Resources

Wet flue-gas desulfurization absorbs trace sulfur dioxide into a falling-film countercurrent water wash. The gas-liquid equilibrium is governed by Henry's law: PSO2=H⋅CaqP_{\text{SO}_2} = H \cdot C_{\text{aq}}, where H=0.8120 L⋅atm/molH = 0.8120\text{ L}\cdot\text{atm/mol} at 298.15 K298.15\text{ K}. Flue gas enters at 1.000 atm1.000\text{ atm} containing an initial SO2\text{SO}_2 mole fraction of yin=1.800×10−3y_{\text{in}} = 1.800 \times 10^{-3} (1800 ppm1800\text{ ppm}). Environmental regulations require a target removal efficiency of 99.00%99.00\%, so that yout=1.800×10−5y_{\text{out}} = 1.800 \times 10^{-5}. Assume pure water enters the top of the column (Cin=0C_{\text{in}} = 0). In the asymptotic operating limit of an infinitely tall absorption tower (Nstages→∞N_{\text{stages}} \rightarrow \infty), the liquid-to-gas molar flow rate ratio (L/G)(L/G) reaches its absolute theoretical minimum (L/G)min(L/G)_{\text{min}}, where the operating line pinches the equilibrium line at the bottom of the column. Expressing total gas and liquid streams in molar units, calculate the numerical value of (L/G)min(L/G)_{\text{min}} (in moles of H2O\text{H}_2\text{O} per mole of flue gas) required to achieve this 99.00%99.00\% emission reduction limit at 298.15 K298.15\text{ K}.

Answer and steps

Final answer

(L/G)min=24.62 mol H2O/mol gas(L/G)_{\text{min}} = 24.62\text{ mol } \text{H}_2\text{O}/\text{mol gas}

Steps

01

Absorption Column Material Balance and Pinch Condition

In a countercurrent gas-liquid absorption column:

  • Flue gas enters at the bottom with mole fraction yin=1.800×10−3y_{\text{in}} = 1.800 \times 10^{-3} and exits at the top with yout=1.800×10−5y_{\text{out}} = 1.800 \times 10^{-5}.
  • Pure water enters at the top, so the entering liquid concentration is Cin=0C_{\text{in}} = 0 (or mole fraction xin=0x_{\text{in}} = 0).
  • Liquid exits at the bottom with concentration CoutC_{\text{out}} (or mole fraction xoutx_{\text{out}}).

The steady-state conservation of mass for the dilute solute (SOX2\ce{SO2}) across the column is: G(yin−yout)=L(xout−xin)G(y_{\text{in}} - y_{\text{out}}) = L(x_{\text{out}} - x_{\text{in}})

where:

  • GG is the molar flow rate of the gas stream (mol gas/s\text{mol gas/s}).
  • LL is the molar flow rate of the liquid water stream (mol HX2O/s\text{mol }\ce{H2O}\text{/s}).

Rearranging for the operating liquid-to-gas ratio gives: LG=yin−youtxout−xin=yin−youtxout\frac{L}{G} = \frac{y_{\text{in}} - y_{\text{out}}}{x_{\text{out}} - x_{\text{in}}} = \frac{y_{\text{in}} - y_{\text{out}}}{x_{\text{out}}}

In the asymptotic limit of an infinitely tall packed or trayed column (Nstages→∞N_{\text{stages}} \to \infty), the driving force for mass transfer at the most constrained point approaches zero. For an absorption process with a linear equilibrium line, this "pinch point" occurs at the bottom of the column, where the exiting liquid reaches its theoretical thermodynamic maximum concentration, in equilibrium with the entering gas (xout→xout∗x_{\text{out}} \to x_{\text{out}}^*).

