A low-pressure chemical vapor deposition chamber operates under high vacuum at an ultimate limiting pressure of P=1.333×10−7 mbarP = 1.333 \times 10^{-7}\text{ mbar}. (a) Convert this asymptotic limit pressure to the coherent SI derived unit of pascals (Pa\text{Pa}), given 1 bar=1.000×105 Pa1\text{ bar} = 1.000 \times 10^5\text{ Pa}. (b) Using the ideal gas law in the molecular limit (P=nVkBTP = n_V k_B T, where kB=1.381×10−23 J/Kk_B = 1.381 \times 10^{-23}\text{ J}/\text{K}), calculate the molecular number density nVn_V (molecules per cubic meter, m−3\text{m}^{-3}) at T=298.15 KT = 298.15\text{ K}. Express both values in standard scientific notation with four significant figures.

Answer and steps

Final answer

(a) 1.333×10−5 Pa1.333 \times 10^{-5}\text{ Pa}; (b) 3.238×1015 molecules/m33.238 \times 10^{15}\text{ molecules}/\text{m}^3

Steps

Part (a): Pressure Conversion to Pascals (Pa\text{Pa})

  1. Relate millibars (mbar\text{mbar}) to the coherent SI unit pascals (Pa\text{Pa}): The metric prefix milli- represents a factor of 10−310^{-3}. Therefore: 1 mbar=10−3 bar1\text{ mbar} = 10^{-3}\text{ bar} Given that 1 bar=1.000×105 Pa1\text{ bar} = 1.000 \times 10^5\text{ Pa}: 1 mbar=10−3×1.000×105 Pa=100 Pa=1.000×102 Pa1\text{ mbar} = 10^{-3} \times 1.000 \times 10^5\text{ Pa} = 100\text{ Pa} = 1.000 \times 10^2\text{ Pa}
  2. Convert the given chamber pressure: P=1.333×10−7 mbar×1.000×102 Pa1 mbar=1.333×10−5 PaP = 1.333 \times 10^{-7}\text{ mbar} \times \frac{1.000 \times 10^2\text{ Pa}}{1\text{ mbar}} = 1.333 \times 10^{-5}\text{ Pa}

Part (b): Molecular Number Density (nVn_V)

  1. State the governing equation: The ideal gas law written in terms of molecular number density is: P=nVkBTP = n_V k_B T Rearranging to solve for the number density nVn_V: nV=PkBTn_V = \frac{P}{k_B T}
  2. Substitute the known quantities in coherent SI units:

    • Pressure: P=1.333×10−5 Pa=1.333×10−5 N⋅m−2P = 1.333 \times 10^{-5}\text{ Pa} = 1.333 \times 10^{-5}\text{ N}\cdot\text{m}^{-2}
    • Boltzmann constant: kB=1.381×10−23 J⋅K−1k_B = 1.381 \times 10^{-23}\text{ J}\cdot\text{K}^{-1}
    • Absolute temperature: T=298.15 KT = 298.15\text{ K}

    First, calculate the thermal energy product kBTk_B T: kBT=(1.381×10−23 J⋅K−1)(298.15 K)≈4.1175×10−21 Jk_B T = (1.381 \times 10^{-23}\text{ J}\cdot\text{K}^{-1})(298.15\text{ K}) \approx 4.1175 \times 10^{-21}\text{ J}

    Now, calculate nVn_V: nV=1.333×10−5 Pa4.1175×10−21 J≈3.2374×1015 m−3n_V = \frac{1.333 \times 10^{-5}\text{ Pa}}{4.1175 \times 10^{-21}\text{ J}} \approx 3.2374 \times 10^{15}\text{ m}^{-3}

  3. Round to four significant figures: nV=3.238×1015 molecules/m3n_V = 3.238 \times 10^{15}\text{ molecules}/\text{m}^3

Pitfall to avoid: Ensure pressure is converted to the SI unit (Pa\text{Pa}, where 1 Pa=1 J/m31\text{ Pa} = 1\text{ J}/\text{m}^3) before calculating number density. Using pressure directly in mbar\text{mbar} or bar\text{bar} without conversion introduces dimensional errors of several orders of magnitude.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student misinterprets the milli- prefix as 10³ instead of 10⁻³, multiplying by 1000 instead of dividing when converting mbar to bar.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    1 mbar=103 bar  ⟹  P=1.333×10−7×103×105 Pa=1.333×101 Pa1\text{ mbar} = 10^3\text{ bar} \implies P = 1.333 \times 10^{-7} \times 10^3 \times 10^5\text{ Pa} = 1.333 \times 10^1\text{ Pa}

