Resources

In a recombinant cloning experiment using high-copy pUC-derived plasmids in E. coliE.\ coli, a student hypothesizes that competent bacterial cells will yield a higher absolute number of transformed colonies if transformed with 50.0 ng50.0\text{ ng} of intact circular plasmid DNA compared to 1.00 ng1.00\text{ ng} of the identical plasmid. The student transforms equal volumes (100 μL100\ \mu\text{L}) of competent cells with either 1.00 ng1.00\text{ ng} or 50.0 ng50.0\text{ ng} of plasmid DNA, recovers each in 1.00 mL1.00\text{ mL} SOC medium, and plates 100 μL100\ \mu\text{L} of each dilution. The 1.00 ng1.00\text{ ng} transformation yields 120 CFU120\text{ CFU} on the plate, while the 50.0 ng50.0\text{ ng} transformation yields 1800 CFU1800\text{ CFU}. Calculate: (a) the transformation efficiency in CFU/μg\text{CFU}/\mu\text{g} for both the 1.00 ng1.00\text{ ng} and 50.0 ng50.0\text{ ng} reactions, and (b) explain the quantitative discrepancy demonstrating why transformation efficiency decreases at elevated DNA concentrations.

Answer and steps

Final answer

(a) 1.00 ng1.00\text{ ng} reaction: 1.20×106 CFU/μg1.20 \times 10^6\text{ CFU}/\mu\text{g}; 50.0 ng50.0\text{ ng} reaction: 3.60×105 CFU/μg3.60 \times 10^5\text{ CFU}/\mu\text{g}; (b) The transformation efficiency decreases by a factor of 3.333.33 at 50.0 ng50.0\text{ ng} because competent cell uptake channels become saturated at high DNA concentrations, leading to a plateau in colony yield.

Steps

01

Transformation with 1.00 ng1.00\text{ ng} of DNA

Part (a): Calculating Transformation Efficiency

Transformation efficiency (TE\text{TE}) measures the number of colony-forming units (CFU\text{CFU}) produced per microgram of plasmid DNA. The standard formula is: Transformation Efficiency=Total CFUMass of DNA transformed (μg)\text{Transformation Efficiency} = \frac{\text{Total CFU}}{\text{Mass of DNA transformed}\ (\mu\text{g})} where the total number of colonies generated in the entire transformation suspension is determined by: Total CFU=Colonies counted on plate×Total suspension volumeVolume plated\text{Total CFU} = \text{Colonies counted on plate} \times \frac{\text{Total suspension volume}}{\text{Volume plated}}

  • Step 1: Convert DNA mass to micrograms (μg\mu\text{g}): 1.00 ng=1.00×10−3 μg1.00\text{ ng} = 1.00 \times 10^{-3}\ \mu\text{g}
  • Step 2: Determine total CFU in the recovery mixture: The cells were recovered in a total volume of 1.00 mL=1000 μL1.00\text{ mL} = 1000\ \mu\text{L}, and 100 μL100\ \mu\text{L} was plated (a dilution factor of 1000 μL100 μL=10\frac{1000\ \mu\text{L}}{100\ \mu\text{L}} = 10): Total CFU=120 CFU×1000 μL100 μL=1200 CFU\text{Total CFU} = 120\text{ CFU} \times \frac{1000\ \mu\text{L}}{100\ \mu\text{L}} = 1200\text{ CFU}
  • Step 3: Calculate efficiency: TE1.00 ng=1200 CFU1.00×10−3 μg=1.20×106 CFU/μg\text{TE}_{1.00\text{ ng}} = \frac{1200\text{ CFU}}{1.00 \times 10^{-3}\ \mu\text{g}} = 1.20 \times 10^6\text{ CFU}/\mu\text{g}

02

Transformation with 50.0 ng50.0\text{ ng} of DNA

  • Step 1: Convert DNA mass to micrograms (μg\mu\text{g}): 50.0 ng=5.00×10−2 μg50.0\text{ ng} = 5.00 \times 10^{-2}\ \mu\text{g}
  • Step 2: Determine total CFU in the recovery mixture: Total CFU=1800 CFU×1000 μL100 μL=18000 CFU\text{Total CFU} = 1800\text{ CFU} \times \frac{1000\ \mu\text{L}}{100\ \mu\text{L}} = 18000\text{ CFU}
  • Step 3: Calculate efficiency: TE50.0 ng=18000 CFU5.00×10−2 μg=3.60×105 CFU/μg\text{TE}_{50.0\text{ ng}} = \frac{18000\text{ CFU}}{5.00 \times 10^{-2}\ \mu\text{g}} = 3.60 \times 10^5\text{ CFU}/\mu\text{g}