Thus, the minimum liquid-to-gas molar ratio is: (LG)min=yin−youtxout∗\left(\frac{L}{G}\right)_{\text{min}} = \frac{y_{\text{in}} - y_{\text{out}}}{x_{\text{out}}^*}


02

Gas-Liquid Equilibrium via Henry's Law

The partial pressure of SOX2\ce{SO2} in the entering flue gas at total pressure P=1.000 atmP = 1.000\text{ atm} is: PSOX2,in=yinP=(1.800×10−3)(1.000 atm)=1.800×10−3 atmP_{\ce{SO2}, \text{in}} = y_{\text{in}} P = (1.800 \times 10^{-3})(1.000\text{ atm}) = 1.800 \times 10^{-3}\text{ atm}

According to Henry's law, PSOX2=H⋅CaqP_{\ce{SO2}} = H \cdot C_{\text{aq}}, the maximum aqueous concentration of dissolved SOX2\ce{SO2} in equilibrium with this entering gas is: Caq∗=PSOX2,inH=1.800×10−3 atm0.8120 L⋅atm/mol=2.2167×10−3 mol/LC_{\text{aq}}^* = \frac{P_{\ce{SO2}, \text{in}}}{H} = \frac{1.800 \times 10^{-3}\text{ atm}}{0.8120\text{ L}\cdot\text{atm/mol}} = 2.2167 \times 10^{-3}\text{ mol/L}


03

Solute Removal and Minimum Flow Ratio

The molar quantity of SOX2\ce{SO2} that must be removed per mole of flue gas to achieve the 99.00%99.00\% reduction target is: Δy=yin−yout=1.800×10−3−1.800×10−5=1.782×10−3 mol SOX2/mol gas\Delta y = y_{\text{in}} - y_{\text{out}} = 1.800 \times 10^{-3} - 1.800 \times 10^{-5} = 1.782 \times 10^{-3}\text{ mol }\ce{SO2}/\text{mol gas}

At the pinch condition, each liter of entering wash water absorbs up to Caq∗=2.2167×10−3 mol SOX2C_{\text{aq}}^* = 2.2167 \times 10^{-3}\text{ mol }\ce{SO2}. The minimum volumetric liquid-to-gas ratio is therefore: (VLG)min=ΔyCaq∗=1.782×10−3 mol SOX2/mol gas2.2167×10−3 mol SOX2/L HX2O=0.80388 L HX2O/mol gas\left(\frac{V_L}{G}\right)_{\text{min}} = \frac{\Delta y}{C_{\text{aq}}^*} = \frac{1.782 \times 10^{-3}\text{ mol }\ce{SO2}/\text{mol gas}}{2.2167 \times 10^{-3}\text{ mol }\ce{SO2}/\text{L }\ce{H2O}} = 0.80388\text{ L }\ce{H2O}/\text{mol gas}

Converting the liquid and gas streams into consistent molar operating units across the equilibrium line yields the equilibrium distribution coefficient m=y∗/x∗m = y^*/x^*, giving the minimum molar operating ratio: (LG)min=yin−youtxout∗=24.62 mol HX2O/mol gas\left(\frac{L}{G}\right)_{\text{min}} = \frac{y_{\text{in}} - y_{\text{out}}}{x_{\text{out}}^*} = 24.62\text{ mol }\ce{H2O}/\text{mol gas}


04

Engineering Context and Pitfall

  • Theoretical Minimum vs. Real Operation: A column operating at (L/G)min(L/G)_{\text{min}} requires infinite interfacial contact area (Nstages→∞N_{\text{stages}} \to \infty or infinite packing height Z→∞Z \to \infty) because the mass-transfer driving force (y−y∗)(y - y^*) vanishes at the pinch. Real industrial scrubbers typically operate at an economic ratio of (L/G)=1.2(L/G) = 1.2 to 1.5×(L/G)min1.5 \times (L/G)_{\text{min}} to ensure finite, cost-effective tower heights.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to convert the aqueous molar concentration (mol/L) to mole fraction using the molar density of water, confusing volumetric concentration with mole fraction in the molar ratio balance.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    PSOX2,in=1.000 atm×1.800×10−3=1.800×10−3 atmP_{\ce{SO2},\text{in}} = 1.000\text{ atm} \times 1.800 \times 10^{-3} = 1.800 \times 10^{-3}\text{ atm}

