Resources

In a shallow, temperate freshwater wetland, high-density residential developments install artificial phosphorus-retention settling basins. A regional watershed model assumes that reducing external anthropogenic phosphorus loading by 60.0%60.0\% will immediately suppress invasive submerged macrophytes and restore native benthic charophyte algal beds. However, decades of prior untreated agricultural runoff enriched the wetland sediment with an exchangeable iron-bound phosphorus pool of 4.80×103 kg P4.80 \times 10^3\text{ kg P}. Under summer thermal stratification, the hypolimnion becomes anoxic (DO<0.50 mg/L\text{DO} < 0.50\text{ mg/L}), triggering the reductive dissolution of ferric iron (Fe3+\text{Fe}^{3+} to Fe2+\text{Fe}^{2+}) and releasing mobile phosphate into the water column at an internal benthic flux rate of 18.5 mg P/m2⋅day18.5\text{ mg P/m}^2\cdot\text{day} across a 2.00×105 m22.00 \times 10^5\text{ m}^2 basin area. If the wetland volume is 6.00×105 m36.00 \times 10^5\text{ m}^3 and the external post-mitigation tributary inflow contributes an additional 1.30 kg P/day1.30\text{ kg P/day}, calculate the total effective daily phosphorus load entering the wetland water column during anoxic periods in kg P/day\text{kg P/day}, and calculate the resulting steady-state phosphorus accumulation rate in  μg/L⋅day\,\mu\mathrm{g/L}\cdot\text{day} (assuming negligible surface outflow during mid-summer).

Answer and steps

Final answer

Total load=5.00 kg P/day; Accumulation rate=8.33 μg/L⋅day\text{Total load} = 5.00\text{ kg P/day};\text{ Accumulation rate} = 8.33\,\mu\mathrm{g/L}\cdot\text{day}

Steps

01

Calculate the internal phosphorus loading from the sediment

During periods of summer thermal stratification, oxygen depletion in the bottom water (hypolimnion) reduces insoluble ferric iron compounds (FeX3+\ce{Fe^{3+}}) to soluble ferrous iron (FeX2+\ce{Fe^{2+}}), releasing trapped orthophosphate into the water column (internal loading).

Multiply the internal flux rate by the total benthic area:

Internal daily flux=18.5 mg P/(m2⋅day)×(2.00×105 m2)=3.70×106 mg P/day\text{Internal daily flux} = 18.5\text{ mg P/(m}^2\cdot\text{day)} \times (2.00 \times 10^5\text{ m}^2) = 3.70 \times 10^6\text{ mg P/day}

Convert milligrams (mg\text{mg}) to kilograms (kg\text{kg}), where 1 kg=106 mg1\text{ kg} = 10^6\text{ mg}:

Lint=3.70×106 mg P/day106 mg/kg=3.70 kg P/dayL_{\text{int}} = \frac{3.70 \times 10^6\text{ mg P/day}}{10^6\text{ mg/kg}} = 3.70\text{ kg P/day}


02

Determine the total daily phosphorus load entering the wetland

The total daily phosphorus input during anoxic periods is the sum of the external tributary loading and the internal benthic release:

Ltotal=Lext+LintL_{\text{total}} = L_{\text{ext}} + L_{\text{int}}

Ltotal=1.30 kg P/day+3.70 kg P/day=5.00 kg P/dayL_{\text{total}} = 1.30\text{ kg P/day} + 3.70\text{ kg P/day} = 5.00\text{ kg P/day}


03

Calculate the phosphorus accumulation rate in the water column

Because there is negligible surface outflow during mid-summer, all introduced phosphorus remains in the wetland water volume.