    Correct

    1 mbar=10−3 bar  ⟹  P=1.333×10−7 mbar×102 Pa/mbar=1.333×10−5 Pa1\text{ mbar} = 10^{-3}\text{ bar} \implies P = 1.333 \times 10^{-7}\text{ mbar} \times 10^2\text{ Pa/mbar} = 1.333 \times 10^{-5}\text{ Pa}

    You treated the prefix milli- (m\text{m}) as a multiplier of 10310^3 rather than 10−310^{-3}. A millibar is one-thousandth of a bar, so 1 mbar=10−3 bar=100 Pa1\text{ mbar} = 10^{-3}\text{ bar} = 100\text{ Pa}, which leads to P=1.333×10−5 PaP = 1.333 \times 10^{-5}\text{ Pa}.

  2. Step 2

    nV=PkBT=1.333×1011.381×10−23×298.15=3.238×1021 m−3n_V = \frac{P}{k_B T} = \frac{1.333 \times 10^1}{1.381 \times 10^{-23} \times 298.15} = 3.238 \times 10^{21}\text{ m}^{-3}

    Correct

    nV=PkBT=1.333×10−5 Pa(1.381×10−23 J/K)(298.15 K)=3.238×1015 m−3n_V = \frac{P}{k_B T} = \frac{1.333 \times 10^{-5}\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(298.15\text{ K})} = 3.238 \times 10^{15}\text{ m}^{-3}

    You correctly rearranged the molecular ideal gas law and accurately performed the division with four significant figures, but your result was scaled up by 10610^6 due to substituting your pressure from part (a).

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly recalled the relationship between bar and pascal (1 bar=105 Pa1\text{ bar} = 10^5\text{ Pa}).

You correctly rearranged the molecular form of the ideal gas law to solve for nV=PkBTn_V = \frac{P}{k_B T}.

You maintained four significant figures and correct SI units in your final calculation.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Metric prefix inversion (milli- as 10³ instead of 10⁻³)

No, this is a conceptual mix-up between positive (kilo-) and negative (milli-) metric prefixes.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the submultiple prefix milli- (10−310^{-3}) with the multiple prefix kilo- (10310^3). Because 1 mbar1\text{ mbar} is smaller than 1 bar1\text{ bar}, converting to bars requires multiplying by 10−310^{-3} (or dividing by 10001000), not multiplying by 10310^3.

REASONING PATH
Your ACEpath teacher’s suggested approach
SI Prefix Magnitude Check
  • Prefixes representing fractions of a base unit have negative powers of ten: milli- is 10−310^{-3}, micro- is 10−610^{-6}, and nano- is 10−910^{-9}.

  • Always verify whether the prefixed unit is smaller or larger than the base unit before writing the conversion factor.

Physical Vacuum Sanity Check
  • High vacuum environments have pressures far below atmospheric pressure (1 atm≈1.013×105 Pa1\text{ atm} \approx 1.013 \times 10^5\text{ Pa}).

  • Compare your converted pressure to ambient conditions: an ultra-high vacuum pressure should be a very small fraction of a pascal, not tens of pascals.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Express 1 mbar1\text{ mbar} in pascals using 10−310^{-3}: 1 mbar=10−3 bar=10−3×105 Pa=1.000×102 Pa1\text{ mbar} = 10^{-3}\text{ bar} = 10^{-3} \times 10^5\text{ Pa} = 1.000 \times 10^2\text{ Pa}.

  2. Convert the chamber pressure: P=(1.333×10−7 mbar)(1.000×102 Pa/mbar)=1.333×10−5 PaP = (1.333 \times 10^{-7}\text{ mbar})(1.000 \times 10^2\text{ Pa/mbar}) = 1.333 \times 10^{-5}\text{ Pa}.

  3. Substitute the correct pressure into the number density equation: nV=1.333×10−5 Pa(1.381×10−23 J/K)(298.15 K)n_V = \frac{1.333 \times 10^{-5}\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(298.15\text{ K})}.

  4. Evaluate: nV=1.333×10−54.11745×10−21=3.23744×1015≈3.238×1015 m−3n_V = \frac{1.333 \times 10^{-5}}{4.11745 \times 10^{-21}} = 3.23744 \times 10^{15} \approx 3.238 \times 10^{15}\text{ m}^{-3}.

