Resources

In a nuclear power reactor, a steady electrical output of 1.00×109 W1.00 \times 10^9\,\text{W} (1000 MW1000\,\text{MW}) is generated at an overall thermal-to-electric conversion efficiency of 33.0%33.0\%. The primary energy source is the fission of 92235U^{235}_{92}\text{U}, which yields 200.0 MeV200.0\,\text{MeV} of thermal energy per fission event (1 eV=1.602×10−19 J1\,\text{eV} = 1.602 \times 10^{-19}\,\text{J}). If each fission event releases an average of 2.432.43 neutrons and exactly 1.001.00 neutron per fission is required to sustain the critical chain reaction, calculate: (a) the total rate of fission events occurring per second in the reactor core, and (b) the mass of 92235U^{235}_{92}\text{U} consumed purely by fission over an operational period of 30.0 days30.0\,\text{days}, assuming a molar mass of 235.04 g/mol235.04\,\text{g/mol}.

Answer and steps

Final answer

(a) 9.46×1019 fissions/s9.46 \times 10^{19}\,\text{fissions/s}; (b) 96.8 kg96.8\,\text{kg}

Steps

Part (a): Fission Rate in the Reactor Core

  1. Determine the total thermal power generated (PthP_{\text{th}}): The electrical power output (PeP_{\text{e}}) is related to the thermal power by the conversion efficiency (η\eta): η=PePth  ⟹  Pth=Peη\eta = \frac{P_{\text{e}}}{P_{\text{th}}} \implies P_{\text{th}} = \frac{P_{\text{e}}}{\eta}

    Substitute the given values (Pe=1.00×109 WP_{\text{e}} = 1.00 \times 10^9\,\text{W} and η=0.330\eta = 0.330): Pth=1.00×109 W0.330≈3.0303×109 W(or J/s)P_{\text{th}} = \frac{1.00 \times 10^9\,\text{W}}{0.330} \approx 3.0303 \times 10^9\,\text{W}\quad (\text{or }\text{J/s})

  2. Convert the energy released per fission event to Joules (EfissE_{\text{fiss}}): Each fission event releases 200.0 MeV200.0\,\text{MeV}: Efiss=200.0 MeV×(106 eVMeV)×(1.602×10−19 JeV)=3.204×10−11 J/fissionE_{\text{fiss}} = 200.0\,\text{MeV} \times \left(10^6\,\frac{\text{eV}}{\text{MeV}}\right) \times \left(1.602 \times 10^{-19}\,\frac{\text{J}}{\text{eV}}\right) = 3.204 \times 10^{-11}\,\text{J/fission}
  3. Calculate the rate of fission events (RR): Divide the total thermal power by the energy released per individual fission: R=PthEfiss=3.0303×109 J/s3.204×10−11 J/fission≈9.46×1019 fissions/sR = \frac{P_{\text{th}}}{E_{\text{fiss}}} = \frac{3.0303 \times 10^9\,\text{J/s}}{3.204 \times 10^{-11}\,\text{J/fission}} \approx 9.46 \times 10^{19}\,\text{fissions/s}

(Note: The neutron yield of 2.432.43 neutrons and the 1.001.00 neutron needed to sustain criticality confirm that the reactor maintains a stable chain reaction, but they do not alter the direct energy balance between thermal output and fission rate.)


Part (b): Mass of 92235U^{235}_{92}\text{U} Consumed in 30.0 Days30.0\text{ Days}

