Resources

In the chlor-alkali membrane cell process, brine is electrolyzed: 2 NaCl(aq)+2 H2O(l)→2 NaOH(aq)+Cl2(g)+H2(g)2\,\text{NaCl}(aq) + 2\,\text{H}_2\text{O}(l) \rightarrow 2\,\text{NaOH}(aq) + \text{Cl}_2(g) + \text{H}_2(g), with standard thermodynamic reversible cell potential Erev∘=−2.19 VE_{\text{rev}}^\circ = -2.19\,\text{V}. In a commercial chlor-alkali plant operating at current I=1.20×105 AI = 1.20 \times 10^5\,\text{A}, overpotentials and ohmic membrane resistances cause the actual cell voltage to increase asymptotically with current density according to Vcell(j)=2.20+0.35 ln⁡(1+0.80 j)+0.15 jV_{\text{cell}}(j) = 2.20 + 0.35\,\ln(1 + 0.80\,j) + 0.15\,j, where jj is the current density in kA/m2\text{kA/m}^2. At the industrial operating point of j=4.00 kA/m2j = 4.00\,\text{kA/m}^2 with a current efficiency of ηcurr=95.0%\eta_{\text{curr}} = 95.0\%, Faraday's constant is F=96485 C/molF = 96485\,\text{C/mol}. Calculate: (a) the actual cell operating potential VcellV_{\text{cell}}, (b) the electrochemical electrical energy efficiency εenergy=Erev∘×ηcurrVcell\varepsilon_{\text{energy}} = \frac{E_{\text{rev}}^\circ \times \eta_{\text{curr}}}{V_{\text{cell}}}, and (c) the specific electrical energy consumption in kilowatt-hours per metric ton of Cl2\text{Cl}_2 produced (molar mass Cl2=70.90 g/mol\text{Cl}_2 = 70.90\,\text{g/mol}).

Answer and steps

Final answer

(a) Vcell=3.30 VV_{\text{cell}} = 3.30\,\text{V}; (b) εenergy=63.1%\varepsilon_{\text{energy}} = 63.1\%; (c) Specific energy consumption=2.63×103 kWh/metric ton Cl2\text{Specific energy consumption} = 2.63 \times 10^3\,\text{kWh/metric ton } \text{Cl}_2.

Steps

01

Calculate the actual cell operating potential VcellV_{\text{cell}}

The actual voltage across the membrane cell accounts for the reversible potential, activation overpotentials, and ohmic resistance losses. Substituting the operating current density j=4.00 kA/m2j = 4.00\,\text{kA/m}^2 into the empirical cell voltage equation:

Vcell(4.00)=2.20+0.35ln⁡(1+0.80⋅4.00)+0.15(4.00)V_{\text{cell}}(4.00) = 2.20 + 0.35\ln(1 + 0.80 \cdot 4.00) + 0.15(4.00)

Evaluate each term:

  • Argument of the logarithm: 1+0.80⋅4.00=1+3.20=4.201 + 0.80 \cdot 4.00 = 1 + 3.20 = 4.20
  • Overpotential term: 0.35ln⁡(4.20)≈0.35⋅1.4351≈0.502 V0.35\ln(4.20) \approx 0.35 \cdot 1.4351 \approx 0.502\,\text{V}
  • Ohmic drop term: 0.15⋅4.00=0.60 V0.15 \cdot 4.00 = 0.60\,\text{V}

Summing these components:

Vcell=2.20+0.502+0.60=3.302 V≈3.30 VV_{\text{cell}} = 2.20 + 0.502 + 0.60 = 3.302\,\text{V} \approx 3.30\,\text{V}


02

Calculate the electrochemical electrical energy efficiency εenergy\varepsilon_{\text{energy}}

The electrical energy efficiency compares the theoretical minimum energy required to the actual electrical energy consumed, which is the product of voltage efficiency and current efficiency ηcurr\eta_{\text{curr}}:

εenergy=∣Erev∘∣⋅ηcurrVcell\varepsilon_{\text{energy}} = \frac{|E_{\text{rev}}^\circ| \cdot \eta_{\text{curr}}}{V_{\text{cell}}}