Final answer

(a) 1.333×10−5 Pa1.333 \times 10^{-5}\text{ Pa}; (b) 3.238×1015 m−33.238 \times 10^{15}\text{ m}^{-3}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the standard table of SI prefixes, paying special attention to signs on exponents (10−310^{-3} vs. 10310^3).

  • Practice setting up unit conversions using dimensional analysis fractions so that units explicitly cancel out.

OverviewACEpath Teacher's Diagnosis

02 The student equates 1 mbar directly to 1 bar, completely omitting the milli- metric conversion factor when converting to pascals.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    P=1.333×10−7×1.000×105 Pa  ⟹  P=1.333×10−2 PaP = 1.333 \times 10^{-7} \times 1.000 \times 10^5\text{ Pa} \implies P = 1.333 \times 10^{-2}\text{ Pa}

    Correct

    P=1.333×10−7 mbar×10−3 bar1 mbar×1.000×105 Pa1 bar=1.333×10−5 PaP = 1.333 \times 10^{-7}\text{ mbar} \times \frac{10^{-3}\text{ bar}}{1\text{ mbar}} \times \frac{1.000 \times 10^5\text{ Pa}}{1\text{ bar}} = 1.333 \times 10^{-5}\text{ Pa}

    You multiplied the pressure in millibars directly by the conversion factor for bars (105 Pa/bar10^5\text{ Pa/bar}), omitting the factor of 10−310^{-3} for the prefix milli-\text{milli-} (1 mbar=10−3 bar=100 Pa1\text{ mbar} = 10^{-3}\text{ bar} = 100\text{ Pa}).

  2. Step 2

    nV=P/(kBT)  ⟹  nV=1.333×10−2/(1.381×10−23×298.15)  ⟹  nV=3.238×1018 m−3n_V = P / (k_B T) \implies n_V = 1.333 \times 10^{-2} / (1.381 \times 10^{-23} \times 298.15) \implies n_V = 3.238 \times 10^{18}\text{ m}^{-3}

    Correct

    nV=PkBT=1.333×10−5 Pa(1.381×10−23 J/K)(298.15 K)=3.238×1015 molecules/m3n_V = \frac{P}{k_B T} = \frac{1.333 \times 10^{-5}\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(298.15\text{ K})} = 3.238 \times 10^{15}\text{ molecules/m}^3

    You correctly rearranged the molecular ideal gas law and computed the quotient with proper significant figures, but the resulting numerical value was scaled by 10310^3 due to the pressure error from part (a).

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly rearranged the molecular ideal gas law to solve for molecular number density nV=PkBTn_V = \frac{P}{k_B T}.

You carried out the scientific notation division and rounded accurately to four significant figures.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omitted Metric Prefix

You treated 1 mbar1\text{ mbar} as 1 bar1\text{ bar} rather than 10−3 bar10^{-3}\text{ bar} when applying the conversion factor to pascals.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You skipped decomposing compound non-SI units into their base prefix and core unit before multiplying by a secondary conversion factor.

REASONING PATH
Your ACEpath teacher’s suggested approach
Decompose Metric Prefixes First
  • Separate any metric prefix from the base or named unit: 1 mbar=10−3 bar1\text{ mbar} = 10^{-3}\text{ bar}.

  • Always write out the two-step dimensional analysis chain: mbar→bar→Pa\text{mbar} \to \text{bar} \to \text{Pa}.

Verify Reasonable Magnitude
  • 1 bar=105 Pa1\text{ bar} = 10^5\text{ Pa}, so 1 mbar1\text{ mbar} must be much smaller: exactly 100 Pa100\text{ Pa} (102 Pa10^2\text{ Pa}).