  1. Calculate the total operating time in seconds (tt): t=30.0 days×24 hday×3600 sh=2.592×106 st = 30.0\,\text{days} \times 24\,\frac{\text{h}}{\text{day}} \times 3600\,\frac{\text{s}}{\text{h}} = 2.592 \times 10^6\,\text{s}
  2. Determine the total number of fissioned 92235U^{235}_{92}\text{U} nuclei (NN): N=R⋅t=(9.46×1019 s−1)⋅(2.592×106 s)≈2.45×1026 nucleiN = R \cdot t = (9.46 \times 10^{19}\,\text{s}^{-1}) \cdot (2.592 \times 10^6\,\text{s}) \approx 2.45 \times 10^{26}\,\text{nuclei}
  3. Convert the number of nuclei to mass (mm): Using Avogadro's number (NA≈6.022×1023 mol−1N_{\text{A}} \approx 6.022 \times 10^{23}\,\text{mol}^{-1}) and the molar mass of 235U^{235}\ce{U} (M=235.04 g/molM = 235.04\,\text{g/mol}): m=NNA⋅Mm = \frac{N}{N_{\text{A}}} \cdot M m=2.45×1026 nuclei6.022×1023 nuclei/mol×235.04 g/mol≈9.68×104 g=96.8 kgm = \frac{2.45 \times 10^{26}\,\text{nuclei}}{6.022 \times 10^{23}\,\text{nuclei/mol}} \times 235.04\,\text{g/mol} \approx 9.68 \times 10^4\,\text{g} = 96.8\,\text{kg}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student multiplies by efficiency instead of dividing by it to find the thermal power, underestimating the required fission rate and fuel consumed.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Pthermal=Pelectric×efficiency=1.00×109 W×0.330=3.30×108 WP_{\text{thermal}} = P_{\text{electric}} \times \text{efficiency} = 1.00 \times 10^9\,\text{W} \times 0.330 = 3.30 \times 10^8\,\text{W}

    Correct

    Pthermal=Pelectricη=1.00×109 W0.330≈3.03×109 WP_{\text{thermal}} = \frac{P_{\text{electric}}}{\eta} = \frac{1.00 \times 10^9\,\text{W}}{0.330} \approx 3.03 \times 10^9\,\text{W}

    Efficiency is defined as useful output over total input, η=PelectricPthermal\eta = \frac{P_{\text{electric}}}{P_{\text{thermal}}}. Because thermal power is the total input energy released by fission, it must be larger than the electrical output, so you need to divide PelectricP_{\text{electric}} by 0.3300.330.

  2. Step 2

    Efission=200.0×1.602×10−13 J=3.204×10−11 JE_{\text{fission}} = 200.0 \times 1.602 \times 10^{-13}\,\text{J} = 3.204 \times 10^{-11}\,\text{J}

  3. Step 3

    R=PthermalEfission=3.30×1083.204×10−11=1.03×1019 fissions/sR = \frac{P_{\text{thermal}}}{E_{\text{fission}}} = \frac{3.30 \times 10^8}{3.204 \times 10^{-11}} = 1.03 \times 10^{19}\,\text{fissions/s}

    Correct

    R=PthermalEfission=3.0303×109 J/s3.204×10−11 J/fission≈9.46×1019 fissions/sR = \frac{P_{\text{thermal}}}{E_{\text{fission}}} = \frac{3.0303 \times 10^9\,\text{J/s}}{3.204 \times 10^{-11}\,\text{J/fission}} \approx 9.46 \times 10^{19}\,\text{fissions/s}

    Your formula and division are mathematically sound, but the numerical answer is affected by the underestimated thermal power from Step 1.

  4. Step 4

    t=30.0×24×3600=2.592×106 st = 30.0 \times 24 \times 3600 = 2.592 \times 10^6\,\text{s}

  5. Step 5

    N=(1.03×1019)×(2.592×106)=2.67×1025 fissionsN = (1.03 \times 10^{19}) \times (2.592 \times 10^6) = 2.67 \times 10^{25}\,\text{fissions}

    Correct

    N=R⋅t=(9.46×1019 s−1)⋅(2.592×106 s)≈2.45×1026 fissionsN = R \cdot t = (9.46 \times 10^{19}\,\text{s}^{-1}) \cdot (2.592 \times 10^6\,\text{s}) \approx 2.45 \times 10^{26}\,\text{fissions}

    You correctly multiplied the fission rate by total time, though the numerical value carried over the error from Step 1.

