Resources
A sample of petroleum distillate is reported by an international refinery to have a density of . A quality control laboratory performs an automated pycnometer measurement and records the density as . Given the exact unit conversions , , and , convert the refinery's benchmark density into and determine the percent error of the automated pycnometer measurement relative to the refinery benchmark.
Answer and steps
Final answer
Refinery benchmark density: ; Pycnometer density: ; Percent error:
Steps
Convert the refinery benchmark density to
To convert the density from to , apply dimensional analysis to convert mass from pounds () to grams () and volume from cubic feet () to cubic centimeters ().
- Mass conversion:
- Volume conversion: First, convert feet to centimeters: Cubing both sides gives:
- Combined conversion:
Convert the pycnometer measurement to
The automated pycnometer records a density in milligrams per cubic centimeter (). Using the metric prefix factor :
Calculate the percent error
The percent error compares the experimental measurement () to the reference benchmark ():
Using the benchmark density rounded to three significant figures ():
Common Pitfall: When cubing linear conversion factors such as , remember to cube the numerical value as well as the unit: , not .
Typical errors
01 The student forgets to cube the linear conversion factor when converting cubic feet to cubic centimeters, resulting in a drastically overestimated benchmark density.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You found that , but you divided by instead of cubing the number: .
- Step 3
- Step 4Correct
You used the standard percent error formula correctly, but your result was distorted by the incorrect benchmark density from Step 2.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly converted pounds to grams.
You converted milligrams per cubic centimeter to grams per cubic centimeter without error.
You set up the percent error expression with the correct relative error structure.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisWhen converting a volume unit such as cubic feet to cubic centimeters, both the unit and the conversion factor must be raised to the third power: , rather than simply attaching to the linear factor .
REASONING PATH
Your ACEpath teacher’s suggested approach- Cube the Entire Conversion Factor
For any linear conversion , the volume equivalence is .
Always write out parentheses around the entire conversion factor before expanding: .
- Reality-Check Density Values
Typical petroleum products and organic liquids have densities near .
If a liquid's calculated density is over (heavier than solid gold or osmium), immediately check whether a volume factor was cubed.
CORRECTED PATH
ACEpath Teacher's DemonstrationRefinery benchmark density: ; Pycnometer density: ; Percent error: $+0.81%
02 The student calculates percent error dividing by the experimental measurement instead of the accepted benchmark value.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You placed the experimental value () in the denominator instead of the accepted benchmark value (). Percent error measures deviation relative to the accepted standard, so the accepted value must be the base.
WHAT YOU DID WELL
Compliments from Your TeacherYou properly converted feet to centimeters and cubed both the numerical value and unit to obtain the correct volume conversion factor.
You accurately performed the dimensional analysis to convert the refinery benchmark density to three significant figures.
You correctly converted the experimental pycnometer density from to .
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou treated the experimental value as the reference base in the percent error denominator rather than normalizing by the accepted reference benchmark.
REASONING PATH
Your ACEpath teacher’s suggested approach- Percent Error Reference Base
Always identify which quantity represents the known reference standard (accepted/theoretical value) and place that exact quantity in the denominator.
CORRECTED PATH
ACEpath Teacher's DemonstrationSubstitute the accepted benchmark density () into the denominator: .
Evaluate the numerator: .
Divide by the benchmark value: .
03 The student multiplies by 1000 instead of dividing when converting mg/cm³ to g/cm³, confusing milligrams with grams.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
Because , converting from a smaller unit () to a larger unit () requires dividing by , not multiplying.
- Step 3Correct
Your percent error formula structure was set up correctly, but the result was distorted by the incorrect experimental density from the previous step.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the volume of a cubic foot in cubic centimeters as .
You accurately converted the benchmark density from to .
You correctly set up the relative percent error formula as .
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou multiplied by rather than dividing when converting milligrams to grams.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisInverting metric prefix conversion ratios occurs when setting up conversion factors without writing out canceling units. Remembering that a milligram is smaller than a gram ensures the numerical value must decrease when converting to .
REASONING PATH
Your ACEpath teacher’s suggested approach- Unit Cancellation Check
Always write metric conversion factors with units explicitly aligned: in the denominator, in the numerator.
Write so that explicitly cancels, leaving .
- Magnitude Sanity Check
Going from a smaller unit to a larger unit must yield a smaller number.
Check whether is physically plausible for petroleum distillate; typical liquid fuels have densities near .
CORRECTED PATH
ACEpath Teacher's DemonstrationRefinery benchmark density: ; Pycnometer density: ; Percent error:
Lock it in
When converting a volume unit using a linear conversion factor , how do you express in ?
. Remember to cube both the number and the unit.
Similar question
Convert a density of (the density of water) into . Use and .
Answer
. Key step: .
An alloy has a reference density of . A technician measures its density as . Calculate the percent error of the measurement relative to the reference value.
Answer
. Key step: .
A gaseous pollutant has a concentration of . Convert this concentration to (, ).
Answer
. Key step: .