Resources

A standard galvanic cell is constructed at 298 K298\text{ K} using a zinc electrode immersed in a 1.00 M Zn(NO3)21.00\text{ M }\text{Zn(NO}_3)_2 solution and a copper electrode immersed in a 1.00 M Cu(NO3)21.00\text{ M }\text{Cu(NO}_3)_2 solution, connected by a potassium nitrate salt bridge. Given the standard reduction potentials E∘=−0.763 VE^\circ = -0.763\text{ V} for Zn2+(aq)+2e−→Zn(s)\text{Zn}^{2+}(aq) + 2e^- \rightarrow \text{Zn}(s) and E∘=+0.342 VE^\circ = +0.342\text{ V} for Cu2+(aq)+2e−→Cu(s)\text{Cu}^{2+}(aq) + 2e^- \rightarrow \text{Cu}(s), write the overall balanced cell reaction and calculate the standard cell potential (Ecell∘E^\circ_{\text{cell}}).

Answer and steps

Final answer

Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s); Ecell∘=+1.105 VE^\circ_{\text{cell}} = +1.105\text{ V}

Steps

01

Identify the Cathode and Anode

In a galvanic cell, the reaction occurs spontaneously, requiring a positive standard cell potential (Ecell∘>0E^\circ_{\text{cell}} > 0).

Compare the standard reduction potentials (E∘E^\circ) of the two half-reactions:

  • CuX2+(aq)+2e−→Cu(s)E∘=+0.342 V\ce{Cu^{2+}}(aq) + 2e^- \rightarrow \ce{Cu}(s) \quad E^\circ = +0.342\text{ V}
  • ZnX2+(aq)+2e−→Zn(s)E∘=−0.763 V\ce{Zn^{2+}}(aq) + 2e^- \rightarrow \ce{Zn}(s) \quad E^\circ = -0.763\text{ V}

The species with the more positive (higher) reduction potential is more readily reduced, meaning it will serve as the cathode:

  • Cathode (reduction): CuX2+(aq)+2e−→Cu(s)\ce{Cu^{2+}}(aq) + 2e^- \rightarrow \ce{Cu}(s)

The species with the lower reduction potential will undergo oxidation at the anode:

  • Anode (oxidation): Zn(s)→ZnX2+(aq)+2e−\ce{Zn}(s) \rightarrow \ce{Zn^{2+}}(aq) + 2e^-

02

Write the Overall Balanced Cell Reaction

Combine the reduction half-reaction and the oxidation half-reaction. Because both half-reactions involve 22 electrons, the electrons cancel directly without needing multiplication:

Zn(s)+CuX2+(aq)→ZnX2+(aq)+Cu(s)\ce{Zn}(s) + \ce{Cu^{2+}}(aq) \rightarrow \ce{Zn^{2+}}(aq) + \ce{Cu}(s)


03

Calculate the Standard Cell Potential (Ecell∘E^\circ_{\text{cell}})

Use the standard cell potential formula:

Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}

Substitute the given standard reduction potentials:

Ecell∘=+0.342 V−(−0.763 V)E^\circ_{\text{cell}} = +0.342\text{ V} - (-0.763\text{ V}) Ecell∘=+0.342 V+0.763 V=+1.105 VE^\circ_{\text{cell}} = +0.342\text{ V} + 0.763\text{ V} = +1.105\text{ V}

Common Pitfall: When using the formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}, do not reverse the sign of the anode's standard reduction potential beforehand. The minus sign in the formula already accounts for reversing the reduction reaction into an oxidation reaction.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student subtracts the reduction potential of the cathode from the anode, obtaining a negative cell potential for a galvanic cell.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s)

  2. Step 2

    Ecell∘=Eanode∘−Ecathode∘  ⟹  Ecell∘=−0.763 V−(+0.342 V)E^\circ_{\text{cell}} = E^\circ_{\text{anode}} - E^\circ_{\text{cathode}} \implies E^\circ_{\text{cell}} = -0.763\text{ V} - (+0.342\text{ V})

    Correct

    Ecell∘=Ecathode∘−Eanode∘  ⟹  Ecell∘=+0.342 V−(−0.763 V)E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} \implies E^\circ_{\text{cell}} = +0.342\text{ V} - (-0.763\text{ V})

    You inverted the standard cell potential formula by subtracting the cathode potential from the anode potential rather than calculating Ecathode∘−Eanode∘E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

  3. Step 3

    Ecell∘=−1.105 VE^\circ_{\text{cell}} = -1.105\text{ V}

    Correct

    Ecell∘=+1.105 VE^\circ_{\text{cell}} = +1.105\text{ V}

    Your arithmetic follows correctly from your inverted formula, but because the formula was reversed, the resulting potential has an incorrect negative sign.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified which species is oxidized and which is reduced.