  6. Step 6

    m=(2.67×10256.022×1023)×235.04 g/mol=10410 g=10.4 kgm = \left(\frac{2.67 \times 10^{25}}{6.022 \times 10^{23}}\right) \times 235.04\,\text{g/mol} = 10410\,\text{g} = 10.4\,\text{kg}

    Correct

    m=NNA⋅M=2.45×10266.022×1023 mol−1×235.04 g/mol≈9.68×104 g=96.8 kgm = \frac{N}{N_{\text{A}}} \cdot M = \frac{2.45 \times 10^{26}}{6.022 \times 10^{23}\,\text{mol}^{-1}} \times 235.04\,\text{g/mol} \approx 9.68 \times 10^4\,\text{g} = 96.8\,\text{kg}

    Your conversion from nuclei count to mass using Avogadro's number and molar mass is completely correct, but the result reflects the earlier thermal power error.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the energy per fission from MeV\text{MeV} to Joules.

You correctly recognized that dividing thermal power by energy per fission yields the fission rate.

You converted 30.0 days30.0\,\text{days} into seconds accurately.

You applied stoichiometry using Avogadro's constant and molar mass to find the consumed mass.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted thermal efficiency formula

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing input power with output power in the thermal efficiency definition η=PoutPin\eta = \frac{P_{\text{out}}}{P_{\text{in}}}, resulting in multiplying the electrical output by η\eta rather than dividing by it to determine the required thermal input.

REASONING PATH
Your ACEpath teacher’s suggested approach
Sanity check on thermal vs. electrical power
  • Real heat engines always lose energy to the surroundings, meaning Pin>PoutP_{\text{in}} > P_{\text{out}} (thermal power must be strictly greater than electrical power).

  • Whenever given an electrical output and an efficiency η<1\eta < 1, verify that your calculated thermal power is larger than the electrical power before continuing.

Efficiency definition
  • η=Useful OutputTotal Input=PePth\eta = \frac{\text{Useful Output}}{\text{Total Input}} = \frac{P_{\text{e}}}{P_{\text{th}}}, which rearranges to Pth=PeηP_{\text{th}} = \frac{P_{\text{e}}}{\eta}.

  • Write out η=PePth\eta = \frac{P_{\text{e}}}{P_{\text{th}}} explicitly and isolate the unknown variable symbolically before plugging in numbers.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Pthermal=Pelectricη=1.00×109 W0.330≈3.0303×109 WP_{\text{thermal}} = \frac{P_{\text{electric}}}{\eta} = \frac{1.00 \times 10^9\,\text{W}}{0.330} \approx 3.0303 \times 10^9\,\text{W}

  2. R=PthermalEfission=3.0303×109 J/s3.204×10−11 J/fission≈9.46×1019 fissions/sR = \frac{P_{\text{thermal}}}{E_{\text{fission}}} = \frac{3.0303 \times 10^9\,\text{J/s}}{3.204 \times 10^{-11}\,\text{J/fission}} \approx 9.46 \times 10^{19}\,\text{fissions/s}

  3. N=R⋅t=(9.46×1019 s−1)⋅(2.592×106 s)≈2.451×1026 fissionsN = R \cdot t = (9.46 \times 10^{19}\,\text{s}^{-1}) \cdot (2.592 \times 10^6\,\text{s}) \approx 2.451 \times 10^{26}\,\text{fissions}

  4. m=NNA⋅M=2.451×10266.022×1023 mol−1×235.04 g/mol≈9.57×104 g=96.8 kgm = \frac{N}{N_{\text{A}}} \cdot M = \frac{2.451 \times 10^{26}}{6.022 \times 10^{23}\,\text{mol}^{-1}} \times 235.04\,\text{g/mol} \approx 9.57 \times 10^4\,\text{g} = 96.8\,\text{kg}

Final answer

(a) 9.46×1019 fissions/s9.46 \times 10^{19}\,\text{fissions/s}; (b) 96.8 kg96.8\,\text{kg}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the relationship between input thermal energy and output electrical energy in heat engines.

  • Practice isolating variables symbolically before substituting numerical values to prevent inversion slips.