Given ∣Erev∘∣=2.19 V|E_{\text{rev}}^\circ| = 2.19\,\text{V}, ηcurr=95.0%=0.950\eta_{\text{curr}} = 95.0\% = 0.950, and Vcell=3.30 VV_{\text{cell}} = 3.30\,\text{V}:

εenergy=2.19 V⋅0.9503.30 V=2.0805 V3.30 V≈0.6305=63.1%\varepsilon_{\text{energy}} = \frac{2.19\,\text{V} \cdot 0.950}{3.30\,\text{V}} = \frac{2.0805\,\text{V}}{3.30\,\text{V}} \approx 0.6305 = 63.1\%


03

Calculate the specific electrical energy consumption per metric ton of ClX2\ce{Cl2}

The half-reaction for chlorine gas generation at the anode is:

2 ClX−(aq)→ClX2(g)+2 e−2\,\ce{Cl-}(aq) \rightarrow \ce{Cl2}(g) + 2\,\text{e}^-

This indicates that z=2z = 2 moles of electrons are required per mole of ClX2\ce{Cl2} produced.

  1. Calculate the moles of ClX2\ce{Cl2} in 11 metric ton (106 g10^6\,\text{g}):

    nClX2=1.00×106 g70.90 g/mol≈1.4104×104 moln_{\ce{Cl2}} = \frac{1.00 \times 10^6\,\text{g}}{70.90\,\text{g/mol}} \approx 1.4104 \times 10^4\,\text{mol}

  2. Calculate the actual electric charge (QactualQ_{\text{actual}}) required:

    Accounting for the current efficiency ηcurr\eta_{\text{curr}}:

    Qactual=nClX2⋅z⋅Fηcurr=1.4104×104 mol⋅2⋅96485 C/mol0.950≈2.865×109 CQ_{\text{actual}} = \frac{n_{\ce{Cl2}} \cdot z \cdot F}{\eta_{\text{curr}}} = \frac{1.4104 \times 10^4\,\text{mol} \cdot 2 \cdot 96485\,\text{C/mol}}{0.950} \approx 2.865 \times 10^9\,\text{C}

  3. Calculate the energy consumption in kilowatt-hours (kWh\text{kWh}):

    Electrical energy consumed is Econsumed=Qactual⋅VcellE_{\text{consumed}} = Q_{\text{actual}} \cdot V_{\text{cell}}:

    Econsumed=2.865×109 C⋅3.30 V≈9.454×109 JE_{\text{consumed}} = 2.865 \times 10^9\,\text{C} \cdot 3.30\,\text{V} \approx 9.454 \times 10^9\,\text{J}

    Converting joules to kilowatt-hours (1 kWh=3.60×106 J1\,\text{kWh} = 3.60 \times 10^6\,\text{J}):

    Specific energy consumption=9.454×109 J3.60×106 J/kWh≈2.63×103 kWh/metric ton ClX2\text{Specific energy consumption} = \frac{9.454 \times 10^9\,\text{J}}{3.60 \times 10^6\,\text{J/kWh}} \approx 2.63 \times 10^3\,\text{kWh/metric ton }\ce{Cl2}

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets that chlorine gas formation from chloride oxidation is a 2-electron process and uses z = 1, halving the calculated specific energy consumption.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Vcell=2.20+0.35ln⁡(1+0.80×4.00)+0.15×4.00  ⟹  Vcell=2.20+0.35ln⁡(4.20)+0.60=3.30 VV_{\text{cell}} = 2.20 + 0.35\ln(1 + 0.80 \times 4.00) + 0.15 \times 4.00 \implies V_{\text{cell}} = 2.20 + 0.35\ln(4.20) + 0.60 = 3.30\text{ V}

  2. Step 2

    εenergy=2.19×0.9503.30=0.630=63.0%\varepsilon_{\text{energy}} = \frac{2.19 \times 0.950}{3.30} = 0.630 = 63.0\%