Part (b): Explaining the Quantitative Discrepancy

Comparing the two efficiencies:

TE1.00 ngTE50.0 ng=1.20×106 CFU/μg3.60×105 CFU/μg≈3.33\frac{\text{TE}_{1.00\text{ ng}}}{\text{TE}_{50.0\text{ ng}}} = \frac{1.20 \times 10^6\text{ CFU}/\mu\text{g}}{3.60 \times 10^5\text{ CFU}/\mu\text{g}} \approx 3.33

The transformation efficiency decreases by a factor of 3.333.33 when the DNA amount is increased to 50.0 ng50.0\text{ ng}.

  • Biological mechanism: Although the absolute number of colonies increases (from 120120 to 1800 CFU1800\text{ CFU} on the plate), the increase is non-linear. The entry sites and channels on the surface of competent E. coli cells become saturated at high plasmid concentrations.
  • Once the uptake capacity of the competent population is saturated, excess plasmid molecules cannot enter the cells and remain unutilized, resulting in a lower ratio of successful transformation events per microgram of input DNA.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to account for the plating fraction and calculates efficiency using the total mass of DNA added to the transformation rather than the fraction plated.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    1.00 ng=0.001 μg  ⟹  Efficiency (1.00 ng)=120 CFU/0.001 μg=1.20×105 CFU/μg1.00\text{ ng} = 0.001\ \mu\text{g} \implies \text{Efficiency } (1.00\text{ ng}) = 120\text{ CFU} / 0.001\ \mu\text{g} = 1.20 \times 10^5\text{ CFU}/\mu\text{g}

    Correct

    TE1.00 ng=120 CFU×1000 μL100 μL1.00×10−3 μg=1.20×106 CFU/μg\text{TE}_{1.00\text{ ng}} = \frac{120\text{ CFU} \times \frac{1000\ \mu\text{L}}{100\ \mu\text{L}}}{1.00 \times 10^{-3}\ \mu\text{g}} = 1.20 \times 10^6\text{ CFU}/\mu\text{g}

    You calculated efficiency using the colonies counted on the plate directly against the total mass of transformed DNA, forgetting that only 100 μL100\ \mu\text{L} out of the total 1.00 mL1.00\text{ mL} (1000 μL1000\ \mu\text{L}) recovery volume was plated.

  2. Step 2

    50.0 ng=0.050 μg  ⟹  Efficiency (50.0 ng)=1800 CFU/0.050 μg=3.60×104 CFU/μg50.0\text{ ng} = 0.050\ \mu\text{g} \implies \text{Efficiency } (50.0\text{ ng}) = 1800\text{ CFU} / 0.050\ \mu\text{g} = 3.60 \times 10^4\text{ CFU}/\mu\text{g}

    Correct

    TE50.0 ng=1800 CFU×1000 μL100 μL5.00×10−2 μg=3.60×105 CFU/μg\text{TE}_{50.0\text{ ng}} = \frac{1800\text{ CFU} \times \frac{1000\ \mu\text{L}}{100\ \mu\text{L}}}{5.00 \times 10^{-2}\ \mu\text{g}} = 3.60 \times 10^5\text{ CFU}/\mu\text{g}

    You repeated the omission of the plating fraction (100 μL1000 μL=0.1\frac{100\ \mu\text{L}}{1000\ \mu\text{L}} = 0.1), underestimating the efficiency by a factor of 1010.

  3. Step 3

    Transformation efficiency drops because competent cell uptake machinery becomes saturated at high DNA concentrations, so additional DNA does not increase colony formation proportionately.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly converted input DNA mass from nanograms to micrograms.

You correctly identified competent cell uptake saturation as the biological reason for reduced transformation efficiency.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of Plating Fraction in Transformation Efficiency

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the colony count from a subsample aliquot as representing the entire transformation recovery volume, rather than multiplying by the dilution/plating factor (or dividing by the mass of DNA actually spread on the plate).