  1. Convert the wetland volume to liters (L\text{L}): V=6.00×105 m3×1000 L/m3=6.00×108 LV = 6.00 \times 10^5\text{ m}^3 \times 1000\text{ L/m}^3 = 6.00 \times 10^8\text{ L}
  2. Convert the daily phosphorus load to micrograms (μg\mu\text{g}): 1 kg=109 μg1\text{ kg} = 10^9\text{ }\mu\text{g} Ltotal=5.00 kg/day×109 μg/kg=5.00×109 μg/dayL_{\text{total}} = 5.00\text{ kg/day} \times 10^9\text{ }\mu\text{g/kg} = 5.00 \times 10^9\text{ }\mu\text{g/day}
  3. Compute the volumetric accumulation rate: Accumulation rate=LtotalV=5.00×109 μg P/day6.00×108 L=506 μg/(L⋅day)≈8.33 μg/L⋅day\text{Accumulation rate} = \frac{L_{\text{total}}}{V} = \frac{5.00 \times 10^9\text{ }\mu\text{g P/day}}{6.00 \times 10^8\text{ L}} = \frac{50}{6}\text{ }\mu\text{g/(L}\cdot\text{day)} \approx 8.33\text{ }\mu\text{g/L}\cdot\text{day}

Pitfall Note: Reducing external runoff alone does not immediately restore eutrophic water bodies when a large "legacy phosphorus" pool exists in the sediments; hypoxia sustains high internal nutrient cycling independently of watershed management.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to account for internal benthic release from sediment anoxia and uses only the external tributary load.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Total daily load=external load=1.30 kg P/day\text{Total daily load} = \text{external load} = 1.30\text{ kg P/day}

    Correct

    Ltotal=Lext+Lint=1.30 kg P/day+(18.5 mg/(m2⋅day)×2.00×105 m2×10−6 kg/mg)=5.00 kg P/dayL_{\text{total}} = L_{\text{ext}} + L_{\text{int}} = 1.30\text{ kg P/day} + (18.5\text{ mg/(m}^2\cdot\text{day)} \times 2.00 \times 10^5\text{ m}^2 \times 10^{-6}\text{ kg/mg}) = 5.00\text{ kg P/day}

    You set the total phosphorus load equal to the external tributary load alone, omitting the internal loading released from the sediment bed under anoxic conditions.

  2. Step 2

    Volume=6.00×105 m3=6.00×108 L\text{Volume} = 6.00 \times 10^5\text{ m}^3 = 6.00 \times 10^8\text{ L}

  3. Step 3

    Load=1.30 kg P/day=1.30×109 μg P/day  ⟹  Accumulation rate=1.30×109 μg/day6.00×108 L=2.17 μg/(L⋅day)\text{Load} = 1.30\text{ kg P/day} = 1.30 \times 10^9\text{ }\mu\text{g P/day} \implies \text{Accumulation rate} = \frac{1.30 \times 10^9\text{ }\mu\text{g/day}}{6.00 \times 10^8\text{ L}} = 2.17\text{ }\mu\text{g/(L}\cdot\text{day)}

    Correct

    Accumulation rate=5.00×109 μg/day6.00×108 L≈8.33 μg/(L⋅day)\text{Accumulation rate} = \frac{5.00 \times 10^9\text{ }\mu\text{g/day}}{6.00 \times 10^8\text{ L}} \approx 8.33\text{ }\mu\text{g/(L}\cdot\text{day)}

    Your conversion from kilograms to micrograms and your division by volume were carried out accurately, but the numerical result was thrown off by the missing internal load.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted cubic meters to liters using the factor of 1000 L/m31000\text{ L/m}^3.

You correctly converted kilograms of phosphorus to micrograms using the factor of 109 μg/kg10^9\text{ }\mu\text{g/kg}.

You correctly set up the volumetric accumulation rate as total load divided by wetland volume.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of internal sediment nutrient flux

You treated the external tributary input as the entire phosphorus source, overlooking the internal flux generated across the benthic area.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You focused exclusively on external watershed inputs and missed that legacy phosphorus in aquatic sediments is remobilized under hypolimnetic anoxia, functioning as a major internal source that must be added to external loads.

REASONING PATH
Your ACEpath teacher’s suggested approach
Account for Internal Nutrient Fluxes
  • Ltotal=Lexternal+(Benthic Flux Rate×Benthic Area)L_{\text{total}} = L_{\text{external}} + (\text{Benthic Flux Rate} \times \text{Benthic Area})

  • Check whether anoxia or redox conditions trigger internal sediment release, and multiply the area-specific flux by total basin area before adding it to external loading.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate internal loading: Lint=18.5 mg P/(m2⋅day)×2.00×105 m2=3.70×106 mg P/day=3.70 kg P/dayL_{\text{int}} = 18.5\text{ mg P/(m}^2\cdot\text{day)} \times 2.00 \times 10^5\text{ m}^2 = 3.70 \times 10^6\text{ mg P/day} = 3.70\text{ kg P/day}.