  3. Step 3

    n(Cl2)=14104 moln(\text{Cl}_2) = 14104\text{ mol}, z=1 mol e−/mol Cl2z = 1\text{ mol }\text{e}^-/\text{mol }\text{Cl}_2

    Correct

    n(Cl2)=106 g70.90 g/mol≈1.4104×104 moln(\text{Cl}_2) = \frac{10^6\text{ g}}{70.90\text{ g/mol}} \approx 1.4104 \times 10^4\text{ mol}, z=2 mol e−/mol Cl2z = 2\text{ mol }\text{e}^-/\text{mol }\text{Cl}_2

    You determined the molar amount of ClX2\ce{Cl2} accurately, but the anodic oxidation is 2ClX−→ClX2+2eX−2\ce{Cl-} \rightarrow \ce{Cl2} + 2\ce{e-}, which requires z=2z = 2 moles of electrons per mole of diatomic chlorine gas produced.

  4. Step 4

    Q=14104×964850.950=1.432×109 C  ⟹  Energy=3.30 V×1.432×109 C=4.726×109 J  ⟹  Specific energy=4.726×1093.6×106=1313 kWh/tQ = \frac{14104 \times 96485}{0.950} = 1.432 \times 10^9\text{ C} \implies \text{Energy} = 3.30\text{ V} \times 1.432 \times 10^9\text{ C} = 4.726 \times 10^9\text{ J} \implies \text{Specific energy} = \frac{4.726 \times 10^9}{3.6 \times 10^6} = 1313\text{ kWh/t}

    Correct

    Qactual=1.4104×104×2×964850.950≈2.865×109 C  ⟹  Specific energy=2.865×109 C×3.30 V3.60×106 J/kWh≈2.63×103 kWh/metric ton ClX2Q_{\text{actual}} = \frac{1.4104 \times 10^4 \times 2 \times 96485}{0.950} \approx 2.865 \times 10^9\text{ C} \implies \text{Specific energy} = \frac{2.865 \times 10^9\text{ C} \times 3.30\text{ V}}{3.60 \times 10^6\text{ J/kWh}} \approx 2.63 \times 10^3\text{ kWh/metric ton }\ce{Cl2}

    Your formulas for Faraday's law, electrical energy, and unit conversion from joules to kilowatt-hours were applied correctly, but the result is exactly half the correct value because of the incorrect value of zz.

WHAT YOU DID WELL
Compliments from Your Teacher

You substituted the operational parameters accurately into the empirical cell voltage equation.

You used the standard thermodynamic potential and current efficiency correctly to find the overall energy efficiency.

You executed the unit conversions from metric tons to moles and joules to kilowatt-hours properly.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Stoichiometric electron transfer number error

You assigned z=1z = 1 instead of z=2z = 2 for the oxidation of chloride to molecular chlorine.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You likely associated the single negative charge of a chloride ion (ClX−\ce{Cl-}) with the electron number per mole of product, forgetting that chlorine gas is diatomic (ClX2\ce{Cl2}), meaning each molecule formed requires the transfer of two electrons.

REASONING PATH
Your ACEpath teacher’s suggested approach
Anodic Half-Reaction Stoichiometry
  • For gas evolution reactions involving diatomic species (ClX2\ce{Cl2}, HX2\ce{H2}, OX2\ce{O2}), the electron number zz must reflect the electrons transferred per molecule of gas formed, not per precursor ion.

  • Always write out the balanced half-reaction (2ClX−→ClX2+2eX−2\ce{Cl-} \rightarrow \ce{Cl2} + 2\ce{e-}) before applying Faraday's law to confirm the value of zz.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Write the balanced oxidation half-reaction: 2ClX−(aq)→ClX2(g)+2eX−2\ce{Cl-}(aq) \rightarrow \ce{Cl2}(g) + 2\ce{e-}, giving z=2 mol e−/mol ClX2z = 2\text{ mol }\text{e}^-/\text{mol }\ce{Cl2}.

  2. Calculate the actual charge required: Qactual=nClX2⋅z⋅Fηcurr=14104 mol×2×96485 C/mol0.950≈2.865×109 CQ_{\text{actual}} = \frac{n_{\ce{Cl2}} \cdot z \cdot F}{\eta_{\text{curr}}} = \frac{14104\text{ mol} \times 2 \times 96485\text{ C/mol}}{0.950} \approx 2.865 \times 10^9\text{ C}.