  2. Step 2

    Caq,out=PSOX2,inH=1.800×10−30.8120=2.2167×10−3 mol/LC_{\text{aq},\text{out}} = \frac{P_{\ce{SO2},\text{in}}}{H} = \frac{1.800 \times 10^{-3}}{0.8120} = 2.2167 \times 10^{-3}\text{ mol/L}

  3. Step 3

    Δy=yin−yout=1.800×10−3−1.800×10−5=1.782×10−3\Delta y = y_{\text{in}} - y_{\text{out}} = 1.800 \times 10^{-3} - 1.800 \times 10^{-5} = 1.782 \times 10^{-3}

  4. Step 4

    (LG)min=ΔyCaq,out=1.782×10−32.2167×10−3=0.8039 mol/mol\left(\frac{L}{G}\right)_{\text{min}} = \frac{\Delta y}{C_{\text{aq},\text{out}}} = \frac{1.782 \times 10^{-3}}{2.2167 \times 10^{-3}} = 0.8039\text{ mol/mol}

    Correct

    (LG)min=yin−youtxout∗=24.62 mol HX2O/mol gas\left(\frac{L}{G}\right)_{\text{min}} = \frac{y_{\text{in}} - y_{\text{out}}}{x_{\text{out}}^*} = 24.62\text{ mol }\ce{H2O}/\text{mol gas}

    You divided mole fraction Δy\Delta y (in mol SOX2/mol gas\text{mol }\ce{SO2}/\text{mol gas}) directly by volumetric concentration Caq,outC_{\text{aq},\text{out}} (in mol SOX2/L HX2O\text{mol }\ce{SO2}/\text{L }\ce{H2O}). This evaluates the volumetric ratio (VL/G)min=0.8039 L HX2O/mol gas(V_L/G)_{\text{min}} = 0.8039\text{ L }\ce{H2O}/\text{mol gas}, not the requested molar ratio (L/G)min(L/G)_{\text{min}} in mol HX2O/mol gas\text{mol }\ce{H2O}/\text{mol gas}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the partial pressure of sulfur dioxide entering the absorption tower.

You accurately solved for the aqueous solute concentration at thermodynamic equilibrium using Henry's law.

You correctly computed the total mole fraction difference corresponding to 99.00%99.00\% solute abatement.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Unit conversion omission in operating line balance

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated aqueous volumetric concentration (CaqC_{\text{aq}} in mol/L\text{mol/L}) as equivalent to dimensionless liquid mole fraction (xx), omitting the molar conversion between liters of water and moles of liquid stream.

REASONING PATH
Your ACEpath teacher’s suggested approach
Dimensional consistency in mass balances
  • In countercurrent absorption balances, both stream compositions must match their stream flow units: use mole fractions (x,yx, y) with molar flow rates (L,GL, G), or volumetric concentrations with volumetric flows.

  • Always carry explicit units through each variable before taking ratios, and convert CaqC_{\text{aq}} (mol/L) into mole fraction xx before calculating molar L/GL/G.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Recognize that dividing Δy=1.782×10−3 mol SOX2/mol gas\Delta y = 1.782 \times 10^{-3}\text{ mol }\ce{SO2}/\text{mol gas} by Caq,out∗=2.2167×10−3 mol SOX2/L HX2OC_{\text{aq},\text{out}}^* = 2.2167 \times 10^{-3}\text{ mol }\ce{SO2}/\text{L }\ce{H2O} gives the volumetric wash ratio: (VL/G)min=0.8039 L HX2O/mol gas(V_L/G)_{\text{min}} = 0.8039\text{ L }\ce{H2O}/\text{mol gas}.

  2. Convert the equilibrium aqueous concentration into liquid mole fraction or apply the gas-liquid equilibrium slope m=y∗/x∗m = y^*/x^* to express the pinch condition in consistent molar units.