  2. Sum both loading pathways: Ltotal=1.30 kg P/day+3.70 kg P/day=5.00 kg P/dayL_{\text{total}} = 1.30\text{ kg P/day} + 3.70\text{ kg P/day} = 5.00\text{ kg P/day}.

  3. Divide by the wetland volume: Accumulation rate=5.00×109 μg/day6.00×108 L≈8.33 μg/(L⋅day)\text{Accumulation rate} = \frac{5.00 \times 10^9\text{ }\mu\text{g/day}}{6.00 \times 10^8\text{ L}} \approx 8.33\text{ }\mu\text{g/(L}\cdot\text{day)}.

Final answer

Total load=5.00 kg P/day; Accumulation rate=8.33 μg/L⋅day\text{Total load} = 5.00\text{ kg P/day};\text{ Accumulation rate} = 8.33\text{ }\mu\text{g/L}\cdot\text{day}

NEXT STEPS
Final Takeaways from Your Teacher
  • Read environmental problem statements carefully for terms like 'benthic flux', 'internal loading', or 'sediment release'.

  • Construct a complete mass-balance equation: Total Inflow = External Inflow + Internal Release - Outflow.

  • Practice multi-step nutrient budget problems that involve converting flux densities (mg/m2\text{mg/m}^2) into total mass rates.

OverviewACEpath Teacher's Diagnosis

02 The student makes a unit conversion error between cubic meters and liters by using 1 m³ = 100 L instead of 1000 L, yielding an accumulation rate that is 10 times too high.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Internal load=18.5 mg/(m2⋅day)×2.00×105 m2=3.70×106 mg/day=3.70 kg P/day\text{Internal load} = 18.5\text{ mg/(m}^2\cdot\text{day)} \times 2.00 \times 10^5\text{ m}^2 = 3.70 \times 10^6\text{ mg/day} = 3.70\text{ kg P/day}

  2. Step 2

    Total daily load=1.30 kg P/day+3.70 kg P/day=5.00 kg P/day\text{Total daily load} = 1.30\text{ kg P/day} + 3.70\text{ kg P/day} = 5.00\text{ kg P/day}

  3. Step 3

    Volume=6.00×105 m3×100 L/m3=6.00×107 L\text{Volume} = 6.00 \times 10^5\text{ m}^3 \times 100\text{ L/m}^3 = 6.00 \times 10^7\text{ L}

    Correct

    Volume=6.00×105 m3×1000 L/m3=6.00×108 L\text{Volume} = 6.00 \times 10^5\text{ m}^3 \times 1000\text{ L/m}^3 = 6.00 \times 10^8\text{ L}

    You used a conversion factor of 100 L/m3100\text{ L/m}^3, but one cubic meter equals 1000 L1000\text{ L} (since 1 m3=(10 dm)3=1000 dm3=1000 L1\text{ m}^3 = (10\text{ dm})^3 = 1000\text{ dm}^3 = 1000\text{ L}).

  4. Step 4

    Accumulation rate=5.00×109 μg P/day6.00×107 L=83.3 μg/(L⋅day)\text{Accumulation rate} = \frac{5.00 \times 10^9\text{ }\mu\text{g P/day}}{6.00 \times 10^7\text{ L}} = 83.3\text{ }\mu\text{g/(L}\cdot\text{day)}

    Correct

    Accumulation rate=5.00×109 μg P/day6.00×108 L≈8.33 μg/(L⋅day)\text{Accumulation rate} = \frac{5.00 \times 10^9\text{ }\mu\text{g P/day}}{6.00 \times 10^8\text{ L}} \approx 8.33\text{ }\mu\text{g/(L}\cdot\text{day)}

    Your division and daily mass conversion to micrograms were carried out accurately, but dividing by the underestimated volume produced a value ten times too large.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly multiplied the benthic flux by the surface area and converted milligrams to kilograms to get the internal phosphorus load.