REASONING PATH
Your ACEpath teacher’s suggested approach
Account for the Plating Fraction
  • TE=Colonies on plateDNA mass plated (μg)=Colonies on plate×(VtotalVplated)Total DNA mass (μg)\text{TE} = \frac{\text{Colonies on plate}}{\text{DNA mass plated (}\mu\text{g)}} = \frac{\text{Colonies on plate} \times \left(\frac{V_{\text{total}}}{V_{\text{plated}}}\right)}{\text{Total DNA mass (}\mu\text{g)}}

  • Always determine the fraction of the recovery suspension that was actually plated (VplatedVtotal\frac{V_{\text{plated}}}{V_{\text{total}}}) before dividing colony counts by input DNA mass.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Scale up plate counts to total recovery volume: Total CFU=Colonies×1000 μL100 μL=10×Colonies\text{Total CFU} = \text{Colonies} \times \frac{1000\ \mu\text{L}}{100\ \mu\text{L}} = 10 \times \text{Colonies}.

  2. Calculate 1.00 ng1.00\text{ ng} efficiency: TE=120×101.00×10−3 μg=1.20×106 CFU/μg\text{TE} = \frac{120 \times 10}{1.00 \times 10^{-3}\ \mu\text{g}} = 1.20 \times 10^6\text{ CFU}/\mu\text{g}.

  3. Calculate 50.0 ng50.0\text{ ng} efficiency: TE=1800×105.00×10−2 μg=3.60×105 CFU/μg\text{TE} = \frac{1800 \times 10}{5.00 \times 10^{-2}\ \mu\text{g}} = 3.60 \times 10^5\text{ CFU}/\mu\text{g}.

Final answer

(a) 1.00 ng1.00\text{ ng} reaction: 1.20×106 CFU/μg1.20 \times 10^6\text{ CFU}/\mu\text{g}; 50.0 ng50.0\text{ ng} reaction: 3.60×105 CFU/μg3.60 \times 10^5\text{ CFU}/\mu\text{g}; (b) The efficiency drops by a factor of 3.333.33 due to saturation of competent cell uptake channels.

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out the full transformation efficiency formula including the volume fraction factor before substituting values.

  • Verify whether the mass in the denominator represents total transformed DNA or only the mass present in the plated aliquot.

OverviewACEpath Teacher's Diagnosis

02 The student inverts or misapplies the nanogram to microgram unit conversion by multiplying by 1000 instead of dividing.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Fraction plated=100 μL1000 μL=0.1\text{Fraction plated} = \frac{100\ \mu\text{L}}{1000\ \mu\text{L}} = 0.1

  2. Step 2

    DNA plated (1.00 ng)=0.1 ng=100 μg  ⟹  Efficiency (1.00 ng)=120 CFU100 μg=1.20 CFU/μg\text{DNA plated } (1.00\text{ ng}) = 0.1\text{ ng} = 100\ \mu\text{g} \implies \text{Efficiency } (1.00\text{ ng}) = \frac{120\text{ CFU}}{100\ \mu\text{g}} = 1.20\text{ CFU}/\mu\text{g}

    Correct

    DNA plated (1.00 ng)=0.100 ng=1.00×10−4 μg  ⟹  Efficiency=120 CFU1.00×10−4 μg=1.20×106 CFU/μg\text{DNA plated } (1.00\text{ ng}) = 0.100\text{ ng} = 1.00 \times 10^{-4}\ \mu\text{g} \implies \text{Efficiency} = \frac{120\text{ CFU}}{1.00 \times 10^{-4}\ \mu\text{g}} = 1.20 \times 10^6\text{ CFU}/\mu\text{g}

    You multiplied by 10001000 instead of dividing by 10001000 when converting nanograms to micrograms (1 μg=1000 ng1\ \mu\text{g} = 1000\text{ ng}, so 0.1 ng=1.00×10−4 μg0.1\text{ ng} = 1.00 \times 10^{-4}\ \mu\text{g}).

