Resources

An environmental biology team performs an indoor air-quality assay using a single-stage Andersen cascade impactor operating at a calibrated airflow rate of Q=28.3 L/minQ = 28.3\,\text{L}/\text{min} for a total sampling time of t=12.0 mint = 12.0\,\text{min}. Fungal spores are impacted directly onto Sabouraud dextrose agar plates. After incubation at 25.0∘C25.0^\circ\text{C} for 55 days, colony-forming units (CFU) are enumerated under a dissecting microscope. The raw colony count is 168168 colonies, which corresponds to a positive-hole corrected count of Ncorr=214N_{\text{corr}} = 214 viable airborne propagules. (a) Calculate the total volume of air sampled in cubic meters (m3\text{m}^3). (b) Calculate the airborne fungal concentration in CFU/m3\text{CFU}/\text{m}^3. (c) Microscopic inspection reveals conidiophores bearing chains of pigmented, unbranched conidia arising from phialides on a swollen terminal vesicle. Identify the fungal genus matching this diagnostic morphology.

Answer and steps

Final answer

(a) Total volume sampled V=28.3 L/min×12.0 min=339.6 L=0.3396 m3≈0.340 m3V = 28.3\,\text{L}/\text{min} \times 12.0\,\text{min} = 339.6\,\text{L} = 0.3396\,\text{m}^3 \approx 0.340\,\text{m}^3. (b) Airborne fungal concentration =214 CFU0.3396 m3=630 CFU/m3= \frac{214\,\text{CFU}}{0.3396\,\text{m}^3} = 630\,\text{CFU}/\text{m}^3. (c) The diagnostic morphological characteristics (conidiophores with swollen apical vesicles bearing phialides that produce unbranched chains of conidiospores) identify the genus Aspergillus.

Steps

Part (a): Total Volume of Air Sampled

  1. Calculate total volume in liters (L\text{L}):
    The total volume of air sampled, VV, is the product of the volumetric flow rate QQ and the sampling duration tt: V=Q⋅t=28.3 L/min×12.0 min=339.6 LV = Q \cdot t = 28.3\,\text{L/min} \times 12.0\,\text{min} = 339.6\,\text{L}
  2. Convert liters to cubic meters (m3\text{m}^3):
    Since 1 m3=1000 L1\,\text{m}^3 = 1000\,\text{L}: V=339.6 L1000 L/m3=0.3396 m3≈0.340 m3V = \frac{339.6\,\text{L}}{1000\,\text{L/m}^3} = 0.3396\,\text{m}^3 \approx 0.340\,\text{m}^3

Part (b): Airborne Fungal Concentration

  1. Apply the positive-hole corrected count:
    In single-stage sieve impactors, multiple viable spores can pass through the same orifice and coalesce into a single visible colony on the agar. Therefore, air-quality protocols require using the positive-hole corrected count (Ncorr=214 CFUN_{\text{corr}} = 214\,\text{CFU}) rather than the unadjusted raw count (168 CFU168\,\text{CFU}).
  2. Calculate the concentration:
    Concentration=NcorrV=214 CFU0.3396 m3≈630.15 CFU/m3\text{Concentration} = \frac{N_{\text{corr}}}{V} = \frac{214\,\text{CFU}}{0.3396\,\text{m}^3} \approx 630.15\,\text{CFU/m}^3 Rounding to three significant figures gives: Concentration≈630 CFU/m3\text{Concentration} \approx 630\,\text{CFU/m}^3

Part (c): Fungal Identification from Diagnostic Morphology

  1. Analyze morphological features:

    • Conidiophore: An erect, non-septate stalk arising from a foot cell.
    • Terminal vesicle: The apex of the conidiophore enlarges into a distinctive globular or hemispherical swelling.
    • Phialides: Flask-shaped conidiogenous cells that radiate directly (uniseriate) or from supporting cells called metulae (biseriate) across the surface of the vesicle.
    • Conidia: Unbranched basipetal chains of asexual spores produced from the tips of the phialides.
  2. Taxonomic identification:
    This vesicle-and-radiating-phialide arrangement resembles an "aspergillum" (a holy-water sprinkler) and is the definitive hallmark of the ascomycete genus Aspergillus.