OverviewACEpath Teacher's Diagnosis

02 The student ignores the conversion efficiency entirely and equates the thermal power directly to electrical power output.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Efission=200.0×1.602×10−13 J=3.204×10−11 JE_{\text{fission}} = 200.0 \times 1.602 \times 10^{-13}\,\text{J} = 3.204 \times 10^{-11}\,\text{J}

  2. Step 2

    P=1.00×109 W  ⟹  R=PEfission=1.00×1093.204×10−11=3.12×1019 fissions/sP = 1.00 \times 10^9\,\text{W} \implies R = \frac{P}{E_{\text{fission}}} = \frac{1.00 \times 10^9}{3.204 \times 10^{-11}} = 3.12 \times 10^{19}\,\text{fissions/s}

    Correct

    Pth=Peη=1.00×109 W0.330≈3.0303×109 W  ⟹  R=PthEfiss=3.0303×109 J/s3.204×10−11 J≈9.46×1019 fissions/sP_{\text{th}} = \frac{P_{\text{e}}}{\eta} = \frac{1.00 \times 10^9\,\text{W}}{0.330} \approx 3.0303 \times 10^9\,\text{W} \implies R = \frac{P_{\text{th}}}{E_{\text{fiss}}} = \frac{3.0303 \times 10^9\,\text{J/s}}{3.204 \times 10^{-11}\,\text{J}} \approx 9.46 \times 10^{19}\,\text{fissions/s}

    You used the net electrical power output (1.00×109 W1.00 \times 10^9\,\text{W}) directly instead of calculating the total thermal power generated in the reactor core (Pth=PeηP_{\text{th}} = \frac{P_{\text{e}}}{\eta}). Because the conversion efficiency is 33.0%33.0\%, the reactor must produce about three times more thermal power than electrical power.

  3. Step 3

    t=30.0×24×3600=2.592×106 s  ⟹  N=(3.121×1019)×(2.592×106)=8.09×1025 fissionst = 30.0 \times 24 \times 3600 = 2.592 \times 10^6\,\text{s} \implies N = (3.121 \times 10^{19}) \times (2.592 \times 10^6) = 8.09 \times 10^{25}\,\text{fissions}

    Correct

    t=30.0×24×3600=2.592×106 s  ⟹  N=R⋅t=(9.46×1019 s−1)(2.592×106 s)≈2.45×1026 fissionst = 30.0 \times 24 \times 3600 = 2.592 \times 10^6\,\text{s} \implies N = R \cdot t = (9.46 \times 10^{19}\,\text{s}^{-1})(2.592 \times 10^6\,\text{s}) \approx 2.45 \times 10^{26}\,\text{fissions}

    Your conversion of 30.0 days30.0\,\text{days} to seconds and your multiplication of rate by time were set up correctly, but the numerical result was affected by the initial fission rate error.

  4. Step 4

    m=8.09×10256.022×1023×235.04 g/mol=31575 g=31.6 kgm = \frac{8.09 \times 10^{25}}{6.022 \times 10^{23}} \times 235.04\,\text{g/mol} = 31575\,\text{g} = 31.6\,\text{kg}

    Correct

    m=NNA⋅M=2.45×10266.022×1023 mol−1×235.04 g/mol≈9.68×104 g=96.8 kgm = \frac{N}{N_{\text{A}}} \cdot M = \frac{2.45 \times 10^{26}}{6.022 \times 10^{23}\,\text{mol}^{-1}} \times 235.04\,\text{g/mol} \approx 9.68 \times 10^4\,\text{g} = 96.8\,\text{kg}

    Your stoichiometric calculation converting the number of fissioned nuclei to mass was set up correctly, but the result carried forward the earlier power efficiency omission.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted the energy released per fission event from MeV\text{MeV} to Joules.

You correctly converted the operation time of 30.0 days30.0\,\text{days} into seconds.

You used Avogadro's number and the given molar mass properly to convert total fission events into grams and kilograms.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of Thermal-to-Electric Efficiency

You equated the reactor's gross thermal power directly to its electrical output without accounting for the 33.0%33.0\% conversion efficiency.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing electrical power output (PeP_{\text{e}}) with total thermal power generation (PthP_{\text{th}}). In thermal power plants, nuclear fission provides thermal energy, only a fraction η\eta of which becomes electricity (Pe=ηPthP_{\text{e}} = \eta P_{\text{th}}). The rate of fission depends directly on the total thermal power produced, so Pth=Peη>PeP_{\text{th}} = \frac{P_{\text{e}}}{\eta} > P_{\text{e}}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Distinguish Electrical vs. Thermal Power
  • η=PelectricalPthermal  ⟹  Pthermal=Pelectricalη\eta = \frac{P_{\text{electrical}}}{P_{\text{thermal}}} \implies P_{\text{thermal}} = \frac{P_{\text{electrical}}}{\eta}

  • Always convert electrical output to required thermal power before computing reaction or fuel burnup rates.