  3. Calculate the energy consumption in joules: E=Qactual⋅Vcell=2.865×109 C×3.30 V≈9.454×109 JE = Q_{\text{actual}} \cdot V_{\text{cell}} = 2.865 \times 10^9\text{ C} \times 3.30\text{ V} \approx 9.454 \times 10^9\text{ J}.

  4. Convert energy to kilowatt-hours: Specific energy=9.454×109 J3.60×106 J/kWh≈2.63×103 kWh/metric ton ClX2\text{Specific energy} = \frac{9.454 \times 10^9\text{ J}}{3.60 \times 10^6\text{ J/kWh}} \approx 2.63 \times 10^3\text{ kWh/metric ton }\ce{Cl2}.

Final answer

Specific energy consumption=2.63×103 kWh/metric ton ClX2\text{Specific energy consumption} = 2.63 \times 10^3\text{ kWh/metric ton }\ce{Cl2}

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out the explicit balanced electrode half-reaction whenever computing charge with Faraday's law.

  • Verify that the electron stoichiometry factor zz accounts for diatomic and polyatomic product species.

  • Practice calculating specific energy consumption for other electrolytic processes such as water electrolysis and aluminum reduction.

OverviewACEpath Teacher's Diagnosis

02 The student multiplies by the current efficiency instead of dividing by it when calculating actual charge and electrical energy consumption, resulting in an artificially low specific energy consumption.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Vcell=2.20+0.35ln⁡(1+0.80×4.00)+0.15×4.00⟹Vcell=2.20+0.35×1.435+0.60=3.30 VV_{\text{cell}} = 2.20 + 0.35\ln(1 + 0.80 \times 4.00) + 0.15 \times 4.00 \Longrightarrow V_{\text{cell}} = 2.20 + 0.35 \times 1.435 + 0.60 = 3.30\text{ V}

  2. Step 2

    εenergy=2.19×0.9503.30=0.630=63.0%\varepsilon_{\text{energy}} = \frac{2.19 \times 0.950}{3.30} = 0.630 = 63.0\%

  3. Step 3

    n(ClX2)=10670.90=14104 mol⟹Qtheor=2×14104×96485=2.722×109 Cn(\ce{Cl2}) = \frac{10^6}{70.90} = 14104\text{ mol} \Longrightarrow Q_{\text{theor}} = 2 \times 14104 \times 96485 = 2.722 \times 10^9\text{ C}

  4. Step 4

    Qactual=2.722×109×0.950=2.586×109 CQ_{\text{actual}} = 2.722 \times 10^9 \times 0.950 = 2.586 \times 10^9\text{ C}

    Correct

    Qactual=Qtheorηcurr=2.722×109 C0.950≈2.865×109 CQ_{\text{actual}} = \frac{Q_{\text{theor}}}{\eta_{\text{curr}}} = \frac{2.722 \times 10^9\text{ C}}{0.950} \approx 2.865 \times 10^9\text{ C}

    Because unwanted side reactions consume part of the current, an imperfect current efficiency requires passing more total charge than theoretical, not less: Qactual=QtheorηcurrQ_{\text{actual}} = \frac{Q_{\text{theor}}}{\eta_{\text{curr}}}.

  5. Step 5

    Energy=3.30 V×2.586×109 C=8.534×109 J⟹Specific energy=8.534×1093.6×106=2371 kWh/t\text{Energy} = 3.30\text{ V} \times 2.586 \times 10^9\text{ C} = 8.534 \times 10^9\text{ J} \Longrightarrow \text{Specific energy} = \frac{8.534 \times 10^9}{3.6 \times 10^6} = 2371\text{ kWh/t}

    Correct

    Specific energy=Qactual⋅Vcell3.60×106 J/kWh=2.865×109 C×3.30 V3.60×106 J/kWh≈2.63×103 kWh/metric ton\text{Specific energy} = \frac{Q_{\text{actual}} \cdot V_{\text{cell}}}{3.60 \times 10^6\text{ J/kWh}} = \frac{2.865 \times 10^9\text{ C} \times 3.30\text{ V}}{3.60 \times 10^6\text{ J/kWh}} \approx 2.63 \times 10^3\text{ kWh/metric ton}

    Your conversion formula from joules to kilowatt-hours was set up properly, but the result carries over the underestimated value of QactualQ_{\text{actual}} from Step 4.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the cell operating voltage from the empirical current-density equation.