  • Multiply values in mbar\text{mbar} by 10210^2, not 10510^5, to convert directly to Pa\text{Pa}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. P=1.333×10−7 mbar×(102 Pa/mbar)=1.333×10−5 PaP = 1.333 \times 10^{-7}\text{ mbar} \times (10^2\text{ Pa}/\text{mbar}) = 1.333 \times 10^{-5}\text{ Pa}

  2. nV=1.333×10−5 Pa(1.381×10−23 J/K)(298.15 K)n_V = \frac{1.333 \times 10^{-5}\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(298.15\text{ K})}

  3. nV=1.333×10−54.11745×10−21 m−3=3.2374×1015 m−3n_V = \frac{1.333 \times 10^{-5}}{4.11745 \times 10^{-21}}\text{ m}^{-3} = 3.2374 \times 10^{15}\text{ m}^{-3}

Final answer

(a) 1.333×10−5 Pa1.333 \times 10^{-5}\text{ Pa}; (b) 3.238×1015 molecules/m33.238 \times 10^{15}\text{ molecules/m}^3

NEXT STEPS
Final Takeaways from Your Teacher
  • Write down explicit conversion factors with units cancelling on paper whenever dealing with prefixed units like mbar\text{mbar}, kPa\text{kPa}, or nm\text{nm}.

  • Before proceeding to downstream equations, sanity-check the exponent: converting from a smaller unit (mbar\text{mbar}) to a larger unit (bar\text{bar}) must decrease the power of 10 by 3.

OverviewACEpath Teacher's Diagnosis

03 The student erroneously multiplies pressure by temperature rather than dividing by it when isolating the number density n_V.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    1 mbar=100 Pa  ⟹  P=1.333×10−7×100 Pa=1.333×10−5 Pa1\text{ mbar} = 100\text{ Pa} \implies P = 1.333 \times 10^{-7} \times 100\text{ Pa} = 1.333 \times 10^{-5}\text{ Pa}

  2. Step 2

    nV=P×TkBn_V = \frac{P \times T}{k_B}

    Correct

    nV=PkBTn_V = \frac{P}{k_B T}

    Starting from P=nVkBTP = n_V k_B T, both kBk_B and TT multiply nVn_V. To isolate nVn_V, you must divide both sides by the entire product kBTk_B T, which places both kBk_B and TT in the denominator.

  3. Step 3

    nV=1.333×10−5×298.151.381×10−23  ⟹  nV=2.878×1021 m−3n_V = \frac{1.333 \times 10^{-5} \times 298.15}{1.381 \times 10^{-23}} \implies n_V = 2.878 \times 10^{21}\text{ m}^{-3}

    Correct

    nV=1.333×10−5 Pa(1.381×10−23 J/K)(298.15 K)=3.238×1015 m−3n_V = \frac{1.333 \times 10^{-5}\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(298.15\text{ K})} = 3.238 \times 10^{15}\text{ m}^{-3}

    Your numerical computation was executed accurately according to your rearranged formula, but the result is incorrect due to the inverted placement of temperature in Step 2.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly related millibars to pascals using 1 mbar=100 Pa1\text{ mbar} = 100\text{ Pa}.

You properly maintained standard scientific notation and four significant figures throughout your work.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Algebraic rearrangement error

You multiplied by temperature TT rather than dividing by it when isolating the unknown variable.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

When isolating a factor from a product of three terms (A=x⋅y⋅zA = x \cdot y \cdot z), dividing by the unwanted factors requires moving all remaining multiplying factors into the denominator (x=Ay⋅zx = \frac{A}{y \cdot z}). Treating one multiplying factor as a divisor and the other as a multiplier led to dimensional inconsistency.

REASONING PATH
Your ACEpath teacher’s suggested approach
Isolating Factors in a Product
  • For any equation of the form P=nV⋅(kBT)P = n_V \cdot (k_B T), isolating nVn_V requires dividing both sides by the multiplier: nV=PkBTn_V = \frac{P}{k_B T}.

  • Always circle the target variable and divide both sides by everything multiplying it before substituting numbers.

Dimensional Consistency Check
  • The units of PkBT\frac{P}{k_B T} are J/m3J=m−3\frac{\text{J}/\text{m}^3}{\text{J}} = \text{m}^{-3}, whereas PTkB\frac{P T}{k_B} gives units of K2/m3\text{K}^2/\text{m}^3.

  • Perform a quick unit check on your rearranged algebraic expression to verify that temperature cancels out.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Divide both sides of P=nVkBTP = n_V k_B T by kBTk_B T: nV=PkBTn_V = \frac{P}{k_B T}.

  2. Substitute the SI values: nV=1.333×10−5 Pa(1.381×10−23 J/K)(298.15 K)n_V = \frac{1.333 \times 10^{-5}\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(298.15\text{ K})}.

  3. Evaluate the denominator: kBT=(1.381×10−23)(298.15)=4.11745×10−21 Jk_B T = (1.381 \times 10^{-23})(298.15) = 4.11745 \times 10^{-21}\text{ J}.

