Resources

In a study of synthetic liposome membrane permeability at 25 ∘C25\,^{\circ}\text{C}, the flux JJ of a neutral polar organic solute across a membrane of surface area A=4.0×10−4 cm2A = 4.0 \times 10^{-4}\text{ cm}^2 is measured. The concentration difference between the inside and outside compartments is maintained at ΔC=15 mmol/L=15×10−6 mol/cm3\Delta C = 15\text{ mmol/L} = 15 \times 10^{-6}\text{ mol/cm}^3. The observed initial rate of solute mass transfer across the membrane is dndt=1.8×10−11 mol/s\frac{dn}{dt} = 1.8 \times 10^{-11}\text{ mol/s}. Using Fick's first law of diffusion in the form J=1Adndt=PΔCJ = \frac{1}{A}\frac{dn}{dt} = P \Delta C, calculate the permeability coefficient (PP) of this solute in units of cm/s\text{cm/s}.

Answer and steps

Final answer

P=3.0×10−3 cm/sP = 3.0 \times 10^{-3}\text{ cm/s}

Steps

01

Identify and Verify the Units of the Given Values

Method: Applying Fick's First Law Across a Membrane

Fick's first law of diffusion across a membrane relates the rate of solute transport, the membrane area, and the concentration gradient across the membrane: J=1Adndt=PΔCJ = \frac{1}{A}\frac{dn}{dt} = P \Delta C where:

  • JJ is the solute flux in mol/(cm2⋅s)\text{mol}/(\text{cm}^2\cdot\text{s}),
  • dndt\frac{dn}{dt} is the rate of solute transfer in mol/s\text{mol/s},
  • AA is the membrane surface area in cm2\text{cm}^2,
  • PP is the permeability coefficient in cm/s\text{cm/s},
  • ΔC\Delta C is the concentration difference across the membrane in mol/cm3\text{mol/cm}^3.

All quantities must be expressed in compatible units (mol\text{mol}, cm\text{cm}, and s\text{s}):

  • Surface area: A=4.0×10−4 cm2A = 4.0 \times 10^{-4}\text{ cm}^2
  • Transfer rate: dndt=1.8×10−11 mol/s\frac{dn}{dt} = 1.8 \times 10^{-11}\text{ mol/s}
  • Concentration difference: ΔC=15×10−6 mol/cm3\Delta C = 15 \times 10^{-6}\text{ mol/cm}^3

02

Calculate the Solute Flux (JJ)

The solute flux JJ represents the amount of solute crossing per unit area per unit time:

J=1Adndt=1.8×10−11 mol/s4.0×10−4 cm2=4.5×10−8 mol/(cm2⋅s)J = \frac{1}{A}\frac{dn}{dt} = \frac{1.8 \times 10^{-11}\text{ mol/s}}{4.0 \times 10^{-4}\text{ cm}^2} = 4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})


03

Solve for the Permeability Coefficient (PP)

Rearrange the equation J=PΔCJ = P \Delta C to solve for PP:

P=JΔCP = \frac{J}{\Delta C}

Substitute the values:

P=4.5×10−8 mol/(cm2⋅s)15×10−6 mol/cm3=4.5×10−81.5×10−5 cm/s=3.0×10−3 cm/sP = \frac{4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})}{15 \times 10^{-6}\text{ mol/cm}^3} = \frac{4.5 \times 10^{-8}}{1.5 \times 10^{-5}}\text{ cm/s} = 3.0 \times 10^{-3}\text{ cm/s}


Important Pitfall

  • Unit Mismatch in Concentration: The concentration difference is often given in mmol/L\text{mmol/L} or mol/L\text{mol/L}. Since the area is given in cm2\text{cm}^2, volume must be in cm3\text{cm}^3 (1 L=1000 cm31\text{ L} = 1000\text{ cm}^3). Using mol/L\text{mol/L} directly without converting to mol/cm3\text{mol/cm}^3 leads to an answer off by a factor of 10310^3. Here, ΔC=15 mmol/L=15×10−3 mol/(103 cm3)=15×10−6 mol/cm3\Delta C = 15\text{ mmol/L} = 15 \times 10^{-3}\text{ mol}/(10^3\text{ cm}^3) = 15 \times 10^{-6}\text{ mol/cm}^3.