  3. Step 3

    DNA plated (50.0 ng)=5.0 ng=5000 μg  ⟹  Efficiency (50.0 ng)=1800 CFU5000 μg=0.36 CFU/μg\text{DNA plated } (50.0\text{ ng}) = 5.0\text{ ng} = 5000\ \mu\text{g} \implies \text{Efficiency } (50.0\text{ ng}) = \frac{1800\text{ CFU}}{5000\ \mu\text{g}} = 0.36\text{ CFU}/\mu\text{g}

    Correct

    DNA plated (50.0 ng)=5.00 ng=5.00×10−3 μg  ⟹  Efficiency=1800 CFU5.00×10−3 μg=3.60×105 CFU/μg\text{DNA plated } (50.0\text{ ng}) = 5.00\text{ ng} = 5.00 \times 10^{-3}\ \mu\text{g} \implies \text{Efficiency} = \frac{1800\text{ CFU}}{5.00 \times 10^{-3}\ \mu\text{g}} = 3.60 \times 10^5\text{ CFU}/\mu\text{g}

    You repeated the same conversion error here, multiplying 5.0 ng5.0\text{ ng} by 10001000 to get 5000 μg5000\ \mu\text{g} instead of dividing to get 0.005 μg0.005\ \mu\text{g}.

  4. Step 4

    Efficiency decreases at higher DNA concentrations because the cell surface receptors and membrane pores responsible for DNA uptake become saturated.\text{Efficiency decreases at higher DNA concentrations because the cell surface receptors and membrane pores responsible for DNA uptake become saturated.}

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the dilution fraction from the plated and total recovery volumes.

You used the correct conceptual formula for transformation efficiency: colonies divided by the mass of DNA plated.

You correctly explained the biological mechanism of uptake channel saturation at elevated plasmid concentrations.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Metric Unit Inversion Error

You treated nanograms as larger than micrograms, writing 0.1 ng=100 μg0.1\text{ ng} = 100\ \mu\text{g} rather than 0.1 ng=1.00×10−4 μg0.1\text{ ng} = 1.00 \times 10^{-4}\ \mu\text{g}.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Inverting the conversion factor between metric prefix tiers (nano to micro) caused the mass in the denominator to be overstated by a factor of 10610^6, shrinking the final efficiency values by six orders of magnitude.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Magnitude Sanity Check
  • 1 μg=10−6 g1\ \mu\text{g} = 10^{-6}\text{ g} and 1 ng=10−9 g1\text{ ng} = 10^{-9}\text{ g}, so 1 μg=1000 ng1\ \mu\text{g} = 1000\text{ ng}.

  • When converting from a smaller prefix (nano) to a larger prefix (micro), divide by 10001000 (mμg=mng1000m_{\mu\text{g}} = \frac{m_{\text{ng}}}{1000}).

Standard Efficiency Ranges
  • Commercial chemically competent cells typically yield 10610^6 to 109 CFU/μg10^9\text{ CFU}/\mu\text{g}.

  • If your calculated efficiency is near 1 CFU/μg1\text{ CFU}/\mu\text{g}, check whether your DNA mass was mistakenly converted to a number of micrograms greater than the nanogram value.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Convert the plated DNA mass correctly: m=0.100 ng×1 μg1000 ng=1.00×10−4 μgm = 0.100\text{ ng} \times \frac{1\ \mu\text{g}}{1000\text{ ng}} = 1.00 \times 10^{-4}\ \mu\text{g}.

  2. Calculate efficiency for 1.00 ng1.00\text{ ng}: TE=120 CFU1.00×10−4 μg=1.20×106 CFU/μg\text{TE} = \frac{120\text{ CFU}}{1.00 \times 10^{-4}\ \mu\text{g}} = 1.20 \times 10^6\text{ CFU}/\mu\text{g}.

  3. Convert the plated DNA mass for 50.0 ng50.0\text{ ng}: m=5.00 ng×1 μg1000 ng=5.00×10−3 μgm = 5.00\text{ ng} \times \frac{1\ \mu\text{g}}{1000\text{ ng}} = 5.00 \times 10^{-3}\ \mu\text{g}.

  4. Calculate efficiency for 50.0 ng50.0\text{ ng}: TE=1800 CFU5.00×10−3 μg=3.60×105 CFU/μg\text{TE} = \frac{1800\text{ CFU}}{5.00 \times 10^{-3}\ \mu\text{g}} = 3.60 \times 10^5\text{ CFU}/\mu\text{g}.

Final answer

(a) 1.00 ng1.00\text{ ng} reaction: 1.20×106 CFU/μg1.20 \times 10^6\text{ CFU}/\mu\text{g}; 50.0 ng50.0\text{ ng} reaction: 3.60×105 CFU/μg3.60 \times 10^5\text{ CFU}/\mu\text{g}; (b) The transformation efficiency decreases at higher DNA concentrations because competent cell uptake channels become saturated.