You correctly balanced the overall cell reaction.

You correctly identified the standard reduction potential values for both electrodes.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula Inversion

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You recalled the cell potential formula as anode minus cathode instead of cathode minus anode (Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}), overlooking the sanity check that standard galvanic cells must have a positive cell potential (Ecell∘>0E^\circ_{\text{cell}} > 0).

REASONING PATH
Your ACEpath teacher’s suggested approach
Cathode vs. Anode Formula
  • Standard cell potential using standard reduction potentials is defined as Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} (or Ered∘+Eox∘E^\circ_{\text{red}} + E^\circ_{\text{ox}}).

  • Always write Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} and verify that the cathode has the more positive reduction potential.

Galvanic Cell Sanity Check
  • Galvanic (voltaic) cells run spontaneously under standard conditions, which requires ΔG∘<0\Delta G^\circ < 0 and Ecell∘>0E^\circ_{\text{cell}} > 0.

  • If you compute a negative Ecell∘E^\circ_{\text{cell}} for a galvanic cell, immediately re-check your formula and electrode assignments.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Use the standard cell potential formula: Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}

  2. Substitute the cathode potential (+0.342 V+0.342\text{ V}) and anode potential (−0.763 V-0.763\text{ V}): Ecell∘=+0.342 V−(−0.763 V)E^\circ_{\text{cell}} = +0.342\text{ V} - (-0.763\text{ V})

  3. Evaluate: Ecell∘=+0.342 V+0.763 V=+1.105 VE^\circ_{\text{cell}} = +0.342\text{ V} + 0.763\text{ V} = +1.105\text{ V}

Final answer

Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s); Ecell∘=+1.105 VE^\circ_{\text{cell}} = +1.105\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize the mnemonic 'Red Cat' (Reduction at Cathode) and the order 'Cathode minus Anode' (E∘=Ecat∘−Ean∘E^\circ = E^\circ_{\text{cat}} - E^\circ_{\text{an}}).

  • Practice calculating cell potentials for different electrode pairs, always verifying that Ecell∘>0E^\circ_{\text{cell}} > 0 for spontaneous cells.

OverviewACEpath Teacher's Diagnosis

02 The student reverses the cathode and anode roles, assuming zinc undergoes reduction and copper undergoes oxidation.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Cu(s)+Zn2+(aq)→Cu2+(aq)+Zn(s)\text{Cu}(s) + \text{Zn}^{2+}(aq) \rightarrow \text{Cu}^{2+}(aq) + \text{Zn}(s)

    Correct

    Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s)

    You wrote the cell reaction for the oxidation of copper and reduction of zinc. In a spontaneous galvanic cell, zinc is oxidized and copper ion is reduced.

  2. Step 2

    Cathode: Zn2+/Zn, Anode: Cu2+/Cu\text{Cathode: } \text{Zn}^{2+}/\text{Zn}, \text{ Anode: } \text{Cu}^{2+}/\text{Cu}

    Correct

    Cathode: Cu2+/Cu, Anode: Zn2+/Zn\text{Cathode: } \text{Cu}^{2+}/\text{Cu}, \text{ Anode: } \text{Zn}^{2+}/\text{Zn}

    Because +0.342 V>−0.763 V+0.342\text{ V} > -0.763\text{ V}, copper ion has the higher reduction potential and is reduced at the cathode, while zinc is oxidized at the anode.

  3. Step 3

    Ecell∘=Ecathode∘−Eanode∘  ⟹  Ecell∘=−0.763 V−0.342 V  ⟹  Ecell∘=−1.105 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} \implies E^\circ_{\text{cell}} = -0.763\text{ V} - 0.342\text{ V} \implies E^\circ_{\text{cell}} = -1.105\text{ V}

    Correct

    Ecell∘=Ecathode∘−Eanode∘=+0.342 V−(−0.763 V)=+1.105 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.342\text{ V} - (-0.763\text{ V}) = +1.105\text{ V}

    You applied the formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} correctly with your assigned values, but the result is negative because the electrode assignments were reversed.

WHAT YOU DID WELL
Compliments from Your Teacher

You stated the correct relationship Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}}.

You performed the arithmetic subtraction accurately based on your assigned values.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Reversed cathode and anode assignments

You assigned the more negative reduction potential to the cathode instead of the anode.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You did not use the criterion that a galvanic cell must operate spontaneously (Ecell∘>0E^\circ_{\text{cell}} > 0), which requires the half-cell with the greater (more positive) reduction potential to act as the cathode.

REASONING PATH
Your ACEpath teacher’s suggested approach
Galvanic Spontaneity Rule
  • A standard galvanic cell operates spontaneously, so Ecell∘E^\circ_{\text{cell}} must always be positive.