You correctly combined the internal and external daily phosphorus inputs to determine the total daily phosphorus load.

You correctly converted kilograms of phosphorus to micrograms (1 kg=109 μg1\text{ kg} = 10^9\text{ }\mu\text{g}).

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Metric volume conversion error

You wrote 100 L/m3100\text{ L/m}^3 instead of 1000 L/m31000\text{ L/m}^3, which reduced the wetland volume by a factor of 10.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the linear metric prefix multiplier (100 cm=1 m100\text{ cm} = 1\text{ m}) with three-dimensional volume conversion (1 m3=1000 L1\text{ m}^3 = 1000\text{ L}).

REASONING PATH
Your ACEpath teacher’s suggested approach
Cubic Meters to Liters Conversion
  • 1 m3=1000 L=103 dm3=106 cm31\text{ m}^3 = 1000\text{ L} = 10^3\text{ dm}^3 = 10^6\text{ cm}^3

  • Always convert cubic meters to liters by multiplying by 103 L/m310^3\text{ L/m}^3 because 1 L=1 dm31\text{ L} = 1\text{ dm}^3 and (10 dm)3=1000 dm3(10\text{ dm})^3 = 1000\text{ dm}^3.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Wetland volume in liters=6.00×105 m3×1000 L/m3=6.00×108 L\text{Wetland volume in liters} = 6.00 \times 10^5\text{ m}^3 \times 1000\text{ L/m}^3 = 6.00 \times 10^8\text{ L}

  2. Daily phosphorus mass in micrograms=5.00 kg P/day×109 μg/kg=5.00×109 μg P/day\text{Daily phosphorus mass in micrograms} = 5.00\text{ kg P/day} \times 10^9\text{ }\mu\text{g/kg} = 5.00 \times 10^9\text{ }\mu\text{g P/day}

  3. Accumulation rate=5.00×109 μg P/day6.00×108 L=506 μg/(L⋅day)≈8.33 μg/(L⋅day)\text{Accumulation rate} = \frac{5.00 \times 10^9\text{ }\mu\text{g P/day}}{6.00 \times 10^8\text{ L}} = \frac{50}{6}\text{ }\mu\text{g/(L}\cdot\text{day)} \approx 8.33\text{ }\mu\text{g/(L}\cdot\text{day)}

Final answer

Total load=5.00 kg P/day; Accumulation rate=8.33 μg/L⋅day\text{Total load} = 5.00\text{ kg P/day};\text{ Accumulation rate} = 8.33\text{ }\mu\text{g/L}\cdot\text{day}

NEXT STEPS
Final Takeaways from Your Teacher
  • Double-check derived SI volume units before computing concentrations: remember that 1 m31\text{ m}^3 holds exactly 1000 L1000\text{ L}.

  • Perform a sanity check on unit dimensional cancellation: (kg/day)×(109 μg/kg)/(m3×103 L/m3)=106 μg/(m3⋅day)(\text{kg/day}) \times (10^9\text{ }\mu\text{g/kg}) / (\text{m}^3 \times 10^3\text{ L/m}^3) = 10^6\text{ }\mu\text{g}/(\text{m}^3\cdot\text{day}).

OverviewACEpath Teacher's Diagnosis

03 The student mistakenly applies the 60.0% external load reduction to the already post-mitigation tributary inflow, reducing 1.30 kg P/day to 0.52 kg P/day.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    Internal load=18.5 mg/(m2⋅day)×2.00×105 m2  ⟹  3.70 kg P/day\text{Internal load} = 18.5\text{ mg/(m}^2\cdot\text{day)} \times 2.00 \times 10^5\text{ m}^2 \implies 3.70\text{ kg P/day}

  2. Step 2

    Reduced external load=1.30 kg P/day×(1−0.60)  ⟹  0.52 kg P/day\text{Reduced external load} = 1.30\text{ kg P/day} \times (1 - 0.60) \implies 0.52\text{ kg P/day}

    Correct

    Lext=1.30 kg P/dayL_{\text{ext}} = 1.30\text{ kg P/day}

    You applied a 60.0%60.0\% reduction to the given tributary load, but the problem states that 1.30 kg P/day1.30\text{ kg P/day} is already the post-mitigation tributary inflow.