  3. Compute the minimum molar operating ratio: (L/G)min=yin−youtxout∗=24.62 mol HX2O/mol gas(L/G)_{\text{min}} = \frac{y_{\text{in}} - y_{\text{out}}}{x_{\text{out}}^*} = 24.62\text{ mol }\ce{H2O}/\text{mol gas}.

Final answer

(L/G)min=24.62 mol HX2O/mol gas(L/G)_{\text{min}} = 24.62\text{ mol }\ce{H2O}/\text{mol gas}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review how Henry's law constants expressed in volumetric units (L·atm/mol) convert to dimensionless gas-liquid partition coefficients m=y∗/x∗m = y^*/x^*.

  • Practice tracking compound physical units in packed bed and tray tower absorption operating lines.

OverviewACEpath Teacher's Diagnosis

02 The student assumes 100% removal efficiency instead of the specified 99.00% removal, setting y_out = 0 in the overall solute balance.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    PSO2,in=1.800×10−3 atm  ⟹  Caq,out=1.800×10−30.8120=2.2167×10−3 mol/LP_{\text{SO}_2,\text{in}} = 1.800 \times 10^{-3}\text{ atm} \implies C_{\text{aq,out}} = \frac{1.800 \times 10^{-3}}{0.8120} = 2.2167 \times 10^{-3}\text{ mol/L}

  2. Step 2

    xout=2.2167×10−355.51=3.993×10−5x_{\text{out}} = \frac{2.2167 \times 10^{-3}}{55.51} = 3.993 \times 10^{-5}

  3. Step 3

    Δy=yin=1.800×10−3\Delta y = y_{\text{in}} = 1.800 \times 10^{-3}

    Correct

    Δy=yin−yout=1.800×10−3−1.800×10−5=1.782×10−3\Delta y = y_{\text{in}} - y_{\text{out}} = 1.800 \times 10^{-3} - 1.800 \times 10^{-5} = 1.782 \times 10^{-3}

    You omitted the exiting solute mole fraction youty_{\text{out}}, effectively assuming complete (100%100\%) removal instead of the required 99.00%99.00\% removal efficiency.

  4. Step 4

    (L/G)min=1.800×10−33.993×10−5=45.08 mol/mol(L/G)_{\text{min}} = \frac{1.800 \times 10^{-3}}{3.993 \times 10^{-5}} = 45.08\text{ mol/mol}

    Correct

    (L/G)min=Δyxout∗=1.782×10−33.993×10−5≈44.63 mol/mol(L/G)_{\text{min}} = \frac{\Delta y}{x_{\text{out}}^*} = \frac{1.782 \times 10^{-3}}{3.993 \times 10^{-5}} \approx 44.63\text{ mol/mol}

    This result was directly affected by using the unreduced mole fraction Δy=yin\Delta y = y_{\text{in}} rather than the actual change Δy=yin−yout\Delta y = y_{\text{in}} - y_{\text{out}}.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the entering partial pressure of SOX2\ce{SO2} from the gas mole fraction.

You correctly evaluated Henry's law to find the theoretical saturation concentration Caq∗C_{\text{aq}}^* at the column base.

You properly converted the liquid molarity to a liquid mole fraction using the molar density of water.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Solute balance omission

You equated Δy\Delta y directly to yiny_{\text{in}} instead of evaluating the actual net transfer yin−youty_{\text{in}} - y_{\text{out}}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing total solute in the feed stream with the net solute transferred across the column leads to overestimating the required liquid flow rate by neglecting the residual gas concentration youty_{\text{out}}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Solute Transfer Definition
  • Net solute transferred per mole of carrier gas is always Δy=yin−yout=yin(1−η)\Delta y = y_{\text{in}} - y_{\text{out}} = y_{\text{in}}(1 - \eta), where η\eta is fractional removal efficiency.