  • Check the sign of Ecell∘E^\circ_{\text{cell}} at the end; if it is negative, you have reversed the cathode and anode.

Cathode vs. Anode Selection
  • Higher Ered∘→Cathode (Reduction);Lower Ered∘→Anode (Oxidation)\text{Higher } E^\circ_{\text{red}} \rightarrow \text{Cathode (Reduction)}; \quad \text{Lower } E^\circ_{\text{red}} \rightarrow \text{Anode (Oxidation)}.

  • Compare the standard reduction potentials directly before assigning electrodes.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Compare the standard reduction potentials: E∘(Cu2+/Cu)=+0.342 VE^\circ(\text{Cu}^{2+}/\text{Cu}) = +0.342\text{ V} and E∘(Zn2+/Zn)=−0.763 VE^\circ(\text{Zn}^{2+}/\text{Zn}) = -0.763\text{ V}.

  2. Assign the cathode to copper (reduction: Cu2+(aq)+2e−→Cu(s)\text{Cu}^{2+}(aq) + 2e^- \rightarrow \text{Cu}(s)) and the anode to zinc (oxidation: Zn(s)→Zn2+(aq)+2e−\text{Zn}(s) \rightarrow \text{Zn}^{2+}(aq) + 2e^-).

  3. Combine the half-reactions: Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s).

  4. Calculate Ecell∘=Ecathode∘−Eanode∘=+0.342 V−(−0.763 V)=+1.105 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.342\text{ V} - (-0.763\text{ V}) = +1.105\text{ V}.

Final answer

Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s); Ecell∘=+1.105 VE^\circ_{\text{cell}} = +1.105\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the convention that more positive reduction potentials drive reduction at the cathode in galvanic cells.

  • Practice identifying the cathode and anode across pairs of half-cells with mixed positive and negative standard reduction potentials.

  • Always perform a quick sanity check to confirm that your calculated Ecell∘E^\circ_{\text{cell}} is positive for any galvanic (voltaic) cell.

OverviewACEpath Teacher's Diagnosis

03 The student changes the sign of the oxidation potential when setting up the anode and then erroneously subtracts it in the standard formula, effectively subtracting twice.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s)

  2. Step 2

    Eox∘=+0.763 V  ⟹  Ecell∘=Ecathode∘−Eox∘  ⟹  Ecell∘=0.342 V−0.763 V=−0.421 VE^\circ_{\text{ox}} = +0.763\text{ V} \implies E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{ox}} \implies E^\circ_{\text{cell}} = 0.342\text{ V} - 0.763\text{ V} = -0.421\text{ V}

    Correct

    Ecell∘=Ecathode∘−Eanode∘=+0.342 V−(−0.763 V)=+1.105 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.342\text{ V} - (-0.763\text{ V}) = +1.105\text{ V}

    You mixed two different formulas for cell potential: Ecell∘=Ered∘(cathode)−Ered∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) - E^\circ_{\text{red}}(\text{anode}) and Ecell∘=Ered∘(cathode)+Eox∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) + E^\circ_{\text{ox}}(\text{anode}). By changing the sign to +0.763 V+0.763\text{ V} and then subtracting it, you reversed the sign twice, yielding a negative voltage for a spontaneous galvanic cell.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly determined that copper(II) is reduced at the cathode and solid zinc is oxidized at the anode.

You wrote the correct overall balanced net ionic equation.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
double sign reversal in cell potential

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Conflating the subtraction formula Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} (which uses standard reduction potentials for both electrodes) with the additive formula Ecell∘=Ered∘+Eox∘E^\circ_{\text{cell}} = E^\circ_{\text{red}} + E^\circ_{\text{ox}}, resulting in subtracting an already sign-reversed oxidation potential.

REASONING PATH
Your ACEpath teacher’s suggested approach
Choose one consistent cell potential formula
  • Either subtract reduction potentials: Ecell∘=Ered∘(cathode)−Ered∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) - E^\circ_{\text{red}}(\text{anode}), OR add the oxidation potential: Ecell∘=Ered∘(cathode)+Eox∘(anode)E^\circ_{\text{cell}} = E^\circ_{\text{red}}(\text{cathode}) + E^\circ_{\text{ox}}(\text{anode}).

  • Pick one convention and stick to it. Never subtract Eox∘E^\circ_{\text{ox}}.

Galvanic cell sanity check
  • A galvanic (voltaic) cell runs spontaneously, so its standard cell potential must always be positive (Ecell∘>0E^\circ_{\text{cell}} > 0).

  • If you calculate a negative cell potential for a standard galvanic cell, check immediately whether you reversed a sign improperly or swapped the cathode and anode.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify standard reduction potentials directly from the table: Ered∘(Cu2+/Cu)=+0.342 VE^\circ_{\text{red}}(\text{Cu}^{2+}/\text{Cu}) = +0.342\text{ V} and Ered∘(Zn2+/Zn)=−0.763 VE^\circ_{\text{red}}(\text{Zn}^{2+}/\text{Zn}) = -0.763\text{ V}.