  3. Step 3

    Total daily load=3.70 kg P/day+0.52 kg P/day  ⟹  4.22 kg P/day\text{Total daily load} = 3.70\text{ kg P/day} + 0.52\text{ kg P/day} \implies 4.22\text{ kg P/day}

    Correct

    Ltotal=3.70 kg P/day+1.30 kg P/day=5.00 kg P/dayL_{\text{total}} = 3.70\text{ kg P/day} + 1.30\text{ kg P/day} = 5.00\text{ kg P/day}

    You summed the internal and external components correctly, but the resulting total is affected by the incorrect external load.

  4. Step 4

    Volume=6.00×108 L  ⟹  Total load=4.22×109 \mug P/day  ⟹  Accumulation rate=4.22×109 \mug P/day6.00×108 L=7.03 \mug/(L⋅day)\text{Volume} = 6.00 \times 10^8\text{ L} \implies \text{Total load} = 4.22 \times 10^9\text{ \mu g P/day} \implies \text{Accumulation rate} = \frac{4.22 \times 10^9\text{ \mu g P/day}}{6.00 \times 10^8\text{ L}} = 7.03\text{ \mu g/(L}\cdot\text{day)}

    Correct

    Accumulation rate=5.00×109 \mug P/day6.00×108 L≈8.33 \mug/(L⋅day)\text{Accumulation rate} = \frac{5.00 \times 10^9\text{ \mu g P/day}}{6.00 \times 10^8\text{ L}} \approx 8.33\text{ \mu g/(L}\cdot\text{day)}

    You applied the proper volume conversion and rate equation, but the final numerical value is lower than expected due to the earlier external load error.

WHAT YOU DID WELL
Compliments from Your Teacher

You accurately calculated the internal phosphorus load from the sediment flux rate and basin area.

You converted units between cubic meters, liters, kilograms, and micrograms without algebraic error.

You used the correct relationship between mass inflow and volumetric accumulation rate.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Double-discounting an already reduced quantity

You reduced the tributary inflow by 60.0%60.0\%, overlooking that the prompt defined the 1.30 kg P/day1.30\text{ kg P/day} figure as post-mitigation.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Misinterpreting the temporal framing of given rates leads to applying hypothetical or policy-target percentage reductions to values that have already been adjusted.

REASONING PATH
Your ACEpath teacher’s suggested approach
Check Baseline vs. Post-Mitigation Framing
  • If a parameter is described with a modifier like 'post-mitigation', 'residual', or 'remaining', it already incorporates the reduction.

  • Scan whether the numeric value describes the pre-treatment baseline or the already mitigated flux before multiplying by (1−r)(1 - r).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the given external post-mitigation tributary inflow directly as Lext=1.30 kg P/dayL_{\text{ext}} = 1.30\text{ kg P/day}.

  2. Add the internal benthic release to the post-mitigation inflow: Ltotal=3.70 kg P/day+1.30 kg P/day=5.00 kg P/dayL_{\text{total}} = 3.70\text{ kg P/day} + 1.30\text{ kg P/day} = 5.00\text{ kg P/day}.

  3. Convert the wetland volume to liters: V=6.00×105 m3×1000 L/m3=6.00×108 LV = 6.00 \times 10^5\text{ m}^3 \times 1000\text{ L/m}^3 = 6.00 \times 10^8\text{ L}.

  4. Convert daily load to micrograms: 5.00 kg P/day×109 \mug/kg=5.00×109 \mug P/day5.00\text{ kg P/day} \times 10^9\text{ \mu g/kg} = 5.00 \times 10^9\text{ \mu g P/day}.

  5. Divide total load by volume: 5.00×109 \mug P/day6.00×108 L≈8.33 \mug/(L⋅day)\frac{5.00 \times 10^9\text{ \mu g P/day}}{6.00 \times 10^8\text{ L}} \approx 8.33\text{ \mu g/(L}\cdot\text{day)}.