You correctly applied the formula for electrochemical energy efficiency.

You accurately converted metric tons to moles and identified z=2z = 2 electrons per chlorine molecule.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted efficiency factor in charge requirement

Multiplying the theoretical charge by current efficiency instead of dividing by it.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the yield of product from a fixed charge with the charge required to yield a fixed target mass. Current efficiency is defined as η=QusefulQtotal\eta = \frac{Q_{\text{useful}}}{Q_{\text{total}}}; therefore, producing a specified target amount requires Qtotal=Qusefulη>QusefulQ_{\text{total}} = \frac{Q_{\text{useful}}}{\eta} > Q_{\text{useful}}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Sanity check on real-world inputs
  • In any real industrial process where η<1\eta < 1, non-ideal losses mean the actual input resource (charge, energy, raw feed) must exceed the theoretical minimum.

  • Check whether your calculated QactualQ_{\text{actual}} is larger than QtheorQ_{\text{theor}}. If it is smaller, invert the efficiency factor.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Qactual=Qtheorηcurr=2.722×109 C0.950≈2.865×109 CQ_{\text{actual}} = \frac{Q_{\text{theor}}}{\eta_{\text{curr}}} = \frac{2.722 \times 10^9\text{ C}}{0.950} \approx 2.865 \times 10^9\text{ C}

  2. Eactual=Qactual⋅Vcell=2.865×109 C×3.30 V≈9.454×109 JE_{\text{actual}} = Q_{\text{actual}} \cdot V_{\text{cell}} = 2.865 \times 10^9\text{ C} \times 3.30\text{ V} \approx 9.454 \times 10^9\text{ J}

  3. Specific energy consumption=9.454×109 J3.60×106 J/kWh≈2.63×103 kWh/metric ton ClX2\text{Specific energy consumption} = \frac{9.454 \times 10^9\text{ J}}{3.60 \times 10^6\text{ J/kWh}} \approx 2.63 \times 10^3\text{ kWh/metric ton } \ce{Cl2}

Final answer

2.63×103 kWh/metric ton ClX22.63 \times 10^3\text{ kWh/metric ton } \ce{Cl2}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the definition of current (Faradaic) efficiency as ηcurr=mactualmtheor=QtheorQactual\eta_{\text{curr}} = \frac{m_{\text{actual}}}{m_{\text{theor}}} = \frac{Q_{\text{theor}}}{Q_{\text{actual}}}.

  • Practice distinguishing between forward calculations (given II and tt, find mass produced) and target-demand calculations (given target mass, find required charge and energy).

OverviewACEpath Teacher's Diagnosis

03 The student misinterprets natural logarithm ln as common logarithm log₁₀ when evaluating the logarithmic overpotential term in the cell voltage expression.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Vcell=2.20+0.35log⁡10(1+0.80×4.00)+0.15×4.00  ⟹  Vcell=2.20+0.35log⁡10(4.20)+0.60  ⟹  Vcell=2.20+0.35×0.6232+0.60=3.02 VV_{\text{cell}} = 2.20 + 0.35 \log_{10}(1 + 0.80 \times 4.00) + 0.15 \times 4.00 \implies V_{\text{cell}} = 2.20 + 0.35 \log_{10}(4.20) + 0.60 \implies V_{\text{cell}} = 2.20 + 0.35 \times 0.6232 + 0.60 = 3.02\,\text{V}

    Correct

    Vcell=2.20+0.35ln⁡(1+0.80×4.00)+0.15(4.00)=2.20+0.35(1.4351)+0.60≈3.30 VV_{\text{cell}} = 2.20 + 0.35\ln(1 + 0.80 \times 4.00) + 0.15(4.00) = 2.20 + 0.35(1.4351) + 0.60 \approx 3.30\,\text{V}

    You substituted j=4.00 kA/m2j = 4.00\,\text{kA/m}^2 correctly, but you used common logarithm log⁡10(4.20)≈0.6232\log_{10}(4.20) \approx 0.6232 instead of natural logarithm ln⁡(4.20)≈1.4351\ln(4.20) \approx 1.4351.

