Resources
In a quantitative study of human thermal homeostasis, the overall negative feedback loop gain is modeled by the ratio of corrective physiological response to open-loop perturbation: . A subject at a baseline core temperature set point of enters a cold chamber, which produces an uncompensated passive open-loop drop of . The autonomic negative feedback system responds via shivering thermogenesis and peripheral vasoconstriction, resulting in an observed steady-state regulated core temperature of . Calculate the dimensionless loop gain of this thermoregulatory system.
Answer and steps
Final answer
(dimensionless, or an open-loop feedback gain of magnitude )
Steps
Determine the Error Signal ()
In homeostatic negative feedback, the error signal is the difference between the actual regulated steady-state value and the set point:
Substitute the given values:
Determine the Corrective Physiological Response ()
The net change in core temperature () is the algebraic sum of the passive perturbation caused by the environment and the active physiological compensation (such as shivering and vasoconstriction):
Substitute and :
The physiological mechanisms actively raise the temperature by relative to the uncompensated state.
Calculate the Negative Feedback Loop Gain ()
Using the defined model for open-loop feedback gain:
Substitute the calculated values:
Verification via Closed-Loop Control Formula
In a standard linear negative feedback system, the regulated closed-loop error is attenuated by a factor of :
Key Pitfall: Ensure correct tracking of negative signs. Because negative feedback acts in the opposite direction of the displacement, the physiological response () opposes the error (), yielding a positive, dimensionless gain .
Typical errors
01 The student misidentifies the passive perturbation itself as the corrective response instead of calculating the net physiological offset, resulting in a loop gain of -6.0.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You treated the uncompensated environmental drop () as the physiological response. The physiological response is the active offset produced by shivering and vasoconstriction that counters this drop: .
- Step 3Correct
Your gain calculation correctly applied your values into the formula, but it inherited the incorrect value for from the previous step.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the steady-state error signal .
You correctly recalled the negative feedback loop gain formula .
You carried out the arithmetic operations and sign tracking accurately according to your written values.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou substituted the external perturbation in place of the active physiological response .
WHY IT HAPPENED
ACEpath Teacher's DiagnosisIn biological homeostatic loops, the observed net deviation represents the sum of the external disturbance () and the corrective homeostatic response (). Confusing the disturbance with the response misses the subtractive nature of negative feedback compensation.
REASONING PATH
Your ACEpath teacher’s suggested approach- Distinguish Disturbance vs. Response
Net Change = Disturbance + Corrective Response: .
Rearrange to solve for the active response: before calculating loop gain.
- Sign Check for Negative Feedback Gain
Negative feedback opposes perturbation, so the corrective response must have the opposite sign of the error signal, giving a positive loop gain .
If your calculated loop gain turns out negative, check whether you assigned the correct opposing sign to the active physiological correction.
CORRECTED PATH
ACEpath Teacher's DemonstrationFind the active physiological correction: .
Substitute and into the gain formula: .
02 The student forgets the negative sign in the negative feedback loop gain formula, calculating G = -5.0 instead of +5.0.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2
- Step 3Correct
You omitted the negative sign in the formula . Because negative feedback opposes the perturbation, the loop gain is defined as a positive quantity.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly identified and computed the steady-state error signal .
You correctly isolated and calculated the compensatory response from the net temperature change.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou left out the leading negative sign in the negative feedback gain formula when substituting your values.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisOverlooking the definition of negative feedback loop gain, where the explicit negative sign ensures that an opposing corrective response yields a positive dimensionless gain .
REASONING PATH
Your ACEpath teacher’s suggested approach- Feedback Gain Sign Convention
In homeostatic control systems, open-loop gain is defined as , ensuring for stable negative feedback.
Always verify that your calculated loop gain is positive for an intact negative feedback loop.
CORRECTED PATH
ACEpath Teacher's DemonstrationApply the negative feedback gain formula: .
Substitute and : .
03 The student computes the response as the difference between the passive perturbation and the steady-state drop rather than the baseline, inverting the numerator to -2.00°C and obtaining G = -5.0.
Sample Student Work
Reviewed by ACEpath TeacherStep-by-Step Review
Walk Through It with Your Teacher- Step 1
- Step 2Correct
You subtracted the final error from the passive perturbation rather than subtracting the perturbation from the observed net change. Since the net change is , the physiological warming response must be positive () to counteract the environmental cooling.
- Step 3Correct
You substituted your negative response value correctly into the given formula, but the sign error from Step 2 carried over to produce a negative gain instead of the expected positive dimensionless gain.
WHAT YOU DID WELL
Compliments from Your TeacherYou correctly calculated the error signal as the deviation from the set point.
You used the correct mathematical relationship for the negative feedback gain formula.
THE ERROR
Where Your ACEpath Teacher Spotted the MistakeYou set up instead of , flipping the physical direction of the warming response.
WHY IT HAPPENED
ACEpath Teacher's DiagnosisConfusing the algebraic components of the net perturbation equation . Because shivering and vasoconstriction act against cooling, the active response must oppose the disturbance with a positive temperature contribution.
REASONING PATH
Your ACEpath teacher’s suggested approach- Biological Directionality Check
In negative feedback, the effector response must actively counteract the disturbance.
Always verify that your computed has the opposite sign of the environmental challenge (e.g., cold exposure requires a positive ).
- Loop Gain Sign Convention
A stable negative feedback control system exhibits a positive open-loop gain when defined with a leading negative sign: .
Check that the final gain is a positive dimensionless value.
CORRECTED PATH
ACEpath Teacher's DemonstrationRe-evaluate the net temperature balance: .
Solve for the response: .
Substitute into the gain formula: .
Lock it in
In a negative feedback homeostatic system, how is the active physiological response related to the passive disturbance and the net error ?
. The net observed change is the sum of the passive perturbation and the active physiological correction.
Similar question
A subject's baseline mean arterial blood pressure set point is . An infusion of a vasodilator would passively drop pressure by in the absence of feedback. Due to baroreceptor reflex activation, the regulated steady-state blood pressure drops to . Calculate the dimensionless open-loop gain of the baroreflex.
Answer
. The active baroreceptor response is . Thus, .
In a glucose regulation study, an intravenous glucose infusion exerts an uncompensated passive perturbation of . Pancreatic insulin release compensates with a negative feedback loop gain of . What is the resulting steady-state error relative to the fasting set point?
Answer
In a linear negative feedback loop, .
During strenuous exercise in hot weather, metabolic heat generation causes an uncompensated thermal perturbation of . The thermoregulatory loop operates with a feedback gain of . If the baseline set point is , determine: (a) the active cooling response , and (b) the final regulated core temperature .
Answer
(a) The regulated error is . The active response is (or via : ). (b) The steady-state temperature is .