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out dimensional analysis brackets explicitly (0.1 ng×1 μg103 ng0.1\text{ ng} \times \frac{1\ \mu\text{g}}{10^3\text{ ng}}) to prevent unit inversions.

  • Check whether your computed efficiency falls within the typical benchmark range of 10610^6 to 109 CFU/μg10^9\text{ CFU}/\mu\text{g} for competent E. coli.

  • Practice converting values between picograms, nanograms, and micrograms using scientific notation.

OverviewACEpath Teacher's Diagnosis

03 The student attributes the decrease in efficiency to plasmid toxicity or antibiotic dilution rather than saturation of competent cell uptake capacity.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    Fraction plated=100 μL1000 μL=0.1  ⟹  DNA plated (1.00 ng)=0.100 ng=1.00×10−4 μg  ⟹  Efficiency (1.00 ng)=120 CFU1.00×10−4 μg=1.20×106 CFU/μg\text{Fraction plated} = \frac{100\ \mu\text{L}}{1000\ \mu\text{L}} = 0.1 \implies \text{DNA plated } (1.00\text{ ng}) = 0.100\text{ ng} = 1.00 \times 10^{-4}\ \mu\text{g} \implies \text{Efficiency } (1.00\text{ ng}) = \frac{120\text{ CFU}}{1.00 \times 10^{-4}\ \mu\text{g}} = 1.20 \times 10^6\text{ CFU}/\mu\text{g}

  2. Step 2

    DNA plated (50.0 ng)=5.00 ng=5.00×10−3 μg  ⟹  Efficiency (50.0 ng)=1800 CFU5.00×10−3 μg=3.60×105 CFU/μg\text{DNA plated } (50.0\text{ ng}) = 5.00\text{ ng} = 5.00 \times 10^{-3}\ \mu\text{g} \implies \text{Efficiency } (50.0\text{ ng}) = \frac{1800\text{ CFU}}{5.00 \times 10^{-3}\ \mu\text{g}} = 3.60 \times 10^5\text{ CFU}/\mu\text{g}

  3. Step 3

    The efficiency decreases because having too much plasmid DNA is toxic to the bacteria and kills the cells before they can divide.

    Correct

    Efficiency decreases because the competent cell membrane uptake sites become saturated at elevated DNA concentrations, meaning excess plasmid molecules cannot be taken up even though absolute colony yield still rises.

    Plasmid DNA is not cytotoxic at standard transformation concentrations, and the absolute colony count actually increased from 120120 to 1800 CFU1800\text{ CFU}. The drop in efficiency is due to saturation of the competent cells' DNA uptake channels.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the fraction of recovery culture plated.

You determined the accurate transformation efficiency for both the 1.00 ng1.00\text{ ng} and 50.0 ng50.0\text{ ng} reactions using appropriate units.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
saturation vs cytotoxicity misconception

You attributed the decrease in transformation efficiency to plasmid DNA cytotoxicity killing the cells.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused transport saturation kinetics with cell death, overlooking that the absolute colony count still increased 15-fold (120120 to 1800 CFU1800\text{ CFU}), which proves cells were successfully surviving and dividing.

REASONING PATH
Your ACEpath teacher’s suggested approach
Absolute Yield vs. Efficiency
  • Transformation efficiency is colonies per microgram of input DNA, while yield is the raw colony count.

  • Check whether raw colony count increases; if it increases, cells are not being killed by toxicity.

Uptake Site Saturation
  • Competent bacterial cells possess a finite number of transient channels or entry complexes capable of taking up DNA during heat shock or electroporation.

  • Attribute diminishing returns in efficiency at high DNA amounts to saturation of uptake capacity, not DNA toxicity.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Notice that raw colony count increased from 120 CFU120\text{ CFU} to 1800 CFU1800\text{ CFU}, demonstrating that high plasmid DNA did not kill the bacterial cells.

  2. Recognize that each competent cell has a finite capacity and number of transient entry pores for DNA uptake during transformation.

  3. At 50.0 ng50.0\text{ ng}, the concentration of plasmid molecules exceeds this uptake capacity, so additional plasmid DNA remains outside without producing additional transformants.

Final answer

(a) 1.00 ng1.00\text{ ng} reaction: 1.20×106 CFU/μg1.20 \times 10^6\text{ CFU}/\mu\text{g}; 50.0 ng50.0\text{ ng} reaction: 3.60×105 CFU/μg3.60 \times 10^5\text{ CFU}/\mu\text{g}; (b) The efficiency decreases because the finite DNA uptake channels of competent cells become saturated at high plasmid concentrations, leading to plateauing yields per unit mass of DNA rather than cell death.