Sanity Check on Power and Efficiency
  • Because η<1\eta < 1, thermal power must always be larger than electrical power output.

  • Verify that your calculated fuel consumption rate is larger than what 100%100\% efficiency would require.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Determine the thermal power: Pth=Peη=1.00×109 W0.330≈3.0303×109 WP_{\text{th}} = \frac{P_{\text{e}}}{\eta} = \frac{1.00 \times 10^9\,\text{W}}{0.330} \approx 3.0303 \times 10^9\,\text{W}.

  2. Recalculate the fission rate: R=PthEfiss=3.0303×109 J/s3.204×10−11 J/fission≈9.46×1019 fissions/sR = \frac{P_{\text{th}}}{E_{\text{fiss}}} = \frac{3.0303 \times 10^9\,\text{J/s}}{3.204 \times 10^{-11}\,\text{J/fission}} \approx 9.46 \times 10^{19}\,\text{fissions/s}.

  3. Compute the total fissioned nuclei over 30.0 days30.0\,\text{days} (2.592×106 s2.592 \times 10^6\,\text{s}): N=R⋅t=(9.458×1019 s−1)(2.592×106 s)≈2.451×1026 fissionsN = R \cdot t = (9.458 \times 10^{19}\,\text{s}^{-1})(2.592 \times 10^6\,\text{s}) \approx 2.451 \times 10^{26}\,\text{fissions}.

  4. Calculate the consumed mass: m=2.451×1026 nuclei6.022×1023 mol−1×235.04 g/mol≈9.567×104 g=96.8 kgm = \frac{2.451 \times 10^{26}\,\text{nuclei}}{6.022 \times 10^{23}\,\text{mol}^{-1}} \times 235.04\,\text{g/mol} \approx 9.567 \times 10^4\,\text{g} = 96.8\,\text{kg}.

Final answer

(a) 9.46×1019 fissions/s9.46 \times 10^{19}\,\text{fissions/s}; (b) 96.8 kg96.8\,\text{kg}

NEXT STEPS
Final Takeaways from Your Teacher
  • In future multi-stage power problems, highlight whether a given power is 'electrical' or 'thermal' at the start.

  • Write out the efficiency relationship η=PoutPin\eta = \frac{P_{\text{out}}}{P_{\text{in}}} explicitly before plugging in values.

  • Practice checking whether your fuel consumption increases as plant efficiency decreases.

OverviewACEpath Teacher's Diagnosis

03 The student misinterprets the neutron release data and divides the fission rate by 2.43 neutrons per fission, believing only a fraction of fissions produce energy.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Pthermal=1.00×1090.330=3.0303×109 WP_{\text{thermal}} = \frac{1.00 \times 10^9}{0.330} = 3.0303 \times 10^9\,\text{W}

  2. Step 2

    Efission=200.0×1.602×10−13 J=3.204×10−11 JE_{\text{fission}} = 200.0 \times 1.602 \times 10^{-13}\,\text{J} = 3.204 \times 10^{-11}\,\text{J}

  3. Step 3

    Rtotal=3.0303×1093.204×10−11=9.46×1019 fissions/sR_{\text{total}} = \frac{3.0303 \times 10^9}{3.204 \times 10^{-11}} = 9.46 \times 10^{19}\,\text{fissions/s}

  4. Step 4

    R=9.46×10192.43=3.89×1019 fissions/sR = \frac{9.46 \times 10^{19}}{2.43} = 3.89 \times 10^{19}\,\text{fissions/s}

    Correct

    R=9.46×1019 fissions/sR = 9.46 \times 10^{19}\,\text{fissions/s}

    You divided the fission rate by 2.432.43 neutrons per fission. Each single fission event already produces the full 200.0 MeV200.0\,\text{MeV} of thermal energy regardless of how many neutrons are emitted, so dividing by the neutron multiplicity is an extraneous adjustment.