    (Note: By contrast, the related genus Penicillium lacks a swollen apical vesicle, instead forming a branched, brush-like conidiophore called a penicillus).

Typical errors

OverviewACEpath Teacher's Diagnosis

01 The student uses the uncorrected raw colony count rather than the positive-hole corrected count to calculate the airborne fungal concentration.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    V=28.3 L/min×12.0 min=339.6 L  ⟹  V=339.6/1000=0.3396 m3V = 28.3\,\text{L/min} \times 12.0\,\text{min} = 339.6\,\text{L} \implies V = 339.6 / 1000 = 0.3396\,\text{m}^3

  2. Step 2

    C=168 CFU/0.3396 m3  ⟹  C=494.7 CFU/m3C = 168\,\text{CFU} / 0.3396\,\text{m}^3 \implies C = 494.7\,\text{CFU/m}^3

    Correct

    C=NcorrV=214 CFU0.3396 m3≈630 CFU/m3C = \frac{N_{\text{corr}}}{V} = \frac{214\,\text{CFU}}{0.3396\,\text{m}^3} \approx 630\,\text{CFU/m}^3

    You divided the raw colony count (168 CFU168\,\text{CFU}) by the volume instead of using the positive-hole corrected count (Ncorr=214 CFUN_{\text{corr}} = 214\,\text{CFU}). Sieve impactors can deposit multiple viable spores through the same hole, so the statistical correction table accounts for colony overlap.

  3. Step 3

    Aspergillus\textit{Aspergillus}

WHAT YOU DID WELL
Compliments from Your Teacher

You accurately calculated the total air volume sampled and converted it from liters to cubic meters.

You correctly matched the diagnostic microscopic morphology to the genus Aspergillus.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Uncorrected impactor count used

You selected the raw observed count (168168) instead of the supplied positive-hole corrected count (214214).

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Overlooking the biological and physical principle of positive-hole correction in sieve impaction, where multiple viable airborne propagules can enter through the same impactor hole and coalesce into a single colony, leading to an underestimate of viable airborne concentrations unless corrected.

REASONING PATH
Your ACEpath teacher’s suggested approach
Positive-Hole Adjustment
  • In multi-orifice sieve impactors (like the Andersen sampler), the airborne concentration must be computed using NcorrN_{\text{corr}} rather than raw colony count NrawN_{\text{raw}}.

  • Always check whether a positive-hole corrected count (NcorrN_{\text{corr}}) is provided or required before dividing by sampled air volume.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Identify the positive-hole corrected viable count: Ncorr=214 CFUN_{\text{corr}} = 214\,\text{CFU}.

  2. Divide by the sampled volume: C=214 CFU0.3396 m3≈630.15 CFU/m3C = \frac{214\,\text{CFU}}{0.3396\,\text{m}^3} \approx 630.15\,\text{CFU/m}^3.

  3. Round to three significant figures: C≈630 CFU/m3C \approx 630\,\text{CFU/m}^3.

Final answer

630 CFU/m3630\,\text{CFU/m}^3

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the operating principles of Andersen cascade impactors, specifically why coincident impaction requires statistical positive-hole correction tables.

  • Practice bioaerosol concentration calculations using both raw and adjusted counts to reinforce using corrected values.

OverviewACEpath Teacher's Diagnosis

02 The student inverts the unit conversion between liters and cubic meters by multiplying by 1000 instead of dividing.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    V=28.3 L/min×12.0 min=339.6 LV = 28.3\,\text{L/min} \times 12.0\,\text{min} = 339.6\,\text{L}

  2. Step 2

    V=339.6×1000=339600 m3V = 339.6 \times 1000 = 339600\,\text{m}^3

    Correct

    V=339.6 L1000 L/m3=0.3396 m3≈0.340 m3V = \frac{339.6\,\text{L}}{1000\,\text{L/m}^3} = 0.3396\,\text{m}^3 \approx 0.340\,\text{m}^3

    Because 1 m3=1000 L1\,\text{m}^3 = 1000\,\text{L}, converting from a smaller unit (liters) to a larger unit (cubic meters) requires dividing by 10001000, not multiplying.