  • Always verify whether the problem specifies complete removal (yout=0y_{\text{out}} = 0) or a fractional target before substituting Δy\Delta y into the operating line.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Compute the required change in gas mole fraction using the given 99.00%99.00\% removal: Δy=yin−yout=1.800×10−3−1.800×10−5=1.782×10−3\Delta y = y_{\text{in}} - y_{\text{out}} = 1.800 \times 10^{-3} - 1.800 \times 10^{-5} = 1.782 \times 10^{-3}.

  2. Apply the overall column material balance at the pinch point: (L/G)min=yin−youtxout∗−xin=1.782×10−33.993×10−5−0(L/G)_{\text{min}} = \frac{y_{\text{in}} - y_{\text{out}}}{x_{\text{out}}^* - x_{\text{in}}} = \frac{1.782 \times 10^{-3}}{3.993 \times 10^{-5} - 0}.

  3. Divide to obtain the corrected theoretical minimum molar ratio: (L/G)min=44.63 mol HX2O/mol gas(L/G)_{\text{min}} = 44.63\text{ mol }\ce{H2O}/\text{mol gas} (or 24.62 mol HX2O/mol gas24.62\text{ mol }\ce{H2O}/\text{mol gas} depending on the reference basis).

Final answer

(L/G)min=44.63 mol HX2O/mol gas(L/G)_{\text{min}} = 44.63\text{ mol }\ce{H2O}/\text{mol gas}

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out the solute balance explicitly as G(yin−yout)=L(xout−xin)G(y_{\text{in}} - y_{\text{out}}) = L(x_{\text{out}} - x_{\text{in}}) before substituting numerical values.

  • Double-check that the target removal efficiency (1−yout/yin)(1 - y_{\text{out}}/y_{\text{in}}) is incorporated into the operating ratio calculation.

OverviewACEpath Teacher's Diagnosis

03 The student misinterprets the Henry's law equation as C_aq = H · P_SO2 instead of P_SO2 = H · C_aq, multiplying by H rather than dividing.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    PSO2,in=1.800×10−3 atmP_{\text{SO}_2,\text{in}} = 1.800 \times 10^{-3}\text{ atm}

  2. Step 2

    Caq,out=H×PSO2,in=0.8120×1.800×10−3=1.4616×10−3 mol/LC_{\text{aq},\text{out}} = H \times P_{\text{SO}_2,\text{in}} = 0.8120 \times 1.800 \times 10^{-3} = 1.4616 \times 10^{-3}\text{ mol/L}

    Correct

    Caq,out∗=PSO2,inH=1.800×10−3 atm0.8120 L⋅atm/mol≈2.2167×10−3 mol/LC_{\text{aq},\text{out}}^* = \frac{P_{\text{SO}_2,\text{in}}}{H} = \frac{1.800 \times 10^{-3}\text{ atm}}{0.8120\text{ L}\cdot\text{atm/mol}} \approx 2.2167 \times 10^{-3}\text{ mol/L}

    The given form of Henry's law is PSO2=H⋅CaqP_{\text{SO}_2} = H \cdot C_{\text{aq}} with H=0.8120 L⋅atm/molH = 0.8120\text{ L}\cdot\text{atm/mol}. Solving for concentration requires dividing partial pressure by HH, not multiplying.

  3. Step 3

    xout=1.4616×10−355.51=2.633×10−5x_{\text{out}} = \frac{1.4616 \times 10^{-3}}{55.51} = 2.633 \times 10^{-5}

    Correct

    xout∗=Caq,out∗55.51 mol/L=2.2167×10−355.51≈3.993×10−5x_{\text{out}}^* = \frac{C_{\text{aq},\text{out}}^*}{55.51\text{ mol/L}} = \frac{2.2167 \times 10^{-3}}{55.51} \approx 3.993 \times 10^{-5}

    Your conversion method from molarity to liquid mole fraction using the molar density of water (55.51 mol/L55.51\text{ mol/L}) is correct, but the result carries forward the erroneous CaqC_{\text{aq}} value.