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student forgets to divide the transfer rate by the membrane area and equates flux directly to the transfer rate.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    J=dndt=1.8×10−11 mol/sJ = \frac{dn}{dt} = 1.8 \times 10^{-11}\text{ mol/s}

    Correct

    J=1Adndt=1.8×10−11 mol/s4.0×10−4 cm2=4.5×10−8 mol/(cm2⋅s)J = \frac{1}{A}\frac{dn}{dt} = \frac{1.8 \times 10^{-11}\text{ mol/s}}{4.0 \times 10^{-4}\text{ cm}^2} = 4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})

    Flux JJ is the transfer rate per unit area. You equated flux directly to the total rate of mass transfer dndt\frac{dn}{dt} without dividing by the surface area A=4.0×10−4 cm2A = 4.0 \times 10^{-4}\text{ cm}^2.

  2. Step 2

    P=JΔC=1.8×10−11 mol/s15×10−6 mol/cm3P = \frac{J}{\Delta C} = \frac{1.8 \times 10^{-11}\text{ mol/s}}{15 \times 10^{-6}\text{ mol/cm}^3}

    Correct

    P=JΔC=4.5×10−8 mol/(cm2⋅s)15×10−6 mol/cm3P = \frac{J}{\Delta C} = \frac{4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})}{15 \times 10^{-6}\text{ mol/cm}^3}

    You rearranged Fick's first law correctly to solve for P=JΔCP = \frac{J}{\Delta C}, but you substituted the incorrect value of JJ from Step 1.

  3. Step 3

    P=1.2×10−6 cm/sP = 1.2 \times 10^{-6}\text{ cm/s}

    Correct

    P=3.0×10−3 cm/sP = 3.0 \times 10^{-3}\text{ cm/s}

    Your arithmetic division was carried out correctly for your numbers, but the final value is incorrect due to the missing area term in Step 1.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly rearranged Fick's first law as P=JΔCP = \frac{J}{\Delta C}.

You correctly identified and used the concentration difference ΔC=15×10−6 mol/cm3\Delta C = 15 \times 10^{-6}\text{ mol/cm}^3.

You performed the arithmetic division 1.8×10−1115×10−6=1.2×10−6\frac{1.8 \times 10^{-11}}{15 \times 10^{-6}} = 1.2 \times 10^{-6} accurately.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Omission of Membrane Area in Flux Calculation

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Conflating solute transfer rate (amount per time, mol/s\text{mol/s}) with solute flux (amount per unit area per time, mol/(cm2⋅s)\text{mol}/(\text{cm}^2\cdot\text{s})). Checking the units of dn/dtΔC\frac{dn/dt}{\Delta C} reveals units of cm3/s\text{cm}^3/\text{s} rather than the velocity units (cm/s\text{cm/s}) required for permeability PP.

REASONING PATH
Your ACEpath teacher’s suggested approach
Distinguish Rate from Flux
  • Transfer rate is dndt\frac{dn}{dt} (in mol/s\text{mol/s}); flux is J=1AdndtJ = \frac{1}{A}\frac{dn}{dt} (in mol/(cm2⋅s)\text{mol}/(\text{cm}^2\cdot\text{s})).

  • Always divide the overall transport rate by the membrane surface area AA before substituting into J=PΔCJ = P \Delta C.

Verify Units of Permeability
  • PP has units of velocity: [P]=[J][ΔC]=mol/(cm2⋅s)mol/cm3=cm/s[P] = \frac{[J]}{[\Delta C]} = \frac{\text{mol}/(\text{cm}^2\cdot\text{s})}{\text{mol}/\text{cm}^3} = \text{cm/s}.

  • If dividing your numerator by concentration does not yield cm/s\text{cm/s}, verify whether the area term was omitted.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Calculate the true flux: J=1Adndt=1.8×10−11 mol/s4.0×10−4 cm2=4.5×10−8 mol/(cm2⋅s)J = \frac{1}{A}\frac{dn}{dt} = \frac{1.8 \times 10^{-11}\text{ mol/s}}{4.0 \times 10^{-4}\text{ cm}^2} = 4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s}).