  3. Step 3

    C=214 CFU/339600 m3  ⟹  C=0.00063 CFU/m3C = 214\,\text{CFU} / 339600\,\text{m}^3 \implies C = 0.00063\,\text{CFU/m}^3

    Correct

    C=214 CFU0.3396 m3≈630 CFU/m3C = \frac{214\,\text{CFU}}{0.3396\,\text{m}^3} \approx 630\,\text{CFU/m}^3

    You correctly chose the corrected count (214 CFU214\,\text{CFU}) and used the formula C=N/VC = N/V, but your numerical result was affected by the volume conversion error in the previous step.

  4. Step 4

    Aspergillus\textit{Aspergillus}

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the total air volume in liters using the flow rate and duration.

You used the positive-hole corrected count rather than the unadjusted colony count to determine airborne concentration.

You correctly diagnosed the genus Aspergillus based on the diagnostic terminal vesicle and conidial structure.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Inverted metric volume conversion factor

You set up the unit conversion by multiplying by 10001000 instead of dividing by 10001000.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

Confusing the direction of dimensional analysis when converting between liters and cubic meters (1 m3=103 L1\,\text{m}^3 = 10^3\,\text{L}, so 1 L=10−3 m31\,\text{L} = 10^{-3}\,\text{m}^3).

REASONING PATH
Your ACEpath teacher’s suggested approach
Unit Size Check
  • A cubic meter is a large volume (1 m×1 m×1 m=1000 L1\,\text{m} \times 1\,\text{m} \times 1\,\text{m} = 1000\,\text{L}).

  • When converting from liters to cubic meters, the numerical value must become smaller: divide by 10001000.

Dimensional Cancellation
  • m3=L×(1 m31000 L)\text{m}^3 = \text{L} \times \left(\frac{1\,\text{m}^3}{1000\,\text{L}}\right)

  • Write out conversion fractions explicitly with units canceling across the numerator and denominator.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. V=339.6 L1000 L/m3=0.3396 m3V = \frac{339.6\,\text{L}}{1000\,\text{L/m}^3} = 0.3396\,\text{m}^3

  2. Airborne fungal concentration C=214 CFU0.3396 m3≈630.15 CFU/m3≈630 CFU/m3C = \frac{214\,\text{CFU}}{0.3396\,\text{m}^3} \approx 630.15\,\text{CFU/m}^3 \approx 630\,\text{CFU/m}^3

  3. Taxonomic identification remains Aspergillus\textit{Aspergillus}.

Final answer

(a) 0.340 m30.340\,\text{m}^3 (or 0.3396 m30.3396\,\text{m}^3); (b) 630 CFU/m3630\,\text{CFU/m}^3; (c) Aspergillus\textit{Aspergillus}

NEXT STEPS
Final Takeaways from Your Teacher
  • Practice converting between liters and cubic meters by explicitly writing the unit fraction 1 m31000 L\frac{1\,\text{m}^3}{1000\,\text{L}}.

  • Perform a sanity check on final concentration values: indoor air typically ranges from tens to thousands of CFU/m3\text{CFU/m}^3, so 0.00063 CFU/m30.00063\,\text{CFU/m}^3 is an immediate clue that the denominator is too large.

OverviewACEpath Teacher's Diagnosis

03 The student confuses the vesicle-based conidial arrangement of Aspergillus with the brush-like branching metulae structure of Penicillium.

Sample Student Work

Reviewed by ACEpath Teacher
Step-by-Step Review
Walk Through It with Your Teacher
Partially correct
  1. Step 1

    V=28.3 L/min×12.0 min=339.6 L  ⟹  V=339.61000=0.3396 m3V = 28.3\,\text{L/min} \times 12.0\,\text{min} = 339.6\,\text{L} \implies V = \frac{339.6}{1000} = 0.3396\,\text{m}^3

  2. Step 2

    C=214 CFU0.3396 m3  ⟹  C=630.2 CFU/m3C = \frac{214\,\text{CFU}}{0.3396\,\text{m}^3} \implies C = 630.2\,\text{CFU/m}^3

  3. Step 3

    Penicillium\text{Penicillium}

    Correct

    Aspergillus\textit{Aspergillus}

    The presence of a swollen terminal vesicle bearing phialides that radiate conidial chains defines Aspergillus. In contrast, Penicillium lacks a terminal vesicle and instead forms a branched, brush-like conidiophore.

