Resources
A manufacturing facility plans to abate its acidic flue gas emissions by coupling a limestone scrubbing process with downstream gypsum recovery, reducing raw material usage. The scrubbing reaction is . A combustion flue stream enters the scrubber at and with a volumetric flow rate of and an concentration of by volume. (a) Assuming ideal gas behavior, calculate the mass of pure (molar mass ) consumed per hour to achieve capture efficiency of . (b) Calculate the mass of dry gypsum (, molar mass ) produced per day.
Answer and steps
Final answer
(a) Mass of ; (b) Mass of gypsum produced
Steps
Determine the total flue gas and flow rates
Calculate the total volumetric flow rate of flue gas on an hourly basis:
Using the given concentration of by volume ():
Calculate the molar flow rate of entering the scrubber
Apply the ideal gas law, , to find the entering molar flow rate of :
Substituting , , and the ideal gas constant :
Calculate the mass of consumed per hour (Part a)
With a capture efficiency of (), the molar rate of scrubbed from the flue stream is:
From the balanced chemical equation:
The stoichiometric ratio between and is :
Multiply by the molar mass of ():
Common Pitfall: Always account for the capture efficiency (). Calculating reactant consumption assuming capture leads to an overestimate of required pure limestone and downstream gypsum yield.
Calculate the mass of dry gypsum produced per day (Part b)
The stoichiometry shows a molar ratio between reacted and dry gypsum ():
Using the molar mass of gypsum (), calculate the mass produced per hour:
Over a full operating day:
Typical errors
01 The student ignores the 96.00% capture efficiency, assuming 100% of the entering SO₂ reacts with CaCO₃ and converts to gypsum.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3
- Step 4Correct
You assumed that of the entering reacts with . Because the capture efficiency is , only of the inlet is scrubbed and consumes limestone.
- Step 5Correct
Your conversion from hourly rate to daily yield and your molar mass multiplication were executed properly, but the result is overstated because it inherited the uncorrected capture assumption from Step 4.
WHAT YOU DID WELL
Compliments from Your TeacherYou converted volumetric flow rates to consistent hourly time units.
You used the ideal gas law with appropriate constants and temperatures to compute molar flow rates.
You applied the correct molar masses for both calcium carbonate and gypsum.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou used the total entering rate of directly in stoichiometric calculations without multiplying by the removal fraction.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing inlet pollutant flow with reacted pollutant flow. In industrial scrubbing and abatement systems, chemical reactions consume reactants and yield products based strictly on the captured or converted portion, , rather than the total entering stream.
REASONING PATH
Your ACEpath teacher’s suggested approach- Inlet vs. Reacted Stream
Only the captured fraction of a pollutant undergoes reaction in a scrubber: .
Always multiply the entering molar rate by the fractional capture efficiency before writing the stoichiometric mole ratios for reagent consumption or product yield.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate reacted : .
Apply stoichiometry to find consumption: (or without intermediate rounding).
Determine daily gypsum production from reacted moles: .
(a) (or ); (b)
02 The student uses the standard molar volume of 22.4 L/mol at STP instead of applying the ideal gas equation at 350.0 K.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You divided by the standard molar volume of , which is only valid at standard temperature and pressure ( and ). Because the flue gas enters at , you need to calculate moles using .
- Step 3Correct
Your method of multiplying the entering molar flow rate by capture efficiency and then by the molar mass of is completely correct, but the numeric value is affected by the earlier molar volume substitution.
- Step 4Correct
Your stoichiometric ratio, daily conversion factor (), and molar mass conversion for gypsum are all correct, but the final answer carries over the error from Step 2.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted the gas volumetric flow rate from minutes to hours and applied the concentration.
You correctly incorporated the capture efficiency into the reacted molar rate.
You used the correct stoichiometric ratios and molar masses for both and gypsum.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the STP constant instead of using the ideal gas equation with the actual flue gas temperature of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisTreating as a universal gas conversion factor rather than recognizing that molar volume depends directly on temperature ().
REASONING PATH
Your ACEpath teacher’s suggested approach- Temperature Condition Verification
The value is valid strictly at standard temperature and pressure (, ).
Check whether the operating temperature matches before using ; if , always use .
CORRECTED PATH
ACEpath Teacher's Demonstration(a) of ; (b) of dry gypsum
03 The student misinterprets parts per million by volume as parts per hundred, dividing 2500 by 100 instead of 10⁶.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Parts per million () represents parts per , so . Dividing by treats the concentration as percent and made your calculated flow times larger than the entire flue gas stream.
- Step 3Correct
Your application of the capture efficiency and the molar mass of was methodologically sound, but the result inherits the scaling error from Step 2.
- Step 4Correct
Your stoichiometric ratio, daily time conversion, and gypsum molar mass calculation were executed properly, but the numerical answer is scaled up by due to the earlier conversion mistake.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly used the ideal gas law to determine the molar flow rate of the entering gas stream.
You correctly factored in the capture efficiency before determining reactant requirements.
You accurately tracked the stoichiometric ratios to calculate the daily gypsum production.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou divided by instead of , accidentally treating parts per million as a percentage.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing parts per million (, base ) with percent (, base ), leading to a mole fraction greater than () rather than .
REASONING PATH
Your ACEpath teacher’s suggested approach- Define parts per million
in mole or volume fraction.
Whenever you see , write immediately beside the number.
- Sanity check on mole fractions
The mole fraction of any component in a mixture must satisfy .
Verify that your component molar flow rate is strictly less than the total molar flow rate .
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate the entering molar flow rate of : .
Determine the captured rate: .
Calculate the hourly mass: .
Calculate daily gypsum production: .
(a) of ; (b) of dry gypsum
Lock it in
How do you calculate the molar reaction rate of a pollutant in a scrubber with capture efficiency ?
. Only the captured portion reacts; the uncaptured fraction exits unreacted.
Similar question
A thermal plant emits flue gas at a rate of . A dry lime scrubber captures of the via the reaction . Calculate the mass of pure (molar mass ) consumed per hour.
Answer
Reacted . From stoichiometry, . Mass consumed .
An incinerator exhaust contains at and with an exhaust flow rate of . If the wet limestone scrubber operates at capture efficiency, calculate the daily production (in metric tons, ) of dry gypsum (, ).
Answer
Total gas flow . Molar flue gas rate . Inlet . Reacted . Daily gypsum .
A coal boiler flue stream carries into a limestone scrubber. To meet environmental regulations, exactly of pure gypsum (, ) is recovered. If the scrubber's measured capture efficiency is , what is the total molar flow rate of entering the scrubber in , and what mass of () escapes uncaptured into the atmosphere per hour?
Answer
Gypsum production rate . Since the reaction is , reacted . Entering . Uncaptured . Escaping mass .