  4. Compute the quotient: nV=1.333×10−54.11745×10−21≈3.2375×1015 m−3n_V = \frac{1.333 \times 10^{-5}}{4.11745 \times 10^{-21}} \approx 3.2375 \times 10^{15}\text{ m}^{-3}.

Final answer

(a) 1.333×10−5 Pa1.333 \times 10^{-5}\text{ Pa}; (b) 3.238×1015 molecules/m33.238 \times 10^{15}\text{ molecules/m}^3

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice isolating variables from multi-factor products by writing out the division step explicitly.

  • Verify the physical sense of the answer: in a high-vacuum chamber, molecular density should decrease at higher temperature for a given pressure, meaning TT must reside in the denominator.

Lock it in

Similar question

01

A vacuum chamber has a base pressure of 4.50×10−6 mbar4.50 \times 10^{-6}\text{ mbar}. Convert this pressure to pascals (Pa\text{Pa}), given 1 bar=1.00×105 Pa1\text{ bar} = 1.00 \times 10^5\text{ Pa}. Express your answer in standard scientific notation with three significant figures.

Answer

4.50×10−4 Pa4.50 \times 10^{-4}\text{ Pa}. Key steps: 1 mbar=10−3 bar=102 Pa1\text{ mbar} = 10^{-3}\text{ bar} = 10^2\text{ Pa}. P=(4.50×10−6 mbar)(102 Pa/mbar)=4.50×10−4 PaP = (4.50 \times 10^{-6}\text{ mbar})(10^2\text{ Pa/mbar}) = 4.50 \times 10^{-4}\text{ Pa}.

02

An ionization gauge registers a pressure of 8.28×10−8 Pa8.28 \times 10^{-8}\text{ Pa}. At T=300.0 KT = 300.0\text{ K}, calculate the molecular number density nVn_V using P=nVkBTP = n_V k_B T, where kB=1.381×10−23 J/Kk_B = 1.381 \times 10^{-23}\text{ J/K}. Express your answer with three significant figures.

Answer

2.00×1013 molecules/m32.00 \times 10^{13}\text{ molecules/m}^3. Key steps: nV=PkBT=8.28×10−8 Pa(1.381×10−23 J/K)(300.0 K)=8.28×10−84.143×10−21=1.9985×1013≈2.00×1013 m−3n_V = \frac{P}{k_B T} = \frac{8.28 \times 10^{-8}\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(300.0\text{ K})} = \frac{8.28 \times 10^{-8}}{4.143 \times 10^{-21}} = 1.9985 \times 10^{13} \approx 2.00 \times 10^{13}\text{ m}^{-3}.

03

In a semiconductor sputtering system, argon gas is maintained at 2.00×10−3 mbar2.00 \times 10^{-3}\text{ mbar} and T=350.0 KT = 350.0\text{ K}. (a) Convert the pressure to Pa\text{Pa}. (b) Determine the number of argon atoms contained in a chamber volume of V=0.250 m3V = 0.250\text{ m}^3 using P=nVkBTP = n_V k_B T (kB=1.381×10−23 J/Kk_B = 1.381 \times 10^{-23}\text{ J/K}).

Answer

(a) 2.00×10−1 Pa2.00 \times 10^{-1}\text{ Pa}; (b) 1.04×1019 atoms1.04 \times 10^{19}\text{ atoms}. Key steps: (a) P=(2.00×10−3 mbar)(102 Pa/mbar)=0.200 Pa=2.00×10−1 PaP = (2.00 \times 10^{-3}\text{ mbar})(10^2\text{ Pa/mbar}) = 0.200\text{ Pa} = 2.00 \times 10^{-1}\text{ Pa}. (b) nV=0.200 Pa(1.381×10−23 J/K)(350.0 K)=4.138×1019 m−3n_V = \frac{0.200\text{ Pa}}{(1.381 \times 10^{-23}\text{ J/K})(350.0\text{ K})} = 4.138 \times 10^{19}\text{ m}^{-3}. Total atoms N=nV⋅V=(4.138×1019 m−3)(0.250 m3)=1.035×1019≈1.04×1019 atomsN = n_V \cdot V = (4.138 \times 10^{19}\text{ m}^{-3})(0.250\text{ m}^3) = 1.035 \times 10^{19} \approx 1.04 \times 10^{19}\text{ atoms}.