  5. Step 5

    t=30.0×24×3600=2.592×106 s  ⟹  N=(3.892×1019)×(2.592×106)=1.009×1026 fissionst = 30.0 \times 24 \times 3600 = 2.592 \times 10^6\,\text{s} \implies N = (3.892 \times 10^{19}) \times (2.592 \times 10^6) = 1.009 \times 10^{26}\,\text{fissions}

    Correct

    N=R⋅t=(9.46×1019 s−1)⋅(2.592×106 s)≈2.45×1026 fissionsN = R \cdot t = (9.46 \times 10^{19}\,\text{s}^{-1}) \cdot (2.592 \times 10^6\,\text{s}) \approx 2.45 \times 10^{26}\,\text{fissions}

    Your conversion of operational time into seconds and multiplication by your fission rate followed the correct method, but your result was affected by the lower fission rate from Step 4.

  6. Step 6

    m=(1.009×10266.022×1023)×235.04 g/mol=3.94×104 g=39.4 kgm = \left(\frac{1.009 \times 10^{26}}{6.022 \times 10^{23}}\right) \times 235.04\,\text{g/mol} = 3.94 \times 10^4\,\text{g} = 39.4\,\text{kg}

    Correct

    m=NNA⋅M=2.45×10266.022×1023 mol×235.04 g/mol≈9.68×104 g=96.8 kgm = \frac{N}{N_{\text{A}}} \cdot M = \frac{2.45 \times 10^{26}}{6.022 \times 10^{23}}\,\text{mol} \times 235.04\,\text{g/mol} \approx 9.68 \times 10^4\,\text{g} = 96.8\,\text{kg}

    Your conversion from total nuclei to grams and kilograms using Avogadro's number and molar mass was conceptually sound, but the final mass carried over the numerical error from Step 4.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used the conversion efficiency to relate electrical power to thermal power.

You accurately converted MeV\text{MeV} per fission to Joules.

You converted operational time in days to seconds without error.

You used Avogadro's constant and molar mass correctly to convert the number of fissioned nuclei into mass.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Misapplying extraneous neutron yield to energy balance

You divided your calculated fission rate by 2.432.43, treating neutron emission as if it diluted or partitioned the energy released per fission.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the kinetic/energy balance of a nuclear reaction with the neutron population balance needed for criticality. The energy value of 200.0 MeV200.0\,\text{MeV} applies to each single fission event in its entirety; the neutron yield (2.432.43) describes chain-reaction multiplication and does not divide the fission count.

REASONING PATH
Your ACEpath teacher’s suggested approach
Energy Balance vs. Neutron Economy
  • Total thermal power equals the number of fission events per second multiplied by the energy released per fission: Pth=R⋅EfissP_{\text{th}} = R \cdot E_{\text{fiss}}.

  • Always determine the event rate directly from power and energy per event without modifying it by secondary particle yields such as neutrons or gamma photons.

Identifying Distractor Data
  • Neutron multiplication factors or emitted neutron counts per fission describe reactor control and criticality conditions (k=1.00k = 1.00), not the energy released per nucleus.

  • Check the units of each given quantity before including it in an equation; dividing a rate in fissions/s\text{fissions/s} by a unit of neutrons/fission\text{neutrons/fission} yields fissions2/(neutrons⋅s)\text{fissions}^2/(\text{neutrons} \cdot \text{s}), which is dimensionally incorrect for a fission event rate.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. State Part (a) directly: R=9.46×1019 fissions/sR = 9.46 \times 10^{19}\,\text{fissions/s}.

  2. Calculate total fission events over 30.0 days30.0\,\text{days}: N=R⋅t=(9.46×1019 s−1)(2.592×106 s)=2.452×1026 fissionsN = R \cdot t = (9.46 \times 10^{19}\,\text{s}^{-1})(2.592 \times 10^6\,\text{s}) = 2.452 \times 10^{26}\,\text{fissions}.