  2. Step 2

    εenergy=2.19×0.9503.02=0.689=68.9%\varepsilon_{\text{energy}} = \frac{2.19 \times 0.950}{3.02} = 0.689 = 68.9\%

    Correct

    εenergy=2.19×0.9503.30≈0.631=63.1%\varepsilon_{\text{energy}} = \frac{2.19 \times 0.950}{3.30} \approx 0.631 = 63.1\%

    Your formula and substitution logic were completely sound, but your result was affected by the carried-over value of Vcell=3.02 VV_{\text{cell}} = 3.02\,\text{V}.

  3. Step 3

    n(Cl2)=10670.90=14104 mol  ⟹  Q=2×14104×964850.950=2.865×109 C  ⟹  E=3.02 V×2.865×109 C=8.652×109 J  ⟹  Specific energy=8.652×1093.6×106=2403 kWh/tn(\text{Cl}_2) = \frac{10^6}{70.90} = 14104\,\text{mol} \implies Q = \frac{2 \times 14104 \times 96485}{0.950} = 2.865 \times 10^9\,\text{C} \implies E = 3.02\,\text{V} \times 2.865 \times 10^9\,\text{C} = 8.652 \times 10^9\,\text{J} \implies \text{Specific energy} = \frac{8.652 \times 10^9}{3.6 \times 10^6} = 2403\,\text{kWh/t}

    Correct

    E=3.30 V×2.865×109 C=9.454×109 J  ⟹  Specific energy=9.454×109 J3.60×106 J/kWh≈2.63×103 kWh/metric tonE = 3.30\,\text{V} \times 2.865 \times 10^9\,\text{C} = 9.454 \times 10^9\,\text{J} \implies \text{Specific energy} = \frac{9.454 \times 10^9\,\text{J}}{3.60 \times 10^6\,\text{J/kWh}} \approx 2.63 \times 10^3\,\text{kWh/metric ton}

    You correctly determined the stoichiometry (z=2z = 2), total charge QQ, and conversion from joules to kWh\text{kWh}, but your final energy consumption was lower than expected due to carrying forward Vcell=3.02 VV_{\text{cell}} = 3.02\,\text{V}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly identified that z=2 mol e−z = 2\,\text{mol e}^- are transferred per mole of Cl2\text{Cl}_2.

You correctly applied Faraday's law accounting for current efficiency ηcurr=0.950\eta_{\text{curr}} = 0.950.

You converted metric tons to grams and electrical joules to kilowatt-hours with the exact conversion factor 3.60×106 J/kWh3.60 \times 10^6\,\text{J/kWh}.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Logarithm Base Confusion

You evaluated log⁡10(4.20)\log_{10}(4.20) instead of ln⁡(4.20)\ln(4.20) in the empirical Tafel-like overpotential term.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Conflating the natural logarithm (ln⁡\ln, base ee) with the common logarithm (log⁡\log or log⁡10\log_{10}, base 1010), which frequently appears in electrochemical rate expressions.

REASONING PATH
Your ACEpath teacher’s suggested approach
Logarithm Notation Check
  • In electrochemical equations, ln⁡(x)\ln(x) denotes the natural logarithm with base e≈2.718e \approx 2.718, whereas log⁡(x)\log(x) or log⁡10(x)\log_{10}(x) denotes base 1010, differing by a factor of ln⁡(10)≈2.303\ln(10) \approx 2.303.

