is collected over liquids of different densities (e.g., oil or dilute acid) to reinforce density conversion factors.

Lock it in

Similar question

01

Oxygen gas is collected over water at 20.0∘C20.0^\circ\text{C} (PH2O=17.5 torrP_{\text{H}_2\text{O}} = 17.5\text{ torr}) when atmospheric pressure is 762.0 torr762.0\text{ torr}. The water level inside the eudiometer is 10.2 cm10.2\text{ cm} higher than the outside reservoir. Given ρwater=1.00 g/cm3\rho_{\text{water}} = 1.00\text{ g/cm}^3 and ρHg=13.6 g/cm3\rho_{\text{Hg}} = 13.6\text{ g/cm}^3, calculate the partial pressure of dry O2\text{O}_2.

Answer

737.0 torr737.0\text{ torr}. Convert water height: Phead=102 mm/13.6=7.50 torrP_{\text{head}} = 102\text{ mm} / 13.6 = 7.50\text{ torr}. Total pressure inside: Ptotal=762.0−7.50=754.5 torrP_{\text{total}} = 762.0 - 7.50 = 754.5\text{ torr}. Dry oxygen pressure: PO2=754.5−17.5=737.0 torrP_{\text{O}_2} = 754.5 - 17.5 = 737.0\text{ torr}.

02

Nitrogen gas is collected over water in an inverted container at 22.0∘C22.0^\circ\text{C} (PH2O=19.8 torrP_{\text{H}_2\text{O}} = 19.8\text{ torr}). The atmospheric pressure is 748.5 torr748.5\text{ torr}. In this setup, the water level inside the container is accidentally pushed 4.08 cm4.08\text{ cm} LOWER than the exterior water surface. Calculate the partial pressure of dry N2\text{N}_2 in torr\text{torr}.

Answer

731.7 torr731.7\text{ torr}. Convert water column: Phead=40.8 mm/13.6=3.00 torrP_{\text{head}} = 40.8\text{ mm} / 13.6 = 3.00\text{ torr}. Because the inside water level is lower than outside, exterior hydrostatic pressure compresses the gas: Ptotal=Patm+Phead=748.5+3.00=751.5 torrP_{\text{total}} = P_{\text{atm}} + P_{\text{head}} = 748.5 + 3.00 = 751.5\text{ torr}. Dry gas pressure: PN2=751.5−19.8=731.7 torrP_{\text{N}_2} = 751.5 - 19.8 = 731.7\text{ torr}.

03

Methane gas is collected over an unknown nonvolatile organic liquid (density =0.850 g/cm3= 0.850\text{ g/cm}^3) at an atmospheric pressure of 750.0 torr750.0\text{ torr}. The liquid level inside the collection tube is 24.0 cm24.0\text{ cm} higher than the open beaker surface. The vapor pressure of the organic liquid at this temperature is 12.4 torr12.4\text{ torr}. Calculate the partial pressure of methane gas.

Answer

722.6 torr722.6\text{ torr}. Convert liquid height to equivalent mm Hg\text{mm Hg}: Phead=240 mm×(0.850/13.6)=15.0 torrP_{\text{head}} = 240\text{ mm} \times (0.850 / 13.6) = 15.0\text{ torr}. Since internal liquid is higher: Ptotal=750.0−15.0=735.0 torrP_{\text{total}} = 750.0 - 15.0 = 735.0\text{ torr}. Methane partial pressure: PCH4=735.0−12.4=722.6 torrP_{\text{CH}_4} = 735.0 - 12.4 = 722.6\text{ torr}.

Loading workspace…