  3. Convert to consumed mass: m=2.452×10266.022×1023 mol−1×235.04 g/mol=9.57×104 g≈96.8 kgm = \frac{2.452 \times 10^{26}}{6.022 \times 10^{23}\,\text{mol}^{-1}} \times 235.04\,\text{g/mol} = 9.57 \times 10^4\,\text{g} \approx 96.8\,\text{kg}.

Final answer

(a) 9.46×1019 fissions/s9.46 \times 10^{19}\,\text{fissions/s}; (b) 96.8 kg96.8\,\text{kg}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice checking the physical units of each step to catch dimensional inconsistencies when combining reaction rates with particle yields.

  • Solve problems involving nuclear reactors where both criticality parameters and energy outputs are given, explicitly sorting given values into 'energy balance' versus 'neutron lifecycle' categories.

Lock it in

Similar question

01

A small nuclear research reactor generates 15.0 MW15.0\,\text{MW} of thermal power. If each fission of 235U^{235}\text{U} releases 200.0 MeV200.0\,\text{MeV} (3.204×10−11 J3.204 \times 10^{-11}\,\text{J}), calculate the fission rate in fissions per second.

Answer

R=PthEfiss=15.0×106 W3.204×10−11 J/fission≈4.68×1017 fissions/sR = \frac{P_{\text{th}}}{E_{\text{fiss}}} = \frac{15.0 \times 10^6\,\text{W}}{3.204 \times 10^{-11}\,\text{J/fission}} \approx 4.68 \times 10^{17}\,\text{fissions/s}.

02

A nuclear power plant supplies 900.0 MW900.0\,\text{MW} of electrical power with an efficiency of 36.0%36.0\%. Each fission yields 200.0 MeV200.0\,\text{MeV} (3.204×10−11 J3.204 \times 10^{-11}\,\text{J}). How many fission events occur in 1.00 hour1.00\,\text{hour} of operation?

Answer
  1. Thermal power: Pth=900.0×106 W0.360=2.50×109 WP_{\text{th}} = \frac{900.0 \times 10^6\,\text{W}}{0.360} = 2.50 \times 10^9\,\text{W}.\n2. Fission rate: R=2.50×1093.204×10−11≈7.803×1019 fissions/sR = \frac{2.50 \times 10^9}{3.204 \times 10^{-11}} \approx 7.803 \times 10^{19}\,\text{fissions/s}.\n3. Total fissions in 3600 s3600\,\text{s}: N=(7.803×1019)×3600≈2.81×1023 fissionsN = (7.803 \times 10^{19}) \times 3600 \approx 2.81 \times 10^{23}\,\text{fissions}.
03

A spacecraft nuclear generator produces 500.0 W500.0\,\text{W} of electrical power from 239Pu^{239}\text{Pu} fission (207.0 MeV=3.316×10−11 J207.0\,\text{MeV} = 3.316 \times 10^{-11}\,\text{J} per event) at a thermoelectric efficiency of 8.00%8.00\%. Calculate the mass of 239Pu^{239}\text{Pu} (M=239.05 g/molM = 239.05\,\text{g/mol}) consumed over 1.00 year1.00\,\text{year} (3.154×107 s3.154 \times 10^7\,\text{s}).

Answer
  1. Thermal power: Pth=500.0 W0.0800=6250 WP_{\text{th}} = \frac{500.0\,\text{W}}{0.0800} = 6250\,\text{W}.\n2. Fission rate: R=62503.316×10−11≈1.885×1014 fissions/sR = \frac{6250}{3.316 \times 10^{-11}} \approx 1.885 \times 10^{14}\,\text{fissions/s}.\n3. Total fissions: N=R⋅t=(1.885×1014)×(3.154×107)≈5.945×1021 nucleiN = R \cdot t = (1.885 \times 10^{14}) \times (3.154 \times 10^7) \approx 5.945 \times 10^{21}\,\text{nuclei}.\n4. Mass consumed: m=5.945×10216.022×1023×239.05 g/mol≈2.36 gm = \frac{5.945 \times 10^{21}}{6.022 \times 10^{23}} \times 239.05\,\text{g/mol} \approx 2.36\,\text{g}.
Loading workspace…