  • Always verify whether an empirical or kinetic rate term specifies ln⁡\ln or log⁡10\log_{10} before entering values into your calculator.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recompute the cell overpotential term using natural logarithm: 0.35ln⁡(4.20)=0.35×1.4351=0.502 V0.35\ln(4.20) = 0.35 \times 1.4351 = 0.502\,\text{V}.

  2. Add the base and ohmic terms: Vcell=2.20+0.502+0.60=3.302 V≈3.30 VV_{\text{cell}} = 2.20 + 0.502 + 0.60 = 3.302\,\text{V} \approx 3.30\,\text{V}.

  3. Recalculate energy efficiency: εenergy=2.19×0.9503.30≈63.1%\varepsilon_{\text{energy}} = \frac{2.19 \times 0.950}{3.30} \approx 63.1\%.

  4. Recalculate total energy consumed: E=3.30 V×2.865×109 C≈9.454×109 JE = 3.30\,\text{V} \times 2.865 \times 10^9\,\text{C} \approx 9.454 \times 10^9\,\text{J}.

  5. Convert to kWh\text{kWh}: 9.454×109 J3.60×106 J/kWh≈2.63×103 kWh/metric ton Cl2\frac{9.454 \times 10^9\,\text{J}}{3.60 \times 10^6\,\text{J/kWh}} \approx 2.63 \times 10^3\,\text{kWh/metric ton }\text{Cl}_2.

Final answer

(a) Vcell=3.30 VV_{\text{cell}} = 3.30\,\text{V}; (b) εenergy=63.1%\varepsilon_{\text{energy}} = 63.1\%; (c) Specific energy consumption=2.63×103 kWh/metric ton Cl2\text{Specific energy consumption} = 2.63 \times 10^3\,\text{kWh/metric ton }\text{Cl}_2

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check function keys on your calculator to ensure you press the [ln⁡][\ln] key rather than the [log⁡][\log] key when evaluating overpotentials.

  • Practice evaluating Tafel overpotential expressions to build fluency distinguishing natural and base-10 logarithmic forms.

Lock it in

Similar question

01

In an alkaline water electrolysis cell operating at Vcell=1.90 VV_{\text{cell}} = 1.90\text{ V} with a current efficiency of ηcurr=90.0%\eta_{\text{curr}} = 90.0\%, water is split according to 2HX2O→2HX2+OX22\ce{H2O} \rightarrow 2\ce{H2} + \ce{O2}. Calculate the specific electrical energy consumption in kWh/kg\text{kWh/kg} of HX2\ce{H2} produced (molar mass of HX2=2.016 g/mol\ce{H2} = 2.016\text{ g/mol}, F=96485 C/molF = 96485\text{ C/mol}).

Answer

Specific energy =55.7 kWh/kg HX2= 55.7\text{ kWh/kg }\ce{H2}. Steps: For HX2\ce{H2} evolution (2HX2O+2eX−→HX2+2OHX−2\ce{H2O} + 2\ce{e-} \rightarrow \ce{H2} + 2\ce{OH-}), z=2z = 2. Moles per kg: n=1000 g2.016 g/mol≈496.03 moln = \frac{1000\text{ g}}{2.016\text{ g/mol}} \approx 496.03\text{ mol}. Charge: Q=496.03×2×964850.900≈1.0637×108 CQ = \frac{496.03 \times 2 \times 96485}{0.900} \approx 1.0637 \times 10^8\text{ C}. Energy in J\text{J}: E=Q×1.90 V≈2.021×108 JE = Q \times 1.90\text{ V} \approx 2.021 \times 10^8\text{ J}. Specific energy: 2.021×1083.60×106≈55.7 kWh/kg\frac{2.021 \times 10^8}{3.60 \times 10^6} \approx 55.7\text{ kWh/kg}.

02

A chlor-alkali membrane cell operates at a constant current of 150 kA150\text{ kA} and a cell potential of 3.25 V3.25\text{ V}. If the cathode produces NaOH\ce{NaOH} with a current efficiency of 96.0%96.0\%, how many metric tons of pure NaOH\ce{NaOH} (molar mass 40.00 g/mol40.00\text{ g/mol}) are produced in a 24.0-hour24.0\text{-hour} period?