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the kinetic curve of transformation efficiency versus plasmid DNA concentration to see where saturation begins.

  • Practice distinguishing between biological toxicity (which reduces total colony counts) and transport saturation (which increases total counts but reduces efficiency).

Lock it in

Similar question

01

A student transforms 10.0 ng10.0\text{ ng} of pUC19 plasmid into competent E. coli. The cells are recovered in 900 μL900\ \mu\text{L} of SOC medium (total volume 1000 μL1000\ \mu\text{L} including cell suspension). A 50 μL50\ \mu\text{L} aliquot is spread onto an ampicillin agar plate, yielding 150 CFU150\text{ CFU}. Calculate the transformation efficiency in CFU/μg\text{CFU}/\mu\text{g}.

Answer

3.00×105 CFU/μg3.00 \times 10^5\text{ CFU}/\mu\text{g}. The plating fraction is 50 μL1000 μL=120\frac{50\ \mu\text{L}}{1000\ \mu\text{L}} = \frac{1}{20}. Total colonies = 150×20=3000 CFU150 \times 20 = 3000\text{ CFU}. Total DNA mass = 10.0 ng=0.010 μg10.0\text{ ng} = 0.010\ \mu\text{g}. Thus, TE=3000 CFU0.010 μg=3.00×105 CFU/μg\text{TE} = \frac{3000\text{ CFU}}{0.010\ \mu\text{g}} = 3.00 \times 10^5\text{ CFU}/\mu\text{g}.

02

In a molecular cloning assay, 2.00 μL2.00\ \mu\text{L} of plasmid at a concentration of 25.0 pg/μL25.0\text{ pg}/\mu\text{L} is added to 50 μL50\ \mu\text{L} of competent cells. Following heat shock, 450 μL450\ \mu\text{L} of SOC medium is added (total volume 500 μL500\ \mu\text{L}). If 100 μL100\ \mu\text{L} is plated and produces 240 CFU240\text{ CFU}, calculate the transformation efficiency in CFU/μg\text{CFU}/\mu\text{g}.

Answer

2.40×107 CFU/μg2.40 \times 10^7\text{ CFU}/\mu\text{g}. Total DNA = 2.00 μL×25.0 pg/μL=50.0 pg=5.00×10−5 μg2.00\ \mu\text{L} \times 25.0\text{ pg}/\mu\text{L} = 50.0\text{ pg} = 5.00 \times 10^{-5}\ \mu\text{g}. Plating factor = 500 μL100 μL=5\frac{500\ \mu\text{L}}{100\ \mu\text{L}} = 5. Total colonies = 240×5=1200 CFU240 \times 5 = 1200\text{ CFU}. TE=1200 CFU5.00×10−5 μg=2.40×107 CFU/μg\text{TE} = \frac{1200\text{ CFU}}{5.00 \times 10^{-5}\ \mu\text{g}} = 2.40 \times 10^7\text{ CFU}/\mu\text{g}.

03

A lab technician needs at least 500 CFU500\text{ CFU} on a single selective plate to pick enough recombinant colonies. The batch of competent cells has an established transformation efficiency of 2.5×106 CFU/μg2.5 \times 10^6\text{ CFU}/\mu\text{g}. If the recovery volume is 1.00 mL1.00\text{ mL} and only 100 μL100\ \mu\text{L} can be spread per plate without flooding, what is the minimum mass of plasmid DNA (in ng) that must be added to the transformation reaction?

Answer

2.0 ng2.0\text{ ng}. Since 100 μL100\ \mu\text{L} out of 1000 μL1000\ \mu\text{L} is plated (fraction 0.10.1), 500 CFU500\text{ CFU} on the plate corresponds to 5000 CFU5000\text{ CFU} total. Using Total DNA=Total CFUTE=5000 CFU2.5×106 CFU/μg=2.0×10−3 μg=2.0 ng\text{Total DNA} = \frac{\text{Total CFU}}{\text{TE}} = \frac{5000\text{ CFU}}{2.5 \times 10^6\text{ CFU}/\mu\text{g}} = 2.0 \times 10^{-3}\ \mu\text{g} = 2.0\text{ ng}.

Loading workspace…