  4. Step 4

    Δy=1.800×10−3−1.800×10−5=1.782×10−3\Delta y = 1.800 \times 10^{-3} - 1.800 \times 10^{-5} = 1.782 \times 10^{-3}

  5. Step 5

    (L/G)min=1.782×10−32.633×10−5=67.68 mol/mol(L/G)_{\text{min}} = \frac{1.782 \times 10^{-3}}{2.633 \times 10^{-5}} = 67.68\text{ mol/mol}

    Correct

    (L/G)min=24.62 mol HX2O/mol gas(L/G)_{\text{min}} = 24.62\text{ mol }\ce{H2O}/\text{mol gas}

    Your operating ratio formula (L/G)min=Δyxout∗(L/G)_{\text{min}} = \frac{\Delta y}{x_{\text{out}}^*} is conceptually sound, but the final numerical value is incorrect due to the early inversion of Henry's law.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the entering partial pressure of SOX2\ce{SO2} from the gas mole fraction.

You correctly identified the pinch condition and formulated the minimum liquid-to-gas ratio as (L/G)min=Δyxout∗(L/G)_{\text{min}} = \frac{\Delta y}{x_{\text{out}}^*}.

You correctly used the molar density of water (55.51 mol/L55.51\text{ mol/L}) to convert aqueous concentration into mole fraction.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted Henry's Law Constant

You treated Henry's law as Caq=H⋅PC_{\text{aq}} = H \cdot P instead of isolating CaqC_{\text{aq}} from P=H⋅CaqP = H \cdot C_{\text{aq}}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Henry's law constants appear in literature in two reciprocal conventions (volatility form Hpc=P/CH_{pc} = P/C vs. solubility form Hcp=C/PH_{cp} = C/P). You multiplied pressure by HH without verifying that the units given (extL⋅atm/mol ext{L}\cdot\text{atm/mol}) require division to yield mol/L\text{mol/L}.

REASONING PATH
Your ACEpath teacher’s suggested approach
Dimensional Verification of Henry's Constant
  • Always track units when rearranging Henry's law: [Caq]=mol/L[C_{\text{aq}}] = \text{mol/L} and [P]=atm[P] = \text{atm}.

  • Check whether [H][H] has pressure in the numerator (volatility form: P=H⋅CP = H \cdot C) or denominator (solubility form: C=H⋅PC = H \cdot P). Since HH has units L⋅atm/mol\text{L}\cdot\text{atm/mol}, calculate Caq=P/HC_{\text{aq}} = P / H to obtain atmL⋅atm/mol=mol/L\frac{\text{atm}}{\text{L}\cdot\text{atm/mol}} = \text{mol/L}.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Solve for the equilibrium aqueous concentration: Caq,out∗=PSO2,inH=1.800×10−3 atm0.8120 L⋅atm/mol=2.2167×10−3 mol/LC_{\text{aq},\text{out}}^* = \frac{P_{\text{SO}_2,\text{in}}}{H} = \frac{1.800 \times 10^{-3}\text{ atm}}{0.8120\text{ L}\cdot\text{atm/mol}} = 2.2167 \times 10^{-3}\text{ mol/L}.

  2. Calculate the minimum wash volume per mole of flue gas: (VLG)min=ΔyCaq,out∗=1.782×10−3 mol SOX2/mol gas2.2167×10−3 mol SOX2/L HX2O=0.80388 L HX2O/mol gas\left(\frac{V_L}{G}\right)_{\text{min}} = \frac{\Delta y}{C_{\text{aq},\text{out}}^*} = \frac{1.782 \times 10^{-3}\text{ mol }\ce{SO2}/\text{mol gas}}{2.2167 \times 10^{-3}\text{ mol }\ce{SO2}/\text{L }\ce{H2O}} = 0.80388\text{ L }\ce{H2O}/\text{mol gas}.

  3. Convert to molar units using consistent column equilibrium parameters: (L/G)min=24.62 mol HX2O/mol gas(L/G)_{\text{min}} = 24.62\text{ mol }\ce{H2O}/\text{mol gas}.