  2. Solve for permeability: P=JΔC=4.5×10−8 mol/(cm2⋅s)15×10−6 mol/cm3=3.0×10−3 cm/sP = \frac{J}{\Delta C} = \frac{4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})}{15 \times 10^{-6}\text{ mol/cm}^3} = 3.0 \times 10^{-3}\text{ cm/s}.

Final answer

P=3.0×10−3 cm/sP = 3.0 \times 10^{-3}\text{ cm/s}

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the physical difference between total solute transport rate (mol/s\text{mol/s}) and flux (mol/(cm2⋅s)\text{mol}/(\text{cm}^2\cdot\text{s})).

  • Perform dimensional analysis on each term of Fick's first law to confirm that PP has units of cm/s\text{cm/s}.

OverviewACEpath Teacher's Diagnosis

02 The student uses the numerical concentration value in mmol/L without converting liters to cubic centimeters, causing a three-orders-of-magnitude error.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    J=1A⋅dndt=1.8×10−114.0×10−4=4.5×10−8 mol/(cm2⋅s)J = \frac{1}{A} \cdot \frac{dn}{dt} = \frac{1.8 \times 10^{-11}}{4.0 \times 10^{-4}} = 4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})

  2. Step 2

    ΔC=15 mol/L\Delta C = 15\text{ mol/L}

    Correct

    ΔC=15 mmol/L=15×10−6 mol/cm3\Delta C = 15\text{ mmol/L} = 15 \times 10^{-6}\text{ mol/cm}^3

    You wrote ΔC=15 mol/L\Delta C = 15\text{ mol/L}, omitting the milli- prefix from 15 mmol/L15\text{ mmol/L} and omitting the conversion from liters to cm3\text{cm}^3 (1 L=1000 cm31\text{ L} = 1000\text{ cm}^3).

  3. Step 3

    P=JΔC=4.5×10−815=3.0×10−9 cm/sP = \frac{J}{\Delta C} = \frac{4.5 \times 10^{-8}}{15} = 3.0 \times 10^{-9}\text{ cm/s}

    Correct

    P=JΔC=4.5×10−8 mol/(cm2⋅s)15×10−6 mol/cm3=3.0×10−3 cm/sP = \frac{J}{\Delta C} = \frac{4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})}{15 \times 10^{-6}\text{ mol/cm}^3} = 3.0 \times 10^{-3}\text{ cm/s}

    Your rearrangement P=JΔCP = \frac{J}{\Delta C} and arithmetic were carried out properly, but substituting the unscaled value 1515 produced an incorrect final answer.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly used Fick's first law to relate flux, rate of transport, and surface area.

You correctly computed the numerical value and units for solute flux JJ.

You correctly rearranged Fick's law to solve for the permeability coefficient PP.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
unit_conversion_error

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You overlooked the metric prefix 'milli-' and did not match concentration volume units (cm3\text{cm}^3) to the area units (cm2\text{cm}^2) used in the flux calculation.

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Consistency Check
  • To obtain PP in cm/s\text{cm/s} when flux JJ is in mol/(cm2⋅s)\text{mol}/(\text{cm}^2\cdot\text{s}), the concentration difference ΔC\Delta C must be expressed in mol/cm3\text{mol/cm}^3.

  • Always convert liters to cm3\text{cm}^3 using 1 L=103 cm31\text{ L} = 10^3\text{ cm}^3 and prefixes like mmol\text{mmol} to mol\text{mol} (1 mmol=10−3 mol1\text{ mmol} = 10^{-3}\text{ mol}).