  2. Apply the standard reduction formula: Ecell∘=Ecathode∘−Eanode∘=+0.342 V−(−0.763 V)E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.342\text{ V} - (-0.763\text{ V}).

  3. Evaluate: Ecell∘=+0.342 V+0.763 V=+1.105 VE^\circ_{\text{cell}} = +0.342\text{ V} + 0.763\text{ V} = +1.105\text{ V}.

Final answer

Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn}(s) + \text{Cu}^{2+}(aq) \rightarrow \text{Zn}^{2+}(aq) + \text{Cu}(s); Ecell∘=+1.105 VE^\circ_{\text{cell}} = +1.105\text{ V}

NEXT STEPS
Final Takeaways from Your Teacher
  • Memorize that standard electrochemical tables provide standard reduction potentials (Ered∘E^\circ_{\text{red}}).

  • Practice calculating cell potentials using Ecell∘=Ecathode∘−Eanode∘E^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} without modifying the tabulated signs before substitution.

Lock it in

Similar question

01

A galvanic cell is constructed with a silver electrode in 1.0 M Ag+1.0\text{ M }\text{Ag}^+ and a lead electrode in 1.0 M Pb2+1.0\text{ M }\text{Pb}^{2+}. Given E∘(Ag+/Ag)=+0.799 VE^\circ(\text{Ag}^+/\text{Ag}) = +0.799\text{ V} and E∘(Pb2+/Pb)=−0.126 VE^\circ(\text{Pb}^{2+}/\text{Pb}) = -0.126\text{ V}, identify the cathode and anode, and calculate Ecell∘E^\circ_{\text{cell}}.

Answer

Cathode: Ag; Anode: Pb. Ecell∘=Ecathode∘−Eanode∘=+0.799 V−(−0.126 V)=+0.925 VE^\circ_{\text{cell}} = E^\circ_{\text{cathode}} - E^\circ_{\text{anode}} = +0.799\text{ V} - (-0.126\text{ V}) = +0.925\text{ V}.

02

Consider the standard half-reactions: Fe3+(aq)+e−→Fe2+(aq)\text{Fe}^{3+}(aq) + e^- \rightarrow \text{Fe}^{2+}(aq) (E∘=+0.771 VE^\circ = +0.771\text{ V}) and Sn4+(aq)+2e−→Sn2+(aq)\text{Sn}^{4+}(aq) + 2e^- \rightarrow \text{Sn}^{2+}(aq) (E∘=+0.154 VE^\circ = +0.154\text{ V}). Write the balanced overall cell reaction for a galvanic cell and determine Ecell∘E^\circ_{\text{cell}}.

Answer

2Fe3+(aq)+Sn2+(aq)→2Fe2+(aq)+Sn4+(aq)2\text{Fe}^{3+}(aq) + \text{Sn}^{2+}(aq) \rightarrow 2\text{Fe}^{2+}(aq) + \text{Sn}^{4+}(aq); Ecell∘=+0.771 V−(+0.154 V)=+0.617 VE^\circ_{\text{cell}} = +0.771\text{ V} - (+0.154\text{ V}) = +0.617\text{ V}.

03

An electrochemical cell has the overall reaction Mg(s)+Cd2+(aq)→Mg2+(aq)+Cd(s)\text{Mg}(s) + \text{Cd}^{2+}(aq) \rightarrow \text{Mg}^{2+}(aq) + \text{Cd}(s) with Ecell∘=+1.967 VE^\circ_{\text{cell}} = +1.967\text{ V}. If E∘(Cd2+/Cd)=−0.403 VE^\circ(\text{Cd}^{2+}/\text{Cd}) = -0.403\text{ V}, find the standard reduction potential of the Mg2+/Mg\text{Mg}^{2+}/\text{Mg} half-reaction.

Answer

E∘(Mg2+/Mg)=−2.370 VE^\circ(\text{Mg}^{2+}/\text{Mg}) = -2.370\text{ V}. Since Cd is reduced at the cathode and Mg is oxidized at the anode: Ecell∘=ECd2+/Cd∘−EMg2+/Mg∘  ⟹  +1.967=−0.403−Eanode∘  ⟹  Eanode∘=−2.370 VE^\circ_{\text{cell}} = E^\circ_{\text{Cd}^{2+}/\text{Cd}} - E^\circ_{\text{Mg}^{2+}/\text{Mg}} \implies +1.967 = -0.403 - E^\circ_{\text{anode}} \implies E^\circ_{\text{anode}} = -2.370\text{ V}.

Loading workspace…