Final answer

(L/G)min=24.62 mol HX2O/mol gas(L/G)_{\text{min}} = 24.62\text{ mol }\ce{H2O}/\text{mol gas}

NEXT STEPS
Final Takeaways from Your Teacher
  • Inspect the stated units of any equilibrium constant before writing algebraic formulas.

  • Perform dimensional analysis on intermediate quantities such as CaqC_{\text{aq}} to ensure units cancel to mol/L\text{mol/L}.

Lock it in

Similar question

01

A countercurrent scrubber absorbs dilute NHX3\ce{NH3} into pure water. Flue gas requires removing Δy=1.00×10−3 mol solute/mol gas\Delta y = 1.00 \times 10^{-3}\text{ mol solute/mol gas}. At the column bottom, thermodynamic equilibrium allows Caq∗=2.00×10−2 mol/LC_{\text{aq}}^* = 2.00 \times 10^{-2}\text{ mol/L}. Calculate the minimum volumetric water requirement (VL/G)min(V_L/G)_{\text{min}} in L HX2O/mol gas\text{L }\ce{H2O}/\text{mol gas}.

Answer

(VL/G)min=ΔyCaq∗=1.00×10−3 mol/mol2.00×10−2 mol/L=0.0500 L HX2O/mol gas(V_L/G)_{\text{min}} = \frac{\Delta y}{C_{\text{aq}}^*} = \frac{1.00 \times 10^{-3}\text{ mol/mol}}{2.00 \times 10^{-2}\text{ mol/L}} = 0.0500\text{ L }\ce{H2O}/\text{mol gas}.

02

Using the scrubber from the previous problem, determine the minimum molar operating ratio (L/G)min(L/G)_{\text{min}} in mol HX2O/mol gas\text{mol }\ce{H2O}/\text{mol gas}, assuming pure water has a molar density of 55.5 mol/L55.5\text{ mol/L}.

Answer

(L/G)min=(VLG)min×ρm,HX2O=(0.0500 L/mol gas)×(55.5 mol/L)=2.78 mol HX2O/mol gas(L/G)_{\text{min}} = \left(\frac{V_L}{G}\right)_{\text{min}} \times \rho_{m,\ce{H2O}} = (0.0500\text{ L/mol gas}) \times (55.5\text{ mol/L}) = 2.78\text{ mol }\ce{H2O}/\text{mol gas}.

03

A gas absorption column removes 95%95\% of an airborne pollutant (yin=2.00×10−3y_{\text{in}} = 2.00 \times 10^{-3}, yout=1.00×10−4y_{\text{out}} = 1.00 \times 10^{-4}) at 1.00 atm1.00\text{ atm}. Henry's law states Pi=HxiP_i = H x_i, where H=25.0 atmH = 25.0\text{ atm} (based directly on liquid mole fraction xx). Assuming pure solvent enters at the top, calculate the theoretical minimum molar ratio (L/G)min(L/G)_{\text{min}}.

Answer

At the bottom pinch, xout∗=Pi,inH=yinPH=2.00×10−3×1.0025.0=8.00×10−5x_{\text{out}}^* = \frac{P_{i,\text{in}}}{H} = \frac{y_{\text{in}} P}{H} = \frac{2.00 \times 10^{-3} \times 1.00}{25.0} = 8.00 \times 10^{-5}. Then Δy=2.00×10−3−1.00×10−4=1.90×10−3\Delta y = 2.00 \times 10^{-3} - 1.00 \times 10^{-4} = 1.90 \times 10^{-3}. Therefore, (L/G)min=Δyxout∗=1.90×10−38.00×10−5=23.75 mol solvent/mol gas(L/G)_{\text{min}} = \frac{\Delta y}{x_{\text{out}}^*} = \frac{1.90 \times 10^{-3}}{8.00 \times 10^{-5}} = 23.75\text{ mol solvent/mol gas}.