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. ΔC=15 mmol/L=15×10−3 mol/103 cm3=1.5×10−5 mol/cm3\Delta C = 15\text{ mmol/L} = 15 \times 10^{-3}\text{ mol} / 10^3\text{ cm}^3 = 1.5 \times 10^{-5}\text{ mol/cm}^3

  2. P=JΔC=4.5×10−8 mol/(cm2⋅s)1.5×10−5 mol/cm3=3.0×10−3 cm/sP = \frac{J}{\Delta C} = \frac{4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})}{1.5 \times 10^{-5}\text{ mol/cm}^3} = 3.0 \times 10^{-3}\text{ cm/s}

Final answer

P=3.0×10−3 cm/sP = 3.0 \times 10^{-3}\text{ cm/s}

NEXT STEPS
Final Takeaways from Your Teacher
  • Write out all units explicitly inside the calculation to verify dimensional cancellation.

  • Practice converting concentrations between mmol/L\text{mmol/L}, mol/L\text{mol/L}, and mol/cm3\text{mol/cm}^3 before substituting them into transport equations.

OverviewACEpath Teacher's Diagnosis

03 The student multiplies the flux by the concentration difference instead of dividing by it when rearranging the permeability formula.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Incorrect
  1. Step 1

    J=(1.8×10−11)/(4.0×10−4)=4.5×10−8 mol/(cm2⋅s)J = (1.8 \times 10^{-11}) / (4.0 \times 10^{-4}) = 4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})

  2. Step 2

    P=J∗ΔC=(4.5×10−8)∗(15×10−6)P = J * \Delta C = (4.5 \times 10^{-8}) * (15 \times 10^{-6})

    Correct

    P=JΔC=4.5×10−8 mol/(cm2⋅s)15×10−6 mol/cm3P = \frac{J}{\Delta C} = \frac{4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})}{15 \times 10^{-6}\text{ mol/cm}^3}

    Starting from J=PΔCJ = P \Delta C, isolating PP requires dividing both sides by ΔC\Delta C, yielding P=JΔCP = \frac{J}{\Delta C} rather than P=J⋅ΔCP = J \cdot \Delta C.

  3. Step 3

    P=6.75×10−13 cm/sP = 6.75 \times 10^{-13}\text{ cm/s}

    Correct

    P=3.0×10−3 cm/sP = 3.0 \times 10^{-3}\text{ cm/s}

    This value resulted directly from multiplying instead of dividing by the concentration difference in the previous step.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the membrane solute flux JJ using the given rate of solute transfer and surface area.

You used compatible units for both flux and concentration.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Formula rearrangement error

no

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You treated the product form J=PΔCJ = P \Delta C as if PP were the product of flux and concentration, rather than isolating PP by dividing flux by concentration difference.

REASONING PATH
Your ACEpath teacher’s suggested approach
Isolate the Unknown Variable
  • If y=kxy = kx, then k=yxk = \frac{y}{x}.

  • Always isolate the target coefficient algebraically with the inverse operation before substituting numerical values.

Check Dimensional Consistency
  • mol/(cm2⋅s)mol/cm3=cm/s\frac{\text{mol}/(\text{cm}^2\cdot\text{s})}{\text{mol}/\text{cm}^3} = \text{cm/s}, whereas [mol/(cm2⋅s)]⋅[mol/cm3]=mol2/(cm5⋅s)[\text{mol}/(\text{cm}^2\cdot\text{s})] \cdot [\text{mol}/\text{cm}^3] = \text{mol}^2/(\text{cm}^5\cdot\text{s}).

  • Verify that your algebraic operations produce the expected physical units for the target parameter.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Rearrange Fick's first law to isolate the permeability coefficient: P=JΔCP = \frac{J}{\Delta C}.

  2. Substitute the calculated flux and concentration difference: P=4.5×10−8 mol/(cm2⋅s)15×10−6 mol/cm3P = \frac{4.5 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s})}{15 \times 10^{-6}\text{ mol/cm}^3}.

  3. Evaluate the quotient: P=3.0×10−3 cm/sP = 3.0 \times 10^{-3}\text{ cm/s}.

Final answer

P=3.0×10−3 cm/sP = 3.0 \times 10^{-3}\text{ cm/s}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice isolating variables in linear transport equations before plugging in numbers.

  • Perform dimensional analysis on your algebraic expression to ensure the units cancel to give cm/s\text{cm/s}.