Final answer

Total load=5.00 kg P/day; Accumulation rate=8.33 \mug/(L⋅day)\text{Total load} = 5.00\text{ kg P/day};\text{ Accumulation rate} = 8.33\text{ \mu g/(L}\cdot\text{day)}

NEXT STEPS
Final Takeaways from Your Teacher
  • Annotate given values in ecological word problems with explicit state tags such as 'pre-mitigation' or 'post-mitigation'.

  • Verify total nutrient load equations by clearly listing both internal release and external tributary inputs before dividing by total volume.

Lock it in

Similar question

01

A reservoir has an external phosphorus input of 2.5 kg P/day2.5\text{ kg P/day}. The sediment surface area is 1.5×105 m21.5 \times 10^5\text{ m}^2, with an internal release rate of 10.0 mg P/(m2⋅day)10.0\text{ mg P/(m}^2\cdot\text{day)} during summer hypoxia. Calculate the total daily phosphorus load entering the water column in kg P/day\text{kg P/day}.

Answer

4.0 kg P/day4.0\text{ kg P/day}. Key steps: Internal load =10.0 mg/(m2⋅day)×1.5×105 m2=1.5×106 mg/day=1.5 kg/day= 10.0\text{ mg/(m}^2\cdot\text{day)} \times 1.5 \times 10^5\text{ m}^2 = 1.5 \times 10^6\text{ mg/day} = 1.5\text{ kg/day}. Total load =2.5 kg/day+1.5 kg/day=4.0 kg/day= 2.5\text{ kg/day} + 1.5\text{ kg/day} = 4.0\text{ kg/day}.

02

A retention pond of volume 2.0×105 m32.0 \times 10^5\text{ m}^3 has zero outflow during dry summer months. It receives 0.80 kg P/day0.80\text{ kg P/day} from stormwater runoff and generates 1.20 kg P/day1.20\text{ kg P/day} via anoxic benthic release. Calculate the daily phosphorus concentration increase in μg/(L⋅day)\mu\text{g/(L}\cdot\text{day)}.

Answer

10.0 μg/(L⋅day)10.0\text{ }\mu\text{g/(L}\cdot\text{day)}. Key steps: Total load =0.80+1.20=2.00 kg/day=2.00×109 μg/day= 0.80 + 1.20 = 2.00\text{ kg/day} = 2.00 \times 10^9\text{ }\mu\text{g/day}. Volume =2.0×105 m3×1000 L/m3=2.0×108 L= 2.0 \times 10^5\text{ m}^3 \times 1000\text{ L/m}^3 = 2.0 \times 10^8\text{ L}. Concentration increase =2.00×109 μg/day2.0×108 L=10.0 μg/(L⋅day)= \frac{2.00 \times 10^9\text{ }\mu\text{g/day}}{2.0 \times 10^8\text{ L}} = 10.0\text{ }\mu\text{g/(L}\cdot\text{day)}.

03

An urban shallow lake (A=4.0×105 m2A = 4.0 \times 10^5\text{ m}^2, V=1.2×106 m3V = 1.2 \times 10^6\text{ m}^3) has an internal anoxic flux of 15.0 mg P/(m2⋅day)15.0\text{ mg P/(m}^2\cdot\text{day)}. Environmental managers want the total phosphorus accumulation rate not to exceed 7.0 μg/(L⋅day)7.0\text{ }\mu\text{g/(L}\cdot\text{day)} during stagnant summer periods. What is the maximum allowable external tributary load in kg P/day\text{kg P/day}?

Answer

2.4 kg P/day2.4\text{ kg P/day}. Key steps: Internal load =15.0 mg/(m2⋅day)×4.0×105 m2=6.0 kg/day= 15.0\text{ mg/(m}^2\cdot\text{day)} \times 4.0 \times 10^5\text{ m}^2 = 6.0\text{ kg/day}. Maximum total daily load =(7.0 μg/(L⋅day))×(1.2×109 L)=8.4×109 μg/day=8.4 kg/day= (7.0\text{ }\mu\text{g/(L}\cdot\text{day)}) \times (1.2 \times 10^9\text{ L}) = 8.4 \times 10^9\text{ }\mu\text{g/day} = 8.4\text{ kg/day}. Allowable external load =8.4−6.0=2.4 kg P/day= 8.4 - 6.0 = 2.4\text{ kg P/day}.