Answer

5.15 metric tons NaOH5.15\text{ metric tons }\ce{NaOH}. Steps: Total actual charge per day: Qtotal=1.50×105 A×(24×3600 s)=1.296×1010 CQ_{\text{total}} = 1.50 \times 10^5\text{ A} \times (24 \times 3600\text{ s}) = 1.296 \times 10^{10}\text{ C}. Effective charge for reaction: Qeff=1.296×1010×0.960=1.244×1010 CQ_{\text{eff}} = 1.296 \times 10^{10} \times 0.960 = 1.244 \times 10^{10}\text{ C}. In the cathode half-reaction (2HX2O+2eX−→HX2+2OHX−2\ce{H2O} + 2\ce{e-} \rightarrow \ce{H2} + 2\ce{OH-}), 1 mole of eX−\ce{e-} produces 1 mole of OHX−\ce{OH-} (thus 1 mole NaOH\ce{NaOH}, so z=1z = 1). Moles of NaOH=1.244×101096485≈1.2895×105 mol\ce{NaOH} = \frac{1.244 \times 10^{10}}{96485} \approx 1.2895 \times 10^5\text{ mol}. Mass: m=1.2895×105 mol×40.00 g/mol≈5.158×106 g≈5.16 metric tonsm = 1.2895 \times 10^5\text{ mol} \times 40.00\text{ g/mol} \approx 5.158 \times 10^6\text{ g} \approx 5.16\text{ metric tons} (or 5.15 t5.15\text{ t} with exact rounding).

03

An industrial copper electrowinning plant deposits pure copper cathode plates from an acidic cupric sulfate solution: CuX2+(aq)+2eX−→Cu(s)\ce{Cu^2+}(aq) + 2\ce{e-} \rightarrow \ce{Cu}(s) at a cell voltage of 2.10 V2.10\text{ V}. Due to parasite parasitic reactions, current efficiency is 88.0%88.0\%. (a) Determine the theoretical minimum thermodynamic energy consumption per metric ton of Cu\ce{Cu} if Ecell∘=0.89 VE^\circ_{\text{cell}} = 0.89\text{ V} (considering the anodic oxygen evolution). (b) Determine the actual specific energy consumption in kWh/metric ton Cu\text{kWh/metric ton }\ce{Cu} (molar mass of Cu=63.55 g/mol\ce{Cu} = 63.55\text{ g/mol}).

Answer

(a) 752 kWh/t752\text{ kWh/t}; (b) 2.02×103 kWh/t2.02 \times 10^3\text{ kWh/t}. Steps: Moles of Cu\ce{Cu} per metric ton: n=106 g63.55 g/mol≈1.5736×104 moln = \frac{10^6\text{ g}}{63.55\text{ g/mol}} \approx 1.5736 \times 10^4\text{ mol}. Since z=2z = 2, theoretical charge Qtheo=1.5736×104×2×96485≈3.0365×109 CQ_{\text{theo}} = 1.5736 \times 10^4 \times 2 \times 96485 \approx 3.0365 \times 10^9\text{ C}. (a) Theoretical energy: Etheo=3.0365×109×0.89 V3.60×106≈750.7 kWh/t≈751–752 kWh/tE_{\text{theo}} = \frac{3.0365 \times 10^9 \times 0.89\text{ V}}{3.60 \times 10^6} \approx 750.7\text{ kWh/t} \approx 751\text{–}752\text{ kWh/t}. (b) Actual charge: Qact=Qtheo0.880≈3.4506×109 CQ_{\text{act}} = \frac{Q_{\text{theo}}}{0.880} \approx 3.4506 \times 10^9\text{ C}. Actual energy: Eact=3.4506×109×2.10 V3.60×106≈2.013×103 kWh/t≈2.01×103–2.02×103 kWh/tE_{\text{act}} = \frac{3.4506 \times 10^9 \times 2.10\text{ V}}{3.60 \times 10^6} \approx 2.013 \times 10^3\text{ kWh/t} \approx 2.01 \times 10^3\text{–}2.02 \times 10^3\text{ kWh/t}.

Loading workspace…