WHAT YOU DID WELL
Compliments from Your Teacher

You correctly calculated the total air volume sampled by multiplying the volumetric flow rate by time and converting liters to cubic meters.

You correctly identified that the positive-hole corrected count must be used to calculate airborne fungal concentration.

THE ERROR
Where Your ACEpath Teacher Spotted the Mistake
Conidiophore morphology confusion

None. Your numerical calculations and unit conversions were completely accurate.

WHY IT HAPPENED
ACEpath Teacher's Diagnosis

You confused the vesicle-based conidiophore morphology of Aspergillus with the brush-like branching metulae of Penicillium.

REASONING PATH
Your ACEpath teacher’s suggested approach
Diagnostic conidiophore structure
  • A swollen apical vesicle supporting phialides indicates Aspergillus; a branched, brush-like arrangement without a vesicle indicates Penicillium.

  • Look specifically for whether the conidiophore apex expands into a globose vesicle or branches directly into metulae and phialides.

CORRECTED PATH
ACEpath Teacher's Demonstration
  1. Re-read the anatomical description: 'conidiophores bearing chains of pigmented, unbranched conidia arising from phialides on a swollen terminal vesicle'.

  2. Note that the swollen apical vesicle is the hallmark of Aspergillus (resembling an aspergillum sprinkler).

  3. Conclude that the matching genus is Aspergillus.

Final answer

Aspergillus

NEXT STEPS
Final Takeaways from Your Teacher
  • Review the distinct asexual reproductive structures of common airborne ascomycetes, focusing on Aspergillus (vesicular head) versus Penicillium (branched brush).

  • Practice identifying microscopic structures by drawing and labeling the conidiophore, vesicle, metulae, phialides, and conidia.

Lock it in

Similar question

01

An air sampler operates at 28.3 L/min28.3\,\text{L/min} for 10.0 min10.0\,\text{min}. The agar plate yields 142142 raw colonies, corresponding to a positive-hole corrected count of 175 CFU175\,\text{CFU}. Calculate the airborne microbial concentration in CFU/m3\text{CFU/m}^3 rounded to three significant figures.

Answer

618 CFU/m3618\,\text{CFU/m}^3. Total volume V=28.3 L/min×10.0 min=283 L=0.283 m3V = 28.3\,\text{L/min} \times 10.0\,\text{min} = 283\,\text{L} = 0.283\,\text{m}^3. Concentration =175 CFU0.283 m3≈618.37 CFU/m3≈618 CFU/m3= \frac{175\,\text{CFU}}{0.283\,\text{m}^3} \approx 618.37\,\text{CFU/m}^3 \approx 618\,\text{CFU/m}^3.

02

A bioaerosol investigation records an airborne fungal concentration of 850 CFU/m3850\,\text{CFU/m}^3 from a 5.00 min5.00\,\text{min} sample taken at 28.3 L/min28.3\,\text{L/min}. (a) Find the positive-hole corrected count NcorrN_{\text{corr}}. (b) Explain whether the observed raw colony count on the agar plate was greater than, equal to, or less than NcorrN_{\text{corr}}.

Answer

(a) Ncorr=120 CFUN_{\text{corr}} = 120\,\text{CFU}. Volume V=28.3 L/min×5.00 min=141.5 L=0.1415 m3V = 28.3\,\text{L/min} \times 5.00\,\text{min} = 141.5\,\text{L} = 0.1415\,\text{m}^3. Ncorr=850 CFU/m3×0.1415 m3=120.275≈120 CFUN_{\text{corr}} = 850\,\text{CFU/m}^3 \times 0.1415\,\text{m}^3 = 120.275 \approx 120\,\text{CFU}. (b) The raw colony count was less than NcorrN_{\text{corr}} because multiple spores impacting through the same hole merge into single visible colonies.

03

An environmental laboratory compares two fungal isolates: Isolate A exhibits conidiophores ending in a swollen terminal vesicle with radiating phialides producing chains of conidia. Isolate B exhibits branched, brush-like conidiophores (penicilli) lacking a swollen vesicle. Identify both genera and state which phylum of Fungi both belong to.

Answer

Isolate A is Aspergillus; Isolate B is Penicillium. Both genera belong to the phylum Ascomycota.