Resources
A physical chemistry lab group tests whether the thermal decomposition of compound follows an elementary unimolecular model or a bimolecular collision model. The group measures the concentration of over time at and constructs two linear regression plots: Model 1 plots versus time (in seconds), yielding with . Model 2 plots (in ) versus time (in seconds), yielding with . Based on the superior linearity of Model 2, calculate the target reaction half-life (in seconds) for an initial concentration of , and determine the percentage error in that would have resulted from mistakenly adopting Model 1 (using ).
Answer and steps
Final answer
Model 2 (second-order kinetics with ) is the correct model based on . The true target half-life is . The erroneous first-order half-life from Model 1 would be . The percentage error is .
Steps
Select the Correct Kinetic Model Based on Linearity
The integrated rate laws for unimolecular (first-order) and bimolecular (second-order) processes are:
- First-order (Model 1):
- Second-order (Model 2):
Comparing the coefficients of determination:
- Model 1 yields .
- Model 2 yields .
Because is much closer to for Model 2, the decomposition of follows second-order kinetics. The slope of the regression line gives the second-order rate constant:
Calculate the True Half-Life Using Model 2
For a second-order reaction, the half-life depends inversely on the initial reactant concentration:
Substitute and :
Calculate the Erroneous Half-Life Using Model 1
If the reaction were incorrectly assumed to be first-order, the half-life would be independent of concentration:
Using the slope from Model 1 ():
Common Pitfall: Assuming first-order kinetics whenever half-life is mentioned. While first-order half-life is constant regardless of initial concentration (), second-order half-life increases as the initial concentration decreases ().
Determine the Percentage Error
The percentage error resulting from choosing Model 1 over the true Model 2 is:
Typical errors
01 The student misremembers the second-order half-life formula as t₁/₂ = [A]₀ / (2k) (the zero-order formula), leading to an incorrect target half-life and incorrect percentage error.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
Model 2 is second order with
- Step 2Correct
You applied the zero-order half-life expression . For a second-order reaction, the half-life is inversely proportional to initial concentration: .
- Step 3
Model 1 gives
- Step 4
Percentage error =
CorrectPercentage error =
Your percentage error formula was set up correctly, but your numerical result was affected by the incorrect value of from Step 2.
WHAT YOU DID WELL
Compliments from Your TeacherYou evaluated the regression values correctly to choose the second-order model.
You extracted the rate constants accurately from the linear regression slopes.
You used the correct first-order half-life formula and percentage error definition.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou recalled instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the integrated rate law half-life relationships across different reaction orders, specifically substituting the zero-order formula (where half-life is directly proportional to initial concentration) for the second-order formula (where half-life is inversely proportional to initial concentration).
REASONING PATH
Your ACEpath teacher’s suggested approach- Half-life concentration dependence
Zero order: ; First order: ; Second order: .
Derive or verify the half-life by setting into the corresponding integrated rate law .
CORRECTED PATH
ACEpath Teacher's DemonstrationSubstitute and into .
.
Compute the percentage error: .
Target , Percentage error =
02 The student normalizes percentage error by the erroneous Model 1 value in the denominator rather than the true Model 2 value.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You placed the erroneous Model 1 value () in the denominator instead of the true accepted Model 2 value ().
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly chose the inverse-concentration half-life formula for the second-order reaction.
You correctly computed both individual half-life values with accurate intermediate rounding.
THE ERROR
Where Your ACEpath Teacher Spotted the Mistakeno
WHY IT HAPPENED
ACEpath Teacher's DiagnosisYou normalized the difference by the incorrect experimental model value rather than the true theoretical benchmark. Percentage error must always be divided by the accepted true reference value.
REASONING PATH
Your ACEpath teacher’s suggested approach- Percentage Error Baseline
Always identify which quantity represents the true benchmark and place only that true value in the denominator.
CORRECTED PATH
ACEpath Teacher's Demonstration;
03 The student omits the initial concentration [A]₀ in the second-order half-life calculation, using t₁/₂ = 1 / k₂.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1Correct
For a second-order reaction, the half-life depends inversely on initial concentration: . Omitting leaves the expression with units of instead of seconds.
- Step 2
- Step 3Correct
Your percentage error formula structure is correct, but your numerical result was affected by the incorrect value of from Step 1.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly selected and interpreted the rate constant values from both regression lines.
You accurately calculated the first-order half-life for Model 1 using .
You correctly set up the relative percentage error formula comparing the two models.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou wrote instead of .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing second-order rate constant dimensions with time or overlooking the concentration dependence of second-order half-life.
REASONING PATH
Your ACEpath teacher’s suggested approach- Check Half-Life Concentration Dependence
Only first-order half-life is independent of initial concentration (). Zero-order is , and second-order is .
Always verify the reaction order before writing down the half-life equation.
- Verify Units via Dimensional Analysis
Half-life must carry units of time (). For a second-order rate constant with units , the reciprocal has units .
Multiply by (in ) in the denominator so that concentration cancels out and yields seconds.
CORRECTED PATH
ACEpath Teacher's DemonstrationCalculate true for Model 2: .
Substitute into the percentage error formula: .
True ; Percentage error
Lock it in
What is the half-life () formula for a second-order reaction with rate constant and initial concentration ?
. Memory cue: In second-order kinetics, higher concentration speeds up collisions, making the half-life shorter (inverse dependence).
Similar question
A dimerization reaction follows second-order kinetics with . If the initial concentration of monomer is , calculate the time required for half of the monomer to react.
Answer
.
The decomposition of is second order with at . Compare the first half-life () to the second half-life (time from to ).
Answer
First half-life: . Second half-life starts at : . The second half-life is exactly double the first.
An experiment yields linear data for both vs (, slope ) and vs (, slope ). For , determine the true half-life and the percentage error if the first-order fit had been used.
Answer
True model is second order (): . Erroneous first-order: . Percentage error: .