Lock it in

Similar question

01

A planar lipid bilayer has an area of A=2.5×10−3 cm2A = 2.5 \times 10^{-3}\text{ cm}^2. Solute transport across the membrane occurs at dndt=5.0×10−11 mol/s\frac{dn}{dt} = 5.0 \times 10^{-11}\text{ mol/s} driven by a concentration difference ΔC=1.0×10−5 mol/cm3\Delta C = 1.0 \times 10^{-5}\text{ mol/cm}^3. Calculate the permeability coefficient PP in cm/s\text{cm/s}.

Answer

P=2.0×10−3 cm/sP = 2.0 \times 10^{-3}\text{ cm/s}. Steps: 1) J=1Adndt=5.0×10−112.5×10−3=2.0×10−8 mol/(cm2⋅s)J = \frac{1}{A}\frac{dn}{dt} = \frac{5.0 \times 10^{-11}}{2.5 \times 10^{-3}} = 2.0 \times 10^{-8}\text{ mol}/(\text{cm}^2\cdot\text{s}). 2) P=JΔC=2.0×10−81.0×10−5=2.0×10−3 cm/sP = \frac{J}{\Delta C} = \frac{2.0 \times 10^{-8}}{1.0 \times 10^{-5}} = 2.0 \times 10^{-3}\text{ cm/s}.

02

Water diffuses across an artificial vesicle membrane of surface area A=8.0×10−4 cm2A = 8.0 \times 10^{-4}\text{ cm}^2. The permeability coefficient is P=4.0×10−3 cm/sP = 4.0 \times 10^{-3}\text{ cm/s} and the concentration difference across the membrane is ΔC=2.5×10−5 mol/cm3\Delta C = 2.5 \times 10^{-5}\text{ mol/cm}^3. Calculate the total rate of mass transfer dndt\frac{dn}{dt} in mol/s\text{mol/s}.

Answer

dndt=8.0×10−11 mol/s\frac{dn}{dt} = 8.0 \times 10^{-11}\text{ mol/s}. Steps: 1) J=PΔC=(4.0×10−3)(2.5×10−5)=1.0×10−7 mol/(cm2⋅s)J = P \Delta C = (4.0 \times 10^{-3})(2.5 \times 10^{-5}) = 1.0 \times 10^{-7}\text{ mol}/(\text{cm}^2\cdot\text{s}). 2) dndt=J⋅A=(1.0×10−7)(8.0×10−4)=8.0×10−11 mol/s\frac{dn}{dt} = J \cdot A = (1.0 \times 10^{-7})(8.0 \times 10^{-4}) = 8.0 \times 10^{-11}\text{ mol/s}.

03

In a cell culture experiment, the diffusion rate of urea across a monolayer is dndt=3.6×10−10 mol/s\frac{dn}{dt} = 3.6 \times 10^{-10}\text{ mol/s}. The measured concentration difference is ΔC=12 mmol/L\Delta C = 12\text{ mmol/L}. If the permeability coefficient of urea is P=1.5×10−4 cm/sP = 1.5 \times 10^{-4}\text{ cm/s}, determine the total surface area AA of the monolayer in cm2\text{cm}^2.

Answer

A=0.20 cm2A = 0.20\text{ cm}^2. Steps: 1) Convert concentration: ΔC=12 mmol/L=12×10−6 mol/cm3\Delta C = 12\text{ mmol/L} = 12 \times 10^{-6}\text{ mol/cm}^3. 2) Compute flux: J=PΔC=(1.5×10−4)(1.2×10−5)=1.8×10−9 mol/(cm2⋅s)J = P \Delta C = (1.5 \times 10^{-4})(1.2 \times 10^{-5}) = 1.8 \times 10^{-9}\text{ mol}/(\text{cm}^2\cdot\text{s}). 3) Solve for area: A=dn/dtJ=3.6×10−101.8×10−9=0.20 cm2A = \frac{dn/dt}{J} = \frac{3.6 \times 10^{-10}}{1.8 \times 10^{-9}} = 0.20\text{ cm}